MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUST2, Page 15 of 48
Not logged in
Find
|
Login
Full
| Summary |
Threaded
954 Entries
Goto page
Previous
1
,
2
,
3
...
14
, 15,
16
...
46
,
47
,
48
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
e748
Thu Jul 6 01:34:42 2017
e748
RUN
General
CD2
Run 331 (file change)
1:25 file change -> run_0331.dat.05-07-17_18h45m44s.2
18O beam: 6.6 uAe
CATS1: 40000 cps
Fixed
e748
Thu Jul 6 03:35:32 2017
e748
RUN
General
CD2
Run 331 (file change)
3:30 file change -> run_0331.dat.05-07-17_18h45m44s.3
18O: 7.2 uAe
CATS1: 40000 cps
Fixed
e748
Thu Jul 6 05:48:26 2017
e748
MUST2
General
CD2
SiLi 1/T5 trip
Restart SiLi 1/T5 that reached 26 uA and tripped
a few minutes ago.
Current = 21 uA when biased up again, and
Fixed
e748
Thu Jul 6 06:23:18 2017
e748
RUN
General
CD2
Run 331 (file change)
6:19 file change -> run_0331.dat.05-07-17_18h45m44s.4
18O 7.1 uAe
CATS1 : 36000 cps
Fixed
e748
Thu Jul 6 07:17:05 2017
e748
MUST2
General
CD2
SiLi 1/T5 trip
SiLi 1/T5 tripped at 7:16.
We turn it on again immediately -> 23 uA
Fixed
e748
Thu Jul 6 07:23:22 2017
e748
MUST2
Software
CD2
MUST2 : VMECOM : TCP error - TCP/IP : time-out
"MUST2 : VMECOM : TCP error - TCP/IP : time-out"
at 7:19.
RRC shows MUST2 "OFFLINE"
Fixed
e748
Thu Jul 6 07:58:09 2017
e748
MUST2
General
CD2
SiLi 1/T5 triped
SiLi 1/T5 triped at 7:30. We leave it off
while trying to restart the run control.
We turn it on again at 8:03.
Fixed
e748
Thu Jul 6 13:33:23 2017
e748
RUN
General
CD2
Stop of Run 340 due to beam problems
The run 340 was stopped at 13h32. Before the
stop fo the run the beam was unstable and
stopped by machine team.
Fixed
e748
Fri Jul 7 00:25:16 2017
e748
MUST2
Software
CD2
Calibration for CsI
Rough energy calibration for CsI was performed
(only for MM1 and MM4).
Fixed
e748
Fri Jul 7 08:17:38 2017
e748
RUN
General
CD2
Run 347
Stop run 346 and start run 347 after rewriting
parameters onto CHIO digitizer.
Digitized CHIO signals back in Vigru.
Fixed
e748
Fri Jul 7 08:56:43 2017
e748
MUST2
General
CD2
SiLi 1/T5 current
SiLi 1/T5: 380V, 24.9 uA (current limit set
at 26 uA)
Apparently, it hasn't triped since July 6,
Fixed
e748
Fri Jul 7 10:46:21 2017
e748
MUST2
General
CD2
SiLi 1/T5 current
HV = 380 V
I = 25.1 uA
Fixed
e748
Fri Jul 7 10:56:12 2017
e748
RUN
General
CD2
Run 347 (file change)
10:50 data file change -> run_0347.dat.07-07-17_08h15m06s.1
18O: 7.5 uAe
CATS1 42 kcps
Fixed
e748
Fri Jul 7 12:00:29 2017
e748
RUN
General
CD2
Stop run 347 - Short machine problem
Short beam interruption due to a machine problem.
We stop run 347.
Fixed
e748
Fri Jul 7 12:02:02 2017
e748
RUN
General
CD2
Run 348
Restart after short machine problem.
Same conditions as previous run.
Fixed
e748
Fri Jul 7 15:15:42 2017
e748
BEAM
General
CD2
Runs 349 to 364 - 10Be LISE tuning
Slits F31 = +/- 20 mm
Momentum acceptance = 2.5 % total
Fixed
e748
Fri Jul 7 15:20:45 2017
e748
BEAM
General
CD2
Run 365 - 10Be LISE tuning
Slits F31 = +/- 4 mm
Momentum acceptance = 0.5 % total
2 uAe -> 80000 cps on CATS
Fixed
e748
Fri Jul 7 15:55:29 2017
e748
BEAM
General
CD2
Run 366 - 10Be tuning - Centering on TARGET
FH31 slits = +/- 4 mm
DAC2 = -3 A
Fixed
e748
Fri Jul 7 16:01:22 2017
e748
RUN
General
CD2
Run 367
FH31 slits (momentum slits) = +/- 4 mm
DAC2 = -3 A
Triggers = MUST2, CATS1div, CATS2div
Fixed
e748
Fri Jul 7 16:32:24 2017
e748
RUN
General
CD2
summary of runs 363-367
/data/e748X/e748/acquisition/run
r--r--r-- 1 e748 Exxx 19M 7 juil. 15:01
Goto page
Previous
1
,
2
,
3
...
14
, 15,
16
...
46
,
47
,
48
Next
ELOG Home Page