MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 78 of 127  Not logged in MUGAST
Fixed, e768s, Fri Jul 19 00:03:25 2019, Jenn, BEAM, General, , Brho information 15 Oxygen beam 4.7MeV/u 
 
Fixed, e768s, Fri Jul 19 00:06:35 2019, Jenn, BEAM, General, , Brho information 15 Oxygen beam 4.7MeV/u New_Doc_2019-07-18_23.58.18_1.pdf
 
Fixed, e768s, Fri Jul 19 00:08:13 2019, OttoRun, RUN, General, N/A, Run104 
*************************
  [SIZE=3][B]Run  : 104[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 00:08:51 2019, OttoRun, RUN, General, N/A, Run105 run_105-15O-beamspot-optimization.pngIMG_20190719_010634_crop.jpg
*************************
  [SIZE=3][B]Run  : 105[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 00:59:00 2019, OttoRun, RUN, General, LiF, Run106 
*************************
  [SIZE=3][B]Run  : 106[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 00:59:20 2019, mugast, RUN, General, , RUN 107 - Reference Target Run 
Reference Target Run after beam tuning
Brho 0.5854 Tm
Fixed, e768s, Fri Jul 19 01:02:54 2019, mugast, OTHER, General, , 15O beam parameters 
Brho manip = Brho after target - 2% = 0.556 Tm

RMN = 2821.476 Gauss
Fixed, e768s, Fri Jul 19 01:05:26 2019, mugast, RUN, General, , RUN 108  
Brho Change to 0.556 Tm 

Moving Plate : Final Position +7mm
Fixed, e768s, Fri Jul 19 01:32:17 2019, OttoRun, RUN, General, LiF, Run107 
*************************
  [SIZE=3][B]Run  : 107[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 01:32:20 2019, OttoRun, RUN, General, LiF, Run108 
*************************
  [SIZE=3][B]Run  : 108[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 02:19:51 2019, OttoRun, RUN, General, LiF, Run110 
*************************
  [SIZE=3][B]Run  : 110[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 02:22:12 2019, OttoRun, RUN, General, LiF, Run111 
*************************
  [SIZE=3][B]Run  : 111[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 02:27:22 2019, OttoRun, RUN, General, LiF, Run112 
*************************
  [SIZE=3][B]Run  : 112[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 03:29:58 2019, Jenn, ONLINE, General, LiF, Screenshots run 112 overnight 16x
MUGAST and VAMOS screenshots run 112
Fixed, TEST, Fri Jul 19 05:23:04 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY 
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE] 
 [SIZE=2][COLOR=green]+10v/mg     [/COLOR] Slot: [COLOR=blue]5  [/COLOR] (A1516B) Channel:[COLOR=blue]5 [/COLOR]  Vmon: [COLOR=blue]   10 V  [/COLOR] Imon:
[COLOR=blue]0.408 A [/COLOR] Status: [COLOR=green]On[/COLOR]
Fixed, TEST, Fri Jul 19 05:23:05 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY 
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE] 
 [SIZE=2][COLOR=green]            [/COLOR] Slot: [COLOR=blue]8  [/COLOR] (A1821H) Channel:[COLOR=blue]1 [/COLOR]  Vmon: [COLOR=blue]    0 V  [/COLOR] Imon:
[COLOR=blue]0.001 uA[/COLOR] Status: [COLOR=pink]Off[/COLOR]
Fixed, e768s, Fri Jul 19 08:09:21 2019, Jenn, Kseniia, OTHER, General, , Overview nightshift run 112 
Smooth night, everything was working properly.
Checked agata rootfile to see preliminary gammas.
Fixed, e768s, Fri Jul 19 09:32:45 2019, mugast, BEAM, General, LiF, Beam is fluctuating run_113_temporary_beam_loss.png
There was a temporary beam loss during the run 113
Fixed, e768s, Fri Jul 19 09:38:05 2019, mugast, GRIT, General, LiF, Impact matrix for MUGAST mugast_missing_strip.png
 
Fixed, e768s, Fri Jul 19 10:35:05 2019, OttoRun, RUN, General, LiF, Run113 
*************************
  [SIZE=3][B]Run  : 113[/B][/SIZE]
*************************

ELOG Home Page