Fixed, e744s, Thu Apr 11 18:36:34 2019, Beyhan, BEAM, General, , before optimization : beam reconstructed profil with VAMOS and assoicated settings IMG_1583.jpgIMG_1582.jpg
target : hole
cats2 out
about 4000 pps triggering VAMOS
Fixed, e768s, Wed Jul 17 09:07:19 2019, mugast, BEAM, General, , beam settings 20190717_061639.jpg
values as it is now
Fixed, , Wed Feb 26 15:04:29 2020, mugast, RUN, General, , beam retuning 
Beam is retuned from PCP to improve its quality
Fixed, e744s, Sat Apr 13 13:58:08 2019, Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH, BEAM, Hardware, CH2, beam rate (read from CATS) as a function of time rate_vs_time.pdf
 
Fixed, e793s, Sat Mar 13 11:16:38 2021, Lynda, Laetitia, Chloe, BEAM, General, , beam lost and back 
we loose the beam around 11:12, it should be back in few minutes according to pcp.

11:18: the beam is back (3.5E5 pps)
Pending, e793s, Thu Mar 11 09:02:20 2021, mugast, BEAM, Hardware, CD2, beam interruption 
power supply trip on the accelerator beam is off for about 30min
Fixed, e768s, Tue Jul 16 12:10:05 2019, Francois, BEAM, General, LiF, beam intensity, normalisation, elastic scattering 7Li scattering.jpgscattering2.jpg
In 2005, the 15O1+ beam was measured at 6x10^7 pps after the CIME cyclotron, contaminated with ~nAe of 15N1+.
After stripper (aluminium stripper at LISE) the purity was 97 % of 15O8+ with 3 % of 15N8+.
Fixed, e768s, Sun Jul 21 17:02:25 2019, Marlène, BEAM, General, , beam intensity in the afternoon run_119_scaler3.png
 
Fixed, e768s, Sun Jul 21 22:40:23 2019, Kseniia & Nicolas, BEAM, General, N/A, beam check run121 IMG_20190721_223618_beamcheck.jpgscalers_1.png
best intensity ever: 2.2e7 pps
Fixed, e793s, Sat Mar 13 13:46:42 2021, Chloe F., OFFLINE, General, CD2, analysis gg gg_e793s_gat.pnggg_e793s_gat_2.png
> > Up to now data (run 46-51-52-53-55-56-60-61-62)
Decays seen from level scheme:
3- (451,280)keV
Fixed, e786s, Wed Jun 26 13:48:35 2019, mugast, OFFLINE, General, Cryo-3He, analysis Ekine_Ex_run56_58.png
 
Fixed, e744s, Mon Apr 15 21:58:15 2019, iulian Beyhan, VAMOS, Hardware, CH2, Xf efficiency evolution  Xf_efficency_change_122_vs_130_vs_131.pdf
Xf efficiency (normalized to CATS intensity) is directly linked with the beam intensity. The image below show a comparison between normalised Xf spectra
on 3 different runs taken with different beam intensities:
Run 122 2019-04-13 06:31:00 4e+4
    Fixed, com2019, Sat Apr 6 10:09:53 2019, Adrien Matta, OFFLINE, General, CD2, We see d,4He 
[quote="Adrien Matta"]We see more (d.3he) than dt

there seems to be another reaction going up to 40deg Lab[/quote]
Fixed, com2019, Sat Apr 6 08:38:51 2019, Adrien Matta, OFFLINE, General, CD2, We see d,3he more than d,t at forward angle Kine256_0-256_3.pdf
We see more (d.3he) than dt

there seems to be another reaction going up to 40deg Lab
Fixed, e768s, Mon Jul 22 06:32:40 2019, Faïrouz & Sylvain, RUN, General, LiF, We put the Faraday cup because AGATA can not cope with the very high counting rate (>110kHz) 
We will call Emmanuel & Bertrand. 
We stopped the run 122, waiting for Bertrand to come and work on the beam size and focalization. 
Pinned, e768s, Sat Jul 27 06:47:16 2019, Sylvain & Andrea, OTHER, General, LiF, Water tray of MUGAST air conditioner cooling system is almost full 
During a room inspection it was notice that the water tray used as an output of the fan system which is cooling MUGAST electronic crates is almost full
of water. The floor is dry but the we suspect a leakage from the air conditioner. To avoid to flood the floor we took some of the water and put in in the
water tray of the fan system located in front of VAMOS.
Fixed, e768s, Tue Jul 23 19:21:50 2019, Nicolas, OTHER, Social, N/A, Waiting end of canicule (and beam!) IMG_20190723_173257.jpg
 
Fixed, e744s, Sat Apr 13 23:02:27 2019, Valerian, Freddy and Iulian, OFFLINE, General, CH2, Very preliminary results for two protons TwoProtons_run122_0_1.png
Join are very preliminary spectra for the two protons events gated on 13N in VAMOS with a multiplicity 2 event in MUST2.
Fixed, e744s, Sat Apr 13 23:19:57 2019, Valerian, Freddy, Iulian and Fairouz, OFFLINE, Software, CH2, Very preliminary results for two protons TwoProtonsMult1_run122_0_1.png
Join are very preliminary spectra for the two protons events gated on 13N in VAMOS with a multiplicity 1 event in MUST2. This condition adds a lot of noise.
Fixed, e793s, Sat Mar 13 02:31:33 2021, Faïrouz, Juan Lois, VAMOS, Hardware, CD2, Vamos tripped @ 2h32 & fixed 
 