Pinnede744 Mon May 21 11:26:55 2018 iulian cristinaOTHERHardwareN/Aerror stop run/ run still going
After stopping run 347, the narval looks like everything was stopped (blue ready), but I still had FAGs, VALs, and the leds on the GMT were blinking. MUVI was in ready state (leds green - red).
Attachment 1: error_Narval.png
error_Narval.png
Attachment 2: error_DAS1.png
error_DAS1.png
Fixede744 Mon May 21 11:42:16 2018 iulian cristinaMUST2SoftwareN/Arun 348 test comunication with Must. Pulser T1 channel 11
Attachment 1: MUST2_Pulser_T1_E11_run348.png
MUST2_Pulser_T1_E11_run348.png
Fixede744 Tue May 22 10:44:30 2018 iulian Fairouz ValerieMUST2SoftwareN/ARun #353 Calimero T1-T4 strips X
Started run #353
Calimero T1-T4 strips X
Time Calibrator 320 ns ; period 20 ns
Fixede744 Tue May 22 11:37:50 2018 ValérieMUST2SoftwareN/Acalimero config GECO

Calimero T1-T4 strips X
Time Calibrator 640 ns ; period 20 ns
Attachment 1: PlotTel1strxT101calimOk.png
PlotTel1strxT101calimOk.png
Attachment 2: PlotXTel1tXT88Probmate.png
PlotXTel1tXT88Probmate.png
Attachment 3: PlotXTel1to4XTProbmate.png
PlotXTel1to4XTProbmate.png
Attachment 4: PlotXTel1to4XTcalimero.png
PlotXTel1to4XTcalimero.png
Fixede744 Tue May 22 11:59:06 2018 ValérieMUST2SoftwareN/A Calimero config GECO
Attachment 1: configGecotelstrYTcalimero.png
configGecotelstrYTcalimero.png
Attachment 2: StartCalimero6%.png
StartCalimero6%.png
Attachment 3: ConfigGecostartCalimero.png
ConfigGecostartCalimero.png
Attachment 4: startRccbrefCalim.png
startRccbrefCalim.png
Attachment 5: RccbeforeStartcalimero.png
RccbeforeStartcalimero.png
Attachment 6: ConfigGecobeforeStart.png
ConfigGecobeforeStart.png
Attachment 7: NarvalConfigGecoCal.png
NarvalConfigGecoCal.png
Attachment 8: MUST2_calimGecoTX.png
MUST2_calimGecoTX.png
Fixede744 Tue May 22 12:09:27 2018 iulian Fairouz ValerieMUST2SoftwareN/ARun #354 Calimero T1-T4 strips X
Started run #353
Calimero T1-T4 strips X
Time Calibrator 640 ns ; period 20 ns
Attachment 1: PlotXTel1tXT88Probmate.png
PlotXTel1tXT88Probmate.png
Attachment 2: PlotTel1strxT101calimOk.png
PlotTel1strxT101calimOk.png
Attachment 3: PlotXTel1to4XTProbmate.png
PlotXTel1to4XTProbmate.png
Attachment 4: PlotXTel1to4XTcalimero.png
PlotXTel1to4XTcalimero.png
Attachment 5: PlotXTel1to4XTcalimero.png
PlotXTel1to4XTcalimero.png
Fixede744 Tue May 22 12:10:27 2018 iulian Fairouz ValerieMUST2SoftwareN/ARun #355 Calimero T1-T4 strips Y
Started run #353
Calimero T1-T4 strips Y
Time Calibrator 640 ns ; period 20 ns
Fixede744 Tue May 22 13:40:03 2018 Fairouz ValerieMUST2SoftwareN/ARun #356 Calimero T1-T4 strips Y
Run #356
Time Calibrator Calimero stripYT T1to T4 640ns period 20ns
Pinnede744 Tue May 22 18:33:32 2018 Nicolas, AdrienOTHERSoftware How to run Online and Convert raw data files
1. How to run Basic_online or Online code
  • From any computer (logged as e748 user), type 'online'. This logs you to the lpcgrit server and the online directory
  • From the command line, run 'start_online' to start the Online code
    From the command line, run 'start_basic_online' to start the Basic_online code

2. How to convert raw data files
  • From any computer (logged as e748 user), type 'conversion'. This logs you to the lpcgrit server and the conversion directory

Now, two options are possible (first one is preferred)
  • From the command line, run './run_convert.sh run_number'
    This converts the raw data files which have not been converted yet since run_number
  • From the command line, run './Convert run/run_file_to_convert rootdir/converted_run_name.root
    This converts runs one by one
Fixede744 Tue May 22 19:36:50 2018 Fairouz, ValérieMUST2SoftwareN/ARun #359 Calimero T1-T4 strips X
Run #359
amplitude of the gene is now set to 10 MeV
Time Calibrator Calimero stripsX T1to T4 640ns period 20ns
Attachment 1: CalimeroRunXTampli10MeV.png
CalimeroRunXTampli10MeV.png
Attachment 2: PlotStripsXTcalimero.png
PlotStripsXTcalimero.png
Attachment 3: PlotStripsT1XT67calim1.png
PlotStripsT1XT67calim1.png
Attachment 4: PlotStripsT2XT27calim1.png
PlotStripsT2XT27calim1.png
Attachment 5: PlotStripsT4XT28calim.png
PlotStripsT4XT28calim.png
Attachment 6: PlotStripsT4XT44calim.png
PlotStripsT4XT44calim.png
Attachment 7: PlotEXPulserProbT4.png
PlotEXPulserProbT4.png
Attachment 8: PlotStripsT1toT4XT_run359.png
PlotStripsT1toT4XT_run359.png
Pendinge744 Tue May 22 19:40:26 2018 FrancoisBEAMGeneral Planning of the experiment
Attachment 1: Chekclist_E744_4.pdf
Chekclist_E744_4.pdf Chekclist_E744_4.pdf Chekclist_E744_4.pdf Chekclist_E744_4.pdf Chekclist_E744_4.pdf Chekclist_E744_4.pdf Chekclist_E744_4.pdf Chekclist_E744_4.pdf
Fixede744 Tue May 22 19:40:48 2018 Valérie MUST2GeneralN/Asnapshots for steps in Calimero calibration
Attachment 1: Calimero-step1.png
Calimero-step1.png
Attachment 2: Calimero-step2.png
Calimero-step2.png
Attachment 3: Calimero-step3.png
Calimero-step3.png
Attachment 4: Calimero-step4.png
Calimero-step4.png
Attachment 5: Calimero-step5.png
Calimero-step5.png
Attachment 6: Calimero-step6.png
Calimero-step6.png
Attachment 7: Calimero-step7prog.png
Calimero-step7prog.png
Attachment 8: Calimero-step8proginit.png
Calimero-step8proginit.png
Attachment 9: Calimero-step9startRCC.png
Calimero-step9startRCC.png
Attachment 10: Calimero-step10startcalim.png
Calimero-step10startcalim.png
Attachment 11: CalimeroRunXTampli10MeV.png
CalimeroRunXTampli10MeV.png
Fixede744 Tue May 22 20:06:15 2018 Fairouz, Valerie, edited by Iulian MegumiMUST2SoftwareN/ARun #360 Calimero T1-T4 strips Y
Started run #360
calimero stripsYT T1 to T4 640 ns; period 20 ns
amplitude pulser 10 MeV
There was a problem on T2 as the channel 2 on GMT MASTER was set on TTL.
Attachment 1: Calimero_GMTproblem.png
Calimero_GMTproblem.png
Fixede744 Tue May 22 21:43:31 2018 iulian & megumiMUST2SoftwareN/Arun 361
run 361
start 20h38
stop 21h41
Attachment 1: T1T4_Xstrips_run361.png
T1T4_Xstrips_run361.png
Fixede744 Tue May 22 21:57:51 2018 iulian & megumiMUST2SoftwareN/ARun #362 Calimero T1-T4 strips X again with solution
Changed the Thresholds on T4. No longer double peaks...
I guess there is some noise on the T4 and he triggers on the noise from time to time => double peaks
Also T1-T3 have have strip 16 near pidestal who is counting a lot (red)
Attachment 1: Thresolds_T4_run362.png
Thresolds_T4_run362.png
Attachment 2: T1T4_Xstrips_run362.png
T1T4_Xstrips_run362.png
Fixede744 Tue May 22 22:33:09 2018 e744MUST2SoftwareN/ARun #363 Calimero T1-T4 strips X again with threshold at 50% (same as 40%)
Run #363
NB: Thresholds are the ones on the pulser amplitude to inject the signal (Calimero Pulser interface on Geco). see snapshots on the Calimero summary.
Calimero with 50% thresholds on T4. Same spectra as with the thresholds @40%. I think T4 is triggering on cross-talk, so when the thresholds it's high it's ok.
Attachment 1: T1T4_Xstrips_run363.png
T1T4_Xstrips_run363.png
Fixede744 Tue May 22 22:50:47 2018 e744MUST2SoftwareN/ARun #365 Calimero strips Y T1-T4 100% Threshold
Run #365
Calimero strips Y T1-T4
100% threshold on T4
Something is wrong with the masking?!
Attachment 1: T1T4_Ystrips_run364.png
T1T4_Ystrips_run364.png
Pinnede744 Tue May 22 23:42:02 2018 iulian & megumiEXL-PPTSoftwareN/ARun #366 NARVAL FATAL ERROR
RUN #366
EXL PPT triggers
Falat error from NARAVL


after the error, there is also following message,

____________

Level : WARN
Date : 23/05/2018 00:11:04
Logger : log from NARVAL.storer
Remote Info : localhost:41058
- - - - - - - - - -
Message :
Basic_Storer.Update_Files_Status : File name /data/e748X/e744/acquisition/run/run_0368.dat.22-05-18_23h46m25s already used.

____________

we change the run number to 400, and restart taking data

RUN #400
EXL PPT trigger
for chacking coincidence
Attachment 1: error_narval_run366.png
error_narval_run366.png
Fixede744 Wed May 23 00:30:34 2018 e744EXL-PPTGeneralN/ARUN #402, EXL PPT trigger
RUN #402
start exl ppt run for checking coincidence
exl ch 17 put in to adc2 ch 32
Fixede744 Wed May 23 10:52:28 2018 ValérieEXL-PPTGeneralN/ARUN #405, EXL PPT trigger
RUN #405
start exl ppt run for checking coincidence
Attachment 1: GMTtriggerRun405.png
GMTtriggerRun405.png
Attachment 2: ScalersRun405.png
ScalersRun405.png
Attachment 3: EXL_E1to16duringRun405.png
EXL_E1to16duringRun405.png
Attachment 4: EXL_T1to16duringRun405.png
EXL_T1to16duringRun405.png