MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 30 of 48  Not logged in MUST2
Status ExpNbr Date Author Type Category Target-Source Subject
Fixede755 Thu Jun 21 08:30:48 2018 shumpei, daisukeRUNGeneral3-alphaRUN0040 8 MeV source run with liquid hydrogen
RUN 0040. started 7:23 am

8 MeV source was set upstream at 0 degrees to confirm that the target is filled with liquid. The target has been cooled since 4 pm yesterday. From the record of temperatures and pressure, it is likely that hydrogen stays in the liquid phase. It has yet to be confirmed if hydrogen inside the cell is still in liquid or partially evaporated.

target cell 18.180 K
heat shield 114.62 K
H2 gas -0.23 atm
M2C 3.09e-6 mbar

There are events in T5 and T6, but without any clusters formed at an energy of 250 ADC channels (expected energy for alpha particles that traverse hydrogen gas). Need more analysis to conclude.
Attachment 1: 2018-06-21_run0040_04.png
2018-06-21_run0040_04.png
Attachment 2: 2018-06-21_run0040_03.png
2018-06-21_run0040_03.png
Attachment 3: 2018-06-21_run0040_02.png
2018-06-21_run0040_02.png
Attachment 4: 2018-06-21_run0040_01.png
2018-06-21_run0040_01.png
Fixede755 Thu Jun 21 09:16:01 2018 KitamuraTARGETHardwareN/AVapor pressure
Vapor pressures of isobutane and CF4. The paramateres of the Antoine equation were taken from the following NIST
pages.

Isobutane: https://webbook.nist.gov/cgi/cbook.cgi?ID=C75285&Mask=4&Type=ANTOINE&Plot=on
CF4: https://webbook.nist.gov/cgi/cbook.cgi?ID=C75730&Mask=4&Type=ANTOINE&Plot=on

MODIFIED ATTACHMENT FILES: vertical axes were fixed
Attachment 1: isobutane.png
isobutane.png
Attachment 2: cf4.png
cf4.png
Fixede755 Thu Jun 21 16:08:32 2018 ValerianMUST2HardwareN/ARun 3045 : Calimero T1-4 X
run 3045 :
start @ 15h35
stop @ 15h59
T1-4 X
Attachment 1: Calimero_T14X.png
Calimero_T14X.png
Pinnede755 Thu Jun 21 17:07:14 2018 ValerianMUST2GeneralN/Arun 3046 : Calimero T1-4Y
run 3046 : Calimero T1-4Y
start @ 16h28
stop @ 16h53
Attachment 1: Calimero_T14Y.png
Calimero_T14Y.png
Fixede755 Thu Jun 21 18:52:42 2018 takeshiTARGETHardwareN/Atarget temperature
Here I attached the temperature graph which is daisuke discussed at the meeting.
Both the heat shield (blue line) and the cell (green) increase after the minimum at 8 hours.
They had a second minimum at 21 hours and now they are increasing.
Attachment 1: entire.png
entire.png
Attachment 2: heatshield.png
heatshield.png
Attachment 3: cell.png
cell.png
Fixede755 Fri Jun 22 03:11:51 2018 takeshiVACUUMHardwareN/Athe vacuum pressure and the target temperature
We suspect the impurity of the vacuum causes the rebound behavior of the target temperature.
Here is the data of the vacuum level v.s. the target temperature as it increasing.
As Daisuke explained at the meeting, we are monitoring two point as temperature reference, the cell (A) and the heat shield (E).
The detail discussion is still ongoing.
Attachment 1: M2CvsE.png
M2CvsE.png
Attachment 2: M2CvsA.png
M2CvsA.png
Fixede755 Fri Jun 22 11:14:01 2018 Valerian Pierre Adrien Fred FairouzMUST2GeneralN/Arun 3061 Calimero T5-8X
run 3061 Calimero T5-8X
Attachment 1: Calimero_T56X.png
Calimero_T56X.png
Fixede755 Fri Jun 22 13:06:29 2018 daisukeMECHHardwareN/AAlpha source ladder instruction
Instruction to translate and rotate the ladder for the alpha sources (by Vincent).
Attachment 1: Photos_porte_source_E755_et_E738.pdf
Photos_porte_source_E755_et_E738.pdf
Fixede755 Fri Jun 22 13:22:19 2018 daisukeBEAMSocialN/ABeam time schedule
Attachment 1: Planning_Faisceaux_2018_run2.1.0.pdf
Planning_Faisceaux_2018_run2.1.0.pdf Planning_Faisceaux_2018_run2.1.0.pdf Planning_Faisceaux_2018_run2.1.0.pdf Planning_Faisceaux_2018_run2.1.0.pdf
Fixede755 Fri Jun 22 13:45:22 2018 takeshiTARGETHardwareN/Atarget temperature status
I would report the temperature log of the target up to now.
We started cooling the target at 2:21 last night.
The attached file is the temperature graph. The black lines are the today and the other colors are for reference. The thicker line is the heat shield and the thiner line is the cell. Note the time offset is adjusted by about 1 hours, to match the blue reference line (Wednesday data).
Both the cell and the heat shield show the same behavior as Wednesday up to now.
Attachment 1: tamperature2206.png
tamperature2206.png
Attachment 2: heatshield2206.png
heatshield2206.png
Attachment 3: cell2206.png
cell2206.png
Fixede755 Fri Jun 22 16:57:27 2018 daisukeOTHERSocialN/AWho is in GANIL?
https://docs.google.com/spreadsheets/d/1jyfw2LT3RGfDY4bcN-9zepZoe2uE89b5CnF4tXzqzj8/edit#gid=0
Fixede755 Fri Jun 22 21:29:05 2018 Pierre Fairouz Adrien ValerianCATSGeneralN/AMask reconstruction
Mask reconstruction after adding the correction shift for CATS.
CATS1X = +1.2
CATS1Y = -0.1
CATS2X = 2.0
CATS2Y = -0.2
Attachment 1: mask1.pdf
mask1.pdf
Attachment 2: mask2.pdf
mask2.pdf
Fixede755 Fri Jun 22 22:12:43 2018 daisukeMECHHardwareN/Apositions, geometry and dimensions
Attachment 1: 2018-06-13_e738_setup.pdf
2018-06-13_e738_setup.pdf 2018-06-13_e738_setup.pdf 2018-06-13_e738_setup.pdf 2018-06-13_e738_setup.pdf 2018-06-13_e738_setup.pdf 2018-06-13_e738_setup.pdf 2018-06-13_e738_setup.pdf 2018-06-13_e738_setup.pdf
Fixede755 Fri Jun 22 22:14:30 2018 daisukeMECHHardwareN/AHow to open the gate valve
Attachment 1: Procedure_d'ouverture_de_vanne_d'isolement.pdf
Procedure_d'ouverture_de_vanne_d'isolement.pdf
Pinnede755 Fri Jun 22 22:15:45 2018 daisukeMECHHardwareN/AGeometrical survey report
Attachment 1: E755_Listing_DSSD_X_Y_Z_repère_géomètre.xlsx
Attachment 2: STP-2018-E071_D6_E755_Sorlin_Suzuki.pdf
STP-2018-E071_D6_E755_Sorlin_Suzuki.pdf STP-2018-E071_D6_E755_Sorlin_Suzuki.pdf STP-2018-E071_D6_E755_Sorlin_Suzuki.pdf STP-2018-E071_D6_E755_Sorlin_Suzuki.pdf
Attachment 3: E755_Listing_DSSD_X_Y_Z.pdf
E755_Listing_DSSD_X_Y_Z.pdf
Fixede755 Sat Jun 23 00:39:33 2018 takeshiTARGETHardwareN/Atarget temperature
Here is the target temperature up to now. The black lines are today, and bule lines are reference.
The thicker line is for the heat shield and the thinner is for the cell.
Once we reached flat region at 15 hours, and but got a sudden increase of cell temperature at 19.5 hours.
Attachment 1: temperature2306.png
temperature2306.png
Attachment 2: heatshield2306.png
heatshield2306.png
Attachment 3: cell2306.png
cell2306.png
Fixede755 Sat Jun 23 00:47:19 2018 Pierre ValerianCATSGeneralN/ANEW GOOD mask reconstruction
New shift for CATS after fixing Z position of CATS detectors.

ConfigCATS

ZPROJ -824
ZPROJ -1332

SHIFT_CATS CATS1X -2.3
SHIFT_CATS CATS1Y -3.9
SHIFT_CATS CATS2X 4.5
SHIFT_CATS CATS2Y -2.2
Attachment 1: mask1.pdf
mask1.pdf
Attachment 2: mask2.pdf
mask2.pdf
Fixede755 Sat Jun 23 01:55:34 2018 LouisBEAMGeneralCH2Beam tunning
Beam was tunned around 1am to center the beam on the target. On the picture, up is after tunning and down is before tunning
Attachment 1: beam_tunnig23_06_1h_24m.png
beam_tunnig23_06_1h_24m.png
Fixede755 Sat Jun 23 02:28:03 2018 daisuke, louis, jean-charlesRUNSoftwareN/ARUN 63 (40Ca + liq. H) scalers and histograms
Attachment 1: run_0063_tac.png
run_0063_tac.png
Attachment 2: run_0063_must2_impact.png
run_0063_must2_impact.png
Attachment 3: run_0063_mmye5-8.png
run_0063_mmye5-8.png
Attachment 4: run_0063_mmye1-4.png
run_0063_mmye1-4.png
Attachment 5: run_0063_mmxe5-8.png
run_0063_mmxe5-8.png
Attachment 6: run_0063_mmxe1-4.png
run_0063_mmxe1-4.png
Attachment 7: run_0063_cats.png
run_0063_cats.png
Attachment 8: run_0063_scaler_gmt.png
run_0063_scaler_gmt.png
Attachment 9: run_0063_scaler_nobeam.png
run_0063_scaler_nobeam.png
Attachment 10: run_0063_scaler.png
run_0063_scaler.png
Fixede755 Sat Jun 23 04:16:03 2018 LouisOFFLINEGeneralCH2deltaE E
here a plot of energy loss in DSSD in function of energy in CsI. One can distinguish proton and alpha. Energy calibration of the CsI is needed to identify clearly the tritons
Attachment 1: dEE_noCalib_run0063.jpg
dEE_noCalib_run0063.jpg