Fixed, e744, Fri May 18 13:28:24 2018, Ruxandra, EXL-PPT, Software, 60Co, new calibration
|
The new calibration coefficients for the PPT detector (run 339): E=0.526*ch+32.57 |
Fixed, , Fri May 18 15:17:19 2018, Megumi and Louis, OTHER, Hardware, , TAC range setting and time calibration
|
1 mm-cats 1us
2 mm-hf 200ns
3 mm-exl 1us
4 mm-ppt 1us
5 cats-hf 200ns
6 exl-cats 1us
7 ppt-cats 1us
8 mm-mcp 1us
9 mm-hfv 200ns
10 mcp-hf 200ns
time calibrator setting
period 0.02us
range 1.28us
run340 for test
run341 for calibration of mm-cats start
run343 for calibration of mm-hf
run344 for calibration of mm-exl, mm-ppt, mm-mcp, mm-hf, mcp-hfv
added on 21/05/2018
we found validation point was missing for some channels
run349 for calibraion cats_hf
run350 for calibration ppt_cats
run351 for calibraion cats_hf again
run352 for calibration exl_cats
calibration parameter (in ns)
1 mm-cats 0.0495255
2 mm-hf 0.0102974
3 mm-exl 0.0500575
4 mm-ppt 0.0510095
5 cats-hf 0.010322
6 exl-cats 0.0547923
7 ppt-cats 0.051581
8 mm-mcp 0.0507524
9 mm-hfv 0.0107085
10 mcp-hf 0.01041 |
Fixed, e744, Fri May 18 17:38:21 2018, Francois and Pedja, OTHER, Hardware, , translator nim to ecl
|
There was a problem with the scalers, not all of them were working. After several tests, we changed the electronic module, from Lecroy ECl-NIM-ECL to module LPC translator NIM-ECL. We checked all channels, they work. For a while channel N°4 was not working. We changed the nim cable, it works now. |
Fixed, e744, Sun May 20 18:53:44 2018, iulian Jaromir Cristina, EXL-PPT, General, N/A, Run #347 Background run EXL & PPT triggers  
|
Run #347
Background run EXL & PPT triggers
start @18h53 20/05
stop @11h14 21/05 |
Fixed, e744, Mon May 21 11:42:16 2018, iulian cristina, MUST2, Software, N/A, run 348 test comunication with Must. Pulser T1 channel 11
|
|
Fixed, e744, Tue May 22 10:44:30 2018, iulian Fairouz Valerie, MUST2, Software, N/A, Run #353 Calimero T1-T4 strips X
|
Started run #353
Calimero T1-T4 strips X
Time Calibrator 320 ns ; period 20 ns |
Fixed, e744, Tue May 22 11:37:50 2018, Valérie, MUST2, Software, N/A, calimero config GECO   
|
Calimero T1-T4 strips X
Time Calibrator 640 ns ; period 20 ns |
Fixed, e744, Tue May 22 11:59:06 2018, Valérie, MUST2, Software, N/A, Calimero config GECO 8x
|
|
Fixed, e744, Tue May 22 12:09:27 2018, iulian Fairouz Valerie, MUST2, Software, N/A, Run #354 Calimero T1-T4 strips X    
|
Started run #353
Calimero T1-T4 strips X
Time Calibrator 640 ns ; period 20 ns |
Fixed, e744, Tue May 22 12:10:27 2018, iulian Fairouz Valerie, MUST2, Software, N/A, Run #355 Calimero T1-T4 strips Y
|
Started run #353
Calimero T1-T4 strips Y
Time Calibrator 640 ns ; period 20 ns |
Fixed, e744, Tue May 22 13:40:03 2018, Fairouz Valerie, MUST2, Software, N/A, Run #356 Calimero T1-T4 strips Y
|
Run #356
Time Calibrator Calimero stripYT T1to T4 640ns period 20ns |
Fixed, e744, Tue May 22 19:36:50 2018, Fairouz, Valérie, MUST2, Software, N/A, Run #359 Calimero T1-T4 strips X 8x
|
Run #359
amplitude of the gene is now set to 10 MeV
Time Calibrator Calimero stripsX T1to T4 640ns period 20ns |
Fixed, e744, Tue May 22 19:40:48 2018, Valérie , MUST2, General, N/A, snapshots for steps in Calimero calibration 11x
|
|
Fixed, e744, Tue May 22 20:06:15 2018, Fairouz, Valerie, edited by Iulian Megumi, MUST2, Software, N/A, Run #360 Calimero T1-T4 strips Y
|
Started run #360
calimero stripsYT T1 to T4 640 ns; period 20 ns
amplitude pulser 10 MeV
There was a problem on T2 as the channel 2 on GMT MASTER was set on TTL. |
Fixed, e744, Tue May 22 21:43:31 2018, iulian & megumi, MUST2, Software, N/A, run 361
|
run 361
start 20h38
stop 21h41 |
Fixed, e744, Tue May 22 21:57:51 2018, iulian & megumi, MUST2, Software, N/A, Run #362 Calimero T1-T4 strips X again with solution 
|
Changed the Thresholds on T4. No longer double peaks...
I guess there is some noise on the T4 and he triggers on the noise from time to time => double peaks
Also T1-T3 have have strip 16 near pidestal who is counting a lot (red) |
Fixed, e744, Tue May 22 22:33:09 2018, e744, MUST2, Software, N/A, Run #363 Calimero T1-T4 strips X again with threshold at 50% (same as 40%)
|
Run #363
NB: Thresholds are the ones on the pulser amplitude to inject the signal (Calimero Pulser interface on Geco). see snapshots on the Calimero summary.
Calimero with 50% thresholds on T4. Same spectra as with the thresholds @40%. I think T4 is triggering on cross-talk, so when the thresholds it's high it's ok. |
Fixed, e744, Tue May 22 22:50:47 2018, e744, MUST2, Software, N/A, Run #365 Calimero strips Y T1-T4 100% Threshold
|
Run #365
Calimero strips Y T1-T4
100% threshold on T4
Something is wrong with the masking?! |
Fixed, e744, Wed May 23 00:30:34 2018, e744, EXL-PPT, General, N/A, RUN #402, EXL PPT trigger
|
RUN #402
start exl ppt run for checking coincidence
exl ch 17 put in to adc2 ch 32 |
Fixed, e744, Wed May 23 10:52:28 2018, Valérie, EXL-PPT, General, N/A, RUN #405, EXL PPT trigger   
|
RUN #405
start exl ppt run for checking coincidence
|
|