MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 96 of 132
Not logged in
Find
|
Login
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
95
, 96,
97
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
e768s
Tue Jul 16 18:21:05 2019
OttoRun
RUN
General
Empty
Run55
*************************
[SIZE=3][B]Run : 55[/B][/SIZE]
*************************
Fixed
e768s
Tue Jul 16 18:49:42 2019
OttoRun
RUN
General
Empty
Run56
*************************
[SIZE=3][B]Run : 56[/B][/SIZE]
*************************
Fixed
Tue Jul 16 18:51:06 2019
mugast
VAMOS
General
LiF
15N beam optimisation
Fixed
e768s
Tue Jul 16 18:58:01 2019
OttoRun
RUN
General
Empty
Run57
*************************
[SIZE=3][B]Run : 57[/B][/SIZE]
*************************
Fixed
e768s
Tue Jul 16 19:04:39 2019
OttoRun
RUN
General
Empty
Run58
*************************
[SIZE=3][B]Run : 58[/B][/SIZE]
*************************
Fixed
e768s
Tue Jul 16 19:21:19 2019
mugast
OTHER
General
Qpole values
Brho = 0.640 Tm
RMN = 3247,742 Gaus (215.630 A)
Fixed
e768s
Tue Jul 16 20:37:10 2019
OttoRun
RUN
General
LiF
Run59
*************************
[SIZE=3][B]Run : 59[/B][/SIZE]
*************************
Fixed
e768s
Tue Jul 16 20:43:05 2019
OttoRun
RUN
General
LiF
Run60
*************************
[SIZE=3][B]Run : 60[/B][/SIZE]
*************************
Fixed
e768s
Tue Jul 16 21:30:19 2019
Chloe Fougeres
OTHER
General
LiF
PACE4 fusion-evaporation
Simulated yields with beams 15N and 15O (4.7
MeV/u) on target LiF.
Fixed
e768s
Tue Jul 16 22:25:51 2019
mugast
OTHER
General
Oxygen 15 decay scheme
beta+ decay to the ground state of 15N
gammas @ 511 keV
Fixed
e768s
Wed Jul 17 01:08:03 2019
mugast
VAMOS
General
LiF
new beam settings
The last values Q32=21.0, Q31=22.8
With these new optimzed values, we have:
Fixed
e768s
Wed Jul 17 01:42:46 2019
mugast
VAMOS
General
LiF
Beam intensity versus Trigger Vamos
Masque mobile at +7 mm
Beam: 10^5 pps, Fag:10, Trigger VAMOS:10
Fixed
e768s
Wed Jul 17 01:51:10 2019
mugast
BEAM
General
Faisceau perdu
Un Q-pole dans L3 est tombé. L'opérateur a
du mal à le redémarrer. Bertrand et un technicien
ont essayé de réparer mais sans succès.
Fixed
e768s
Wed Jul 17 03:56:59 2019
OttoRun
RUN
General
LiF
Run61
*************************
[SIZE=3][B]Run : 61[/B][/SIZE]
*************************
Fixed
e768s
Wed Jul 17 05:32:57 2019
OttoRun
RUN
General
LiF
Run63
*************************
[SIZE=3][B]Run : 63[/B][/SIZE]
*************************
Fixed
e768s
Wed Jul 17 05:47:48 2019
OttoRun
RUN
General
LiF
Run64
*************************
[SIZE=3][B]Run : 64[/B][/SIZE]
*************************
Fixed
e768s
Wed Jul 17 06:29:27 2019
OttoRun
RUN
General
LiF
Run67
*************************
[SIZE=3][B]Run : 67[/B][/SIZE]
*************************
Fixed
e768s
Wed Jul 17 07:42:53 2019
OttoRun
RUN
General
LiF
Run69
*************************
[SIZE=3][B]Run : 69[/B][/SIZE]
*************************
Fixed
e768s
Wed Jul 17 07:53:09 2019
OttoRun
RUN
General
LiF
Run70
*************************
[SIZE=3][B]Run : 70[/B][/SIZE]
*************************
Fixed
e768s
Wed Jul 17 08:00:34 2019
Francois
BEAM
General
LiF
summary of the night
0h-2H : beam tuning
2H Qpole down
4H Qpole problem solved but AGATA GGP problem
Goto page
Previous
1
,
2
,
3
...
95
, 96,
97
...
130
,
131
,
132
Next
ELOG Home Page