Status ExpNbr Datedown Author Type Category Target-Source Subject
Pinnede793s Fri Mar 12 15:48:35 2021 AdrienRUNGeneralN/AVamos D and Q value and MW HV
Fixede793s Fri Mar 12 15:19:35 2021 OttoRunRUNGeneralCD2Run60
*************************
Run : 60
*************************

Start at 2021-03-12 15:19:14.732769

Test run. ACQ DT

ATC6 pos 0 is back
14C is removed
starting again after beam line reparation of power supply

Beam: 3.5e5 pps
target: CD2 0.5mg
Trigger are MUGAST/MM/CATS%

Stop at 2021-03-12 16:53:37.438208
Stop comment: stop run after tuning of the beam
Fixede793s Fri Mar 12 13:40:59 2021 OttoRunRUNGeneralCD2Run59
*************************
Run : 59
*************************

Start at 2021-03-12 13:40:31.431982

Test run. ACQ DT

(ATC6 crystal stopped)
starting again after beam line reparation of power supply

Beam: 3.5e5 pps
target: CD2 0.5mg
Trigger are MUGAST/MM/CATS%

Stop at 2021-03-12 13:42:17.319503
Stop comment: stopping daq because agata daq did not start
Ongoinge793s Fri Mar 12 12:58:10 2021 Emmanuel COFFLINEGeneral Gamma Gamma Analysis
Attachment 1: 48K.pdf
48K.pdf
Attachment 2: e793s_1.png
e793s_1.png
Attachment 3: e793s_142Gated.png
e793s_142Gated.png
Attachment 4: e793s_280Gated.png
e793s_280Gated.png
Attachment 5: e793s_451Gated.png
e793s_451Gated.png
Attachment 6: e793s_1842Gated.png
e793s_1842Gated.png
Attachment 7: e793s_3523Gated.png
e793s_3523Gated.png
Fixede793s Fri Mar 12 10:52:46 2021 AdrienVAMOSHardwareN/AQ pole trip in vamos
Q-Pole tripped this night around 4am at the same time as the dipole but was switch on again only at 9am.
Fixede793s Fri Mar 12 10:32:41 2021 OttoRunRUNGeneralCD2Run57
*************************
Run : 57
*************************

Start at 2021-03-12 10:32:22.121271

Test run. ACQ DT

(ATC6 crystal stopped)
New beam tune with better centering from Bertrand

Beam: 3.5e5 pps
target: CD2 0.5mg
Trigger are MUGAST/MM/CATS%

Stop at 2021-03-12 11:12:37.613523
Stop comment: type your message here
Fixede793s Fri Mar 12 10:07:29 2021 mugastMECHHardware Leak

https://www.hometree.co.uk/energy-advice/home-cover/common-water-leaks-and-how-to-fix-them.html
Fixede793s Fri Mar 12 09:57:30 2021 AdrienOTHERSocialN/ALost phone in agata counting room
Someone lost his/her phone in the agata counting room. Pictures attached.
Attachment 1: 161C9D73-3ED8-49DE-A1EF-4ED9AA11C912.jpeg
161C9D73-3ED8-49DE-A1EF-4ED9AA11C912.jpeg
Fixede793s Fri Mar 12 09:55:30 2021 FrancoGRITGeneralCD2MM5
The first plot attached has been done by artificially removing 7 deg in theta lab, just to see if the the kinematic lines of 47K(d,d) and 47K(p,p) can be reproduced. Of course the energy losses are not optimized in this case but anyway the agreement seems nice.
In the second plot I moved MM5 forward (in z) by 17.5 mm, without any re-orientation in x and y. We should compare this position with the one measured by the surveyors.
It looks like we have plenty of protons in the target but actually the Rutherford cross section at 80 deg for (p,p) is 4 times higher than the (d,d) one. From a quick estimation the ratio 2H:1H in the target should be around 3:1 (to be checked!).
Attachment 1: square_shifted_theta.png
square_shifted_theta.png
Attachment 2: square_shifted_Z.png
square_shifted_Z.png
Fixede793s Fri Mar 12 09:52:01 2021 mugast (Sarah, Louis)OFFLINEGeneralCD2Offline analysis run up to 56 8am
1) A high energy gamma has been identified at 3505 keV by gating on 3-5 MeV range in excitation energy. This transition is unknown so far

2) preliminary angular distribution has been extracted for the p states(<1MeV) and the f states (3-5MeV) corrected from geometrical efficiency. Angular distribution with gate on the 3.5 MeV gamma was also extracted. Too few statistics to tell anything. Need at least 4 time more statistics to have a proper angular distribution.
Attachment 1: AngDisrtib.png
AngDisrtib.png
Attachment 2: 3MeV_gamma.png
3MeV_gamma.png
Attachment 3: AWBA.png
AWBA.png
Fixede793s Fri Mar 12 08:58:09 2021 AdrienBEAMHardwareCD2Beam is stopped 8h55
Beam stopped to fix a leak on the accelerator. Intervention up to 4hours, maybe less.
Fixede793s Fri Mar 12 06:23:44 2021 Taras, Nishu, Chloe, CharlieRUNGeneralCD2run56 screenshots at 06h15
Screenshots attached
Attachment 1: run56_Scalers_06h14.png
run56_Scalers_06h14.png
Attachment 2: run56_MG-IMPACT_MATRIX_06h15.png
run56_MG-IMPACT_MATRIX_06h15.png
Attachment 3: run56_MM_ToF_06h15.png
run56_MM_ToF_06h15.png
Attachment 4: run56_MM_DeE_06h15.png
run56_MM_DeE_06h15.png
Attachment 5: run56_MG_ToF_06h15.png
run56_MG_ToF_06h15.png
Attachment 6: run56_TAC_06h15.png
run56_TAC_06h15.png
Attachment 7: run56_FSC_06h12.png
run56_FSC_06h12.png
Attachment 8: run56_VAMOS_MW_06h20.png
run56_VAMOS_MW_06h20.png
Attachment 9: run56_MM_IMPACT_MATRIX_06h20.png
run56_MM_IMPACT_MATRIX_06h20.png
Attachment 10: run56_ELab_ThetaLab_06h10.png
run56_ELab_ThetaLab_06h10.png
Fixede793s Fri Mar 12 04:19:51 2021 Taras, Nishu, Chloe, CharlieRUNGeneralCD2run56 screenshots at 04h18
Images attached.
Attachment 1: run56_Scalers_04h14.png
run56_Scalers_04h14.png
Attachment 2: run56_MG-IMPACT_MATRIX_04h15.png
run56_MG-IMPACT_MATRIX_04h15.png
Attachment 3: run56_MM_ToF_04h15.png
run56_MM_ToF_04h15.png
Attachment 4: run56_MM_DeE_04h15.png
run56_MM_DeE_04h15.png
Attachment 5: run56_MG_ToF_04h15.png
run56_MG_ToF_04h15.png
Attachment 6: run56_TAC_04h15.png
run56_TAC_04h15.png
Attachment 7: run56_MM_RawX_04h10.png
run56_MM_RawX_04h10.png
Attachment 8: run56_MM_RawY_04h10.png
run56_MM_RawY_04h10.png
Attachment 9: run56_MM_TX_04h10.png
run56_MM_TX_04h10.png
Attachment 10: run56_MM_TY_04h11.png
run56_MM_TY_04h11.png
Attachment 11: run56_FSC_04h12.png
run56_FSC_04h12.png
Attachment 12: run56_VAMOS_MW_04h20.png
run56_VAMOS_MW_04h20.png
Attachment 13: run56_MM_IMPACT_MATRIX_04h20.png
run56_MM_IMPACT_MATRIX_04h20.png
Attachment 14: run56_ELab_ThetaLab_04h10.png
run56_ELab_ThetaLab_04h10.png
Fixede793s Fri Mar 12 03:57:46 2021 Taras, Nishu, Chloe, CharlieVAMOSGeneralCD2dipole issue fixed
the alimentation on dipole (G1.G.D4.P) was turned off,
the value was resetted(322.6) and works fine now.
cour: 323.5 A
tens. 39.21 V
Attachment 1: run56_dipolefixed.png
run56_dipolefixed.png
Fixede793s Fri Mar 12 03:21:01 2021 Taras, Chloe, NIshu, CharlieVAMOSGeneralCD2VAMOS trip, requires help (FIXED @ 03:55)
We received a call from PCP telling us that VAMOS has tripped. Currents on all focal planes are 0. We tried stopping and restarting the FP_CATS0 - FP_CATS5, but this does not resolve the issue.

A picture of the VAMOS control screen is attached. Diego has been contacted.

EDIT:::
Diego has informed us that the focal plane current is not the issue. The problem instead is with G1.G.D4.P (dipole?) in VAMOS. This has tripped off (see second attached image). He has advised us to call Bertrand to fix this.

EDIT2:::
Bertrand called an operator, and the VAMOS count rate is now back up to normal. The whole process from crash to fix took ~half an hour
Attachment 1: PXL_20210312_020550869.jpg
PXL_20210312_020550869.jpg
Attachment 2: PXL_20210312_024401845.jpg
PXL_20210312_024401845.jpg
Fixede793s Fri Mar 12 02:01:52 2021 Taras, Nishu, Chloe, CharlieRUNGeneralCD2run56 screenshots at 02h10
screenshots of run 56 attached below
Attachment 1: run-56_screenshot.png
run-56_screenshot.png
Attachment 2: vamos_screenshot.png
vamos_screenshot.png
Attachment 3: run56_MG-IMPACT_MATRIX_02h10.png
run56_MG-IMPACT_MATRIX_02h10.png
Attachment 4: run56_MM_ToF_02h10.png
run56_MM_ToF_02h10.png
Attachment 5: run56_MM_DeE_02h10.png
run56_MM_DeE_02h10.png
Attachment 6: run56_MG_ToF_02h10.png
run56_MG_ToF_02h10.png
Attachment 7: run56_TAC_02h10.png
run56_TAC_02h10.png
Attachment 8: run56_MM_TX_02h10.png
run56_MM_TX_02h10.png
Attachment 9: run56_MM_TY_02h11.png
run56_MM_TY_02h11.png
Attachment 10: run56_ELab_ThetaLab_02h10.png
run56_ELab_ThetaLab_02h10.png
Fixede793s Thu Mar 11 23:38:02 2021 Faïrouz, FrancoRUNGeneralCD2No beam at 23h35 for a duration of ~1à mn
The beam operators took the beam at 23h35 for 10 mn.
Attachment 1: run56_Scalers_23h44.png
run56_Scalers_23h44.png
Fixede793s Thu Mar 11 23:30:27 2021 Faïrouz, FrancoRUNGeneralCD2run56 screenshots at 23h20
Attachment 1: run56_VAMOS_MW_23h20.png
run56_VAMOS_MW_23h20.png
Attachment 2: run56_MM_IMPACT_MATRIX_23h20.png
run56_MM_IMPACT_MATRIX_23h20.png
Attachment 3: run56_MG-IMPACT_MATRIX_23h20.png
run56_MG-IMPACT_MATRIX_23h20.png
Attachment 4: run56_MM_ToF_23h20.png
run56_MM_ToF_23h20.png
Attachment 5: run56_MM_DeE_23h20.png
run56_MM_DeE_23h20.png
Attachment 6: run56_MG_ToF_23h24.png
run56_MG_ToF_23h24.png
Attachment 7: run56_TAC_23h20.png
run56_TAC_23h20.png
Attachment 8: run56_Scaler_23h20.png
run56_Scaler_23h20.png
Fixede793s Thu Mar 11 21:29:43 2021 FrancoRUNGeneralCD2Alignment in time of the VAMOS sections
The aligned time is saved in a variable called MWT in the output tree
Attachment 1: VAMOS_T_alignment.png
VAMOS_T_alignment.png
Fixede793s Thu Mar 11 21:14:26 2021 Fairouz & FrancoOFFLINEGeneralCD2Plots run 51-56
Top left: kinematic plot with the main levels observed. The orange lines are (d,p), (d,t), (d,d) and (12C,12C) reactions by 47Ti. The yellow line is 47K(p,p), the green line 47K(d,d).
Top right: in black Ex spectrum with gate on VAMOS, in red with also the gate on a gamma and scaled by a factor 3 for better comparison.
Bottom left: Egamma vs Ex with gate on VAMOS.
Bottom right: Egamma with gate on VAMOS.
Attachment 1: plots_51-56.png
plots_51-56.png
Attachment 2: Ex_thetalab_51-56.png
Ex_thetalab_51-56.png

ELOG Home Page