MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 7 of 132
Not logged in
Find
|
Login
New entries since:
Thu Jan 1 01:00:00 1970
Full |
Summary
|
Threaded
|
Hide attachments
2636 Entries
Goto page
Previous
1
,
2
,
3
...
6
, 7,
8
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Fixed
e793s
Mon Mar 8 18:15:07 2021
mugast
GRIT
General
N/A
Run 634 - TACs calibration (part 4)
TAC calibration.
AGATA-CATS2 (range 200 ns)
Time calibrator
2.56 us range
10 ns steps
Fixed
e793s
Tue Mar 9 10:22:16 2021
mugast
DAQ
Hardware
N/A
U2M scaler configuration
U2M
1-FAG
2-OR MM-MG
3-OR AGATA
4-TRIG VAMOS
5-CATS CLEAN
6-DT && OR MM-MG
7-100 Hz
8-100 Hz & DT
9-MUVI1
10-MUVI2
11-MUVI3
12-MUVI4
15-CATS2 direct
16- FINGER (unused)
Fixed
e793s
Tue Mar 9 10:47:12 2021
mugast
DAQ
Hardware
N/A
GMT config
GMT
1-MUVI1
2-MUVI2
3-MUVI3
4-
5-CATS2clean % (/10**4 for the moment)
6-VAMOS% (/10 for the moment)
7-MUST2% (/10 for the moment)
8-
9-
10-VAMOS
11-OR AGATA
Fixed
e793s
Wed Mar 10 19:23:37 2021
mugast
OFFLINE
General
CD2
Kinematics and Ex - RUN051
Preliminary analysis results, Backward angles.
MM5 position are incorrect
Attachment 1:
RUN51_ELabThethaLab_Ex.png
Attachment 2:
RUN51_ELabThethaLab_Ex_Egamma.png
Pending
e793s
Thu Mar 11 09:02:20 2021
mugast
BEAM
Hardware
CD2
beam interruption
power supply trip on the accelerator beam is off for about 30min
Fixed
e793s
Thu Mar 11 11:07:05 2021
mugast
OFFLINE
General
CD2
run53 - Egamma vs Ex
Attachment 1:
Egamma_vs_Ex_run53.png
Fixed
e793s
Thu Mar 11 15:48:14 2021
mugast
OFFLINE
General
N/A
Beam energy and Beta
Beam energy entering G1: 7.6922 MeV/u (Beta= 0.1277)
CATS2 thickness: 2.8 um of Mylar in total + about 4 cm of isobutane at 4 mbar
7.62783 / 7.61264 / 7.54789
Beam energy after CATS: 7.54789 MeV/u (Beta= 0.1265)
Beam at mid CD2 target : 7.45118 MeV/u (Beta= 0.1257)
Beam after target: 7.35381 MeV/u (Beta= 0.1249)
Fixed
e793s
Fri Mar 12 10:07:29 2021
mugast
MECH
Hardware
Leak
https://www.hometree.co.uk/energy-advice/home-cover/common-water-leaks-and-how-to-fix-them.html
Fixed
e793s
Fri Mar 12 20:54:30 2021
mugast
RUN
General
CD2
summary of run 61
Attachment 1:
scalers.png
Attachment 2:
vamos.png
Attachment 3:
Screenshot_from_2021-03-12_20-57-53.png
Attachment 4:
Screenshot_from_2021-03-12_20-58-15.png
Attachment 5:
Screenshot_from_2021-03-12_20-58-45.png
Fixed
e793s
Mon Mar 15 02:08:19 2021
mugast
BEAM
General
CD2
Beam stopped at 2:08
Beam stopped at 2h08. The PCP want to make some measurement on the source to get its statues. Should take about 10 min.
Fixed
e793s
Mon Mar 22 18:15:50 2021
mugast
RUN
General
N/A
TACS calibration - run 662
TACS:
FAG-CATS2 (range 500 ns)
VAMOS-AGATA (range 500 ns)
CATS2-CATS2 (not in modular label) (range 500 ns)
AGATA-CATS2 (range 200 ns)
Time calibrator settings:
640 ns range
20 ns steps
Fixed
e793s
Mon Mar 22 19:04:55 2021
mugast
RUN
General
N/A
TACS calibration - run 653
TACS:
MUGAST-AGATA (range 2 us)
MUGAST-CATS2 (range 1 us)
MUGAST-CATS2b (range 2 us)
MUGAST-VAMOS (range 2 us)
VAMOS-CATS2 (range 2 us)
Time calibrator settings:
2.56 us range
80 ns steps
Fixed
Thu Mar 28 18:29:04 2019
marlene valerian
GRIT
General
3-alpha
RUN 147 3alpha source overnight all detectors -4deg
RUN 147 start@ 18:30
3 alpha source over night
cooling at -4 deg on all detectors
warning !!! FIFO for BLK signal has been put in 4x4 instead of 2x8, BLK is only coming from the 3 VXI of MUGAST
Mon Apr 15 20:42:47 2019
marlene iulian beyhan valérian
Fixed
com2019
Tue Apr 2 16:24:06 2019
marlene freddy
OTHER
General
N/A
Commissioning proposal
Attachment 1:
MUGAST_commissioning-3.pdf
Fixed
Tue Mar 19 19:35:53 2019
marlene
GRIT
General
RUN 98 3alpha source all detectors
RUN 98
3 alpha source
all detectors (trap,square, MUST2,annular)
Temp=15deg
Acquisition mugast
Fixed
e744s
Tue Apr 16 00:01:43 2019
louis, Guiseppe
ONLINE
General
CH2
Online snapshot from run 132
Online snapshot from run 132
Attachment 1:
run131_Mugast_28.png
Attachment 2:
run131_Mugast_27.png
Attachment 3:
run131_Mugast_26.png
Attachment 4:
run131_Mugast_25.png
Attachment 5:
run131_Mugast_24.png
Attachment 6:
run131_Mugast_23.png
Attachment 7:
run131_Mugast_22.png
Attachment 8:
run131_Mugast_21.png
Attachment 9:
run131_Mugast_20.png
Attachment 10:
run131_Mugast_19.png
Attachment 11:
run131_Mugast_18.png
Attachment 12:
run131_Mugast_17.png
Attachment 13:
run131_Mugast_16.png
Attachment 14:
run131_Mugast_15.png
Attachment 15:
run131_Mugast_14.png
Attachment 16:
run131_Mugast_13.png
Attachment 17:
run131_Mugast_12.png
Attachment 18:
run131_Mugast_11.png
Attachment 19:
run131_Mugast_10.png
Attachment 20:
run131_Mugast_9.png
Fixed
e744s
Tue Apr 16 01:55:29 2019
louis, Guiseppe
ONLINE
General
CH2
Log & Scalers -- Run 132 at 2:00
Some of the spectra for VAMOS (in particular DC_EWIRE and IC_SUMMARY) disappeared
Attachment 1:
run132_scaler.png
Attachment 2:
run132_VAMOS_1_2.png
Attachment 3:
run132_VAMOS_1_3.png
Attachment 4:
run132_VAMOS_1_4.png
Attachment 5:
run132_VAMOS_1_5.png
Attachment 6:
run132_VAMOS_1_6.png
Attachment 7:
run132_VAMOS_1_7.png
Attachment 8:
run132_VAMOS_1_9.png
Attachment 9:
run132_VAMOS_1_10.png
Attachment 10:
run132_VAMOS_1_11.png
Attachment 11:
run132_VAMOS_1_12.png
Attachment 12:
run132_Mugast_1.png
Attachment 13:
run132_Mugast_2.png
Attachment 14:
run132_Mugast_3.png
Attachment 15:
run132_Mugast_4.png
Attachment 16:
run132_Mugast_5.png
Attachment 17:
run132_Mugast_6.png
Attachment 18:
run132_Mugast_7.png
Attachment 19:
run132_Mugast_8.png
Fixed
e744s
Tue Apr 16 03:55:38 2019
louis, Guiseppe
ONLINE
General
CH2
Log and scalers RUN 132 @4:00
Internal trip at 3:37...fixed
Attachment 1:
run132_scaler_1.png
Attachment 2:
run132_VAMOS_2_2.png
Attachment 3:
run132_VAMOS_2_3.png
Attachment 4:
run132_VAMOS_2_4.png
Attachment 5:
run132_VAMOS_2_5.png
Attachment 6:
run132_VAMOS_2_6.png
Attachment 7:
run132_VAMOS_2_7.png
Attachment 8:
run132_VAMOS_2_9.png
Attachment 9:
run132_VAMOS_2_10.png
Attachment 10:
run132_VAMOS_2_11.png
Attachment 11:
run132_VAMOS_2_12.png
Attachment 12:
run132_Mugast_2_1.png
Attachment 13:
run132_Mugast_2_2.png
Attachment 14:
run132_Mugast_2_3.png
Attachment 15:
run132_Mugast_2_4.png
Attachment 16:
run132_Mugast_2_5.png
Attachment 17:
run132_Mugast_2_6.png
Attachment 18:
run132_Mugast_2_7.png
Attachment 19:
run132_Mugast_2_8.png
Fixed
e744s
Tue Apr 16 05:53:00 2019
louis, Guiseppe
ONLINE
General
CH2
Log and scalers RUN 132 @6:00
Over-current on CATS2 is quite frequent. Clean spectra at 6:00
Attachment 1:
run132_scaler_2.png
Attachment 2:
run132_VAMOS_3_2.png
Attachment 3:
run132_VAMOS_3_3.png
Attachment 4:
run132_VAMOS_3_4.png
Attachment 5:
run132_VAMOS_3_5.png
Attachment 6:
run132_VAMOS_3_6.png
Attachment 7:
run132_VAMOS_3_7.png
Attachment 8:
run132_VAMOS_3_9.png
Attachment 9:
run132_VAMOS_3_10.png
Attachment 10:
run132_VAMOS_3_11.png
Attachment 11:
run132_VAMOS_3_12.png
Attachment 12:
run132_Mugast_3_1.png
Attachment 13:
run132_Mugast_3_2.png
Attachment 14:
run132_Mugast_3_3.png
Attachment 15:
run132_Mugast_3_4.png
Attachment 16:
run132_Mugast_3_5.png
Attachment 17:
run132_Mugast_3_6.png
Attachment 18:
run132_Mugast_3_7.png
Attachment 19:
run132_Mugast_3_8.png
Goto page
Previous
1
,
2
,
3
...
6
, 7,
8
...
130
,
131
,
132
Next
ELOG Home Page