Fixed, e768s, Sat Jul 20 19:12:58 2019, Faïrouz & Sylvain, RUN, General, LiF, Run 118 screenshots @ 19h14 20x
|
|
Fixed, e768s, Thu Jul 18 19:40:11 2019, iulian, OFFLINE, General, LiF, Ex in 19F from run 72   
|
Excitation energy spectra in 19F obtained by conditioning Z==9 and (A/Q*8-19)<0.3 in Vamos for
MG5
MG11
|
Fixed, e768s, Thu Jul 18 22:50:58 2019, iulian, Jenn, Franco, OFFLINE, General, LiF, Ex in 19F from run 72
|
Gamma energy vs excitation energy in 19F with all backward detectors for run 0072_0 |
Fixed, e768s, Sat Jul 20 19:23:37 2019, Christiqn, OFFLINE, General, LiF, Ex in 19F from run 72
|
[B]Data: Total integral for peak region around 4 MeV in 19F during run 72:
[/B]
|
Fixed, e768s, Sat Jul 20 19:24:31 2019, Faïrouz & Sylvain, RUN, General, LiF, Beam intensity is decreasing.
|
The beam intensity decreased by half since 19h00 (600 in Vamos-or)due to the primary beam.
The operators are working on it since.
The intensity of 10^7 pps came back at 8 pm.
|
Fixed, e768s, Sat Jul 20 21:10:57 2019, Faïrouz & Sylvain, RUN, General, LiF, Run 118 stopped because VXI Vamos turned offline because of overheat
|
Run 118 stopped because VXI Vamos turned offline of overheat |
Fixed, e768s, Sat Jul 20 23:18:02 2019, OttoRun, RUN, General, LiF, Run119
|
*************************
[SIZE=3][B]Run : 119[/B][/SIZE]
*************************
|
Fixed, e768s, Sat Jul 20 19:21:56 2019, Marlene, Nicolas, Christian, Fairouz, OFFLINE, General, , Trying to understand AGATA g-ray yields
|
goal: we want to check whether the yields of the 1297.7 keV (from 19Ne 1536, 3/2+, l=1 state) and 1340 keV (from 19Ne 1615, 3/2-, l=2 state) g-ray lines
is compatible with what we expect from x-sec calculations
|
Fixed, e768s, Sat Jul 20 23:32:44 2019, Sylvain Fairouz, OFFLINE, General, , Trying to understand AGATA g-ray yields
|
[quote="Marlene, Nicolas, Christian, Fairouz"]goal: we want to check whether the yields of the 1297.7 keV (from 19Ne 1536, 3/2+, l=1 state) and 1340 keV
(from 19Ne 1615, 3/2-, l=2 state) g-ray lines is compatible with what we expect from x-sec calculations
|
Fixed, e768s, Sat Jul 20 23:43:02 2019, mugast, RUN, General, LiF, Run 119 (Problem with VXI fixed for the moment)
|
Run 119.
Or-Vamos= 1430 ---> I=1.43x10^7 pps |
Fixed, e768s, Sat Jul 20 23:57:34 2019, Diego, OFFLINE, General, , VAMOS acceptance, comparison between 9+ and 10+ states
|
Figures above, simulation of VAMOS acceptance for 10+ and 9+ 19Ne charge states. Ratio between them quite big (0.58)
Figures below, comparison of the states with offline data. Ratio much smaller.
It seems like acceptance doesn't cut the 10+ charge state too much, but 10+ is less produced than 9+. |
Fixed, e768s, Sun Jul 21 01:57:59 2019, Jenn & Franck, ONLINE, General, LiF, Screenshots run 119 21x
|
|
Fixed, TEST, Sun Jul 21 02:42:56 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green] [/COLOR] Slot: [COLOR=blue]8 [/COLOR] (A1821H) Channel:[COLOR=blue]1 [/COLOR] Vmon: [COLOR=blue] 0 V [/COLOR] Imon:
[COLOR=blue]0.001 uA[/COLOR] Status: [COLOR=pink]Off[/COLOR]
|
Fixed, TEST, Sun Jul 21 02:42:56 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green]+10v/mg [/COLOR] Slot: [COLOR=blue]5 [/COLOR] (A1516B) Channel:[COLOR=blue]5 [/COLOR] Vmon: [COLOR=blue] 10 V [/COLOR] Imon:
[COLOR=blue]0.407 A [/COLOR] Status: [COLOR=green]On[/COLOR]
|
Fixed, e768s, Sun Jul 21 10:58:39 2019, Christian, AGATA, General, LiF, 13c resync
|
13c resync at 10.57
lost 5 min agata data |
Fixed, TEST, Sun Jul 21 11:47:28 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green] [/COLOR] Slot: [COLOR=blue]8 [/COLOR] (A1821H) Channel:[COLOR=blue]1 [/COLOR] Vmon: [COLOR=blue] 0 V [/COLOR] Imon:
[COLOR=blue]0.001 uA[/COLOR] Status: [COLOR=pink]Off[/COLOR]
|
Fixed, TEST, Sun Jul 21 11:47:28 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green]+10v/mg [/COLOR] Slot: [COLOR=blue]5 [/COLOR] (A1516B) Channel:[COLOR=blue]5 [/COLOR] Vmon: [COLOR=blue] 10 V [/COLOR] Imon:
[COLOR=blue]0.408 A [/COLOR] Status: [COLOR=green]On[/COLOR]
|
Fixed, e768s, Sun Jul 21 11:49:59 2019, Christiqn qnd Didier, RUN, General, LiF, Run 119 screenshots  
|
|
Fixed, e768s, Sun Jul 21 14:54:28 2019, Marlène, RUN, General, , run 119 scalers 
|
|
Fixed, e768s, Sun Jul 21 16:39:38 2019, Marlène, Antoine, BEAM, General, , IMPORTANT :How to send scalers to PCP
|
Go to PCP
Open a terminal
|
Fixed, e768s, Sun Jul 21 16:42:20 2019, Marlène, OFFLINE, General, , Conversion of data from AGATA :update
|
When VAMOS VXI crashed (run 118) the Action file was recompiled.
As AGATA conversion is not copying the ACTION file for each run, it used the old version by default (from 16th of july).
|
Fixed, , Sun Jul 21 16:51:30 2019, Marlène, Christian, Ksenia, BEAM, General, , trial of tracking of the implantation of 15O
|
Looking at AGATA count rate, we have seen that the highest counting rate for 511 keV line is seen in the inner ring (0*A clusters).
The outer ring detectors (10B for example) counts 10 times less.
|
Fixed, e768s, Sun Jul 21 17:02:25 2019, Marlène, BEAM, General, , beam intensity in the afternoon
|
|
|