Fixed, e793s, Mon Mar 8 18:15:07 2021, mugast, GRIT, General, N/A, Run 634 - TACs calibration (part 4) 
TAC calibration.

AGATA-CATS2 (range 200 ns)
Fixed, e793s, Tue Mar 9 10:22:16 2021, mugast, DAQ, Hardware, N/A, U2M scaler configuration 
U2M

1-FAG
Fixed, e793s, Tue Mar 9 10:47:12 2021, mugast, DAQ, Hardware, N/A, GMT config 
GMT

1-MUVI1
Fixed, e793s, Wed Mar 10 19:23:37 2021, mugast, OFFLINE, General, CD2, Kinematics and Ex - RUN051 RUN51_ELabThethaLab_Ex.pngRUN51_ELabThethaLab_Ex_Egamma.png
Preliminary analysis results, Backward angles.

MM5 position are incorrect
Pending, e793s, Thu Mar 11 09:02:20 2021, mugast, BEAM, Hardware, CD2, beam interruption 
power supply trip on the accelerator beam is off for about 30min
Fixed, e793s, Thu Mar 11 11:07:05 2021, mugast, OFFLINE, General, CD2, run53 - Egamma vs Ex Egamma_vs_Ex_run53.png
 
Fixed, e793s, Thu Mar 11 15:48:14 2021, mugast, OFFLINE, General, N/A, Beam energy and Beta 
Beam energy entering G1:    7.6922 MeV/u (Beta= 0.1277)

CATS2 thickness: 2.8 um of Mylar in total + about 4 cm of isobutane at 4 mbar
Fixed, e793s, Fri Mar 12 10:07:29 2021, mugast, MECH, Hardware, , Leak 

https://www.hometree.co.uk/energy-advice/home-cover/common-water-leaks-and-how-to-fix-them.html
Fixed, e793s, Fri Mar 12 20:54:30 2021, mugast, RUN, General, CD2, summary of run 61 scalers.pngvamos.pngScreenshot_from_2021-03-12_20-57-53.pngScreenshot_from_2021-03-12_20-58-15.pngScreenshot_from_2021-03-12_20-58-45.png
 
Fixed, e793s, Mon Mar 15 02:08:19 2021, mugast, BEAM, General, CD2, Beam stopped at 2:08 
Beam stopped at 2h08. The PCP want to make some measurement on the source to get its statues. Should take about 10 min.
Fixed, e793s, Mon Mar 22 18:15:50 2021, mugast, RUN, General, N/A, TACS calibration - run 662 
TACS:

    FAG-CATS2 (range 500 ns)
Fixed, e793s, Mon Mar 22 19:04:55 2021, mugast, RUN, General, N/A, TACS calibration - run 653 
TACS:

MUGAST-AGATA (range 2 us)
Fixed, , Thu Mar 28 18:29:04 2019, marlene valerian, GRIT, General, 3-alpha, RUN 147 3alpha source overnight all detectors -4deg 
[SIZE=3]RUN 147  start@ 18:30

3 alpha source over night
, , Mon Apr 15 20:42:47 2019, marlene iulian beyhan valĂ©rian, , , ,  
 
Fixed, com2019, Tue Apr 2 16:24:06 2019, marlene freddy, OTHER, General, N/A, Commissioning proposal MUGAST_commissioning-3.pdf
 
Fixed, , Tue Mar 19 19:35:53 2019, marlene, GRIT, General, , RUN 98 3alpha source all detectors 
RUN 98
3 alpha source
all detectors (trap,square, MUST2,annular)
Fixed, e744s, Tue Apr 16 00:01:43 2019, louis, Guiseppe, ONLINE, General, CH2, Online snapshot from run 132 20x
Online snapshot from run 132
Fixed, e744s, Tue Apr 16 01:55:29 2019, louis, Guiseppe, ONLINE, General, CH2, Log & Scalers -- Run 132 at 2:00 19x
Some of the spectra for VAMOS (in particular DC_EWIRE and IC_SUMMARY) disappeared
Fixed, e744s, Tue Apr 16 03:55:38 2019, louis, Guiseppe, ONLINE, General, CH2, Log and scalers RUN 132 @4:00 19x
Internal trip at 3:37...fixed
Fixed, e744s, Tue Apr 16 05:53:00 2019, louis, Guiseppe, ONLINE, General, CH2, Log and scalers RUN 132 @6:00 19x
Over-current on CATS2 is quite frequent. Clean spectra at 6:00   