Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e744s |
Fri Apr 12 01:37:24 2019 |
OttoRun | RUN | General | Empty | Run85 |
*************************
Run : 85
*************************
Start at 2019-04-12 01:37:03.553133
Run Conditions:
- Operator: Adrien
- Trigger: VAMOS %1
- Target/Source: hole target 1
- Beam: 14O
- Intensity: ~ 4e+4
- Brho = 0.69186 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Aligning beam in VAMOS, restart after crash of the aquisition |
Fixed | e744s |
Fri Apr 12 01:50:50 2019 |
OttoRun | RUN | General | Empty | Run86 |
*************************
Run : 86
*************************
Start at 2019-04-12 01:49:22.775057
Run Conditions:
- Operator: Jenn
- Trigger: VAMOS %1
- Target/Source: hole target 1
- Beam: 14O
- Intensity: ~ 4e+4
- Brho = 0.6912 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start CATS and target 1 hole
Stop at 2019-04-12 01:59:01.799964
Stop comment: type your message here |
Fixed | e744s |
Fri Apr 12 01:56:35 2019 |
Jenn, Louis, Cyril,Daniele and Chloe | BEAM | General | Empty | Brho for the new 14O setting RUN86 |
CATS2 on and target position 1: hole
Beam intensity in CATS: 4E4
VAMOS intensity 1.3E4
CATS2 off and target position 1 = hole
Beam intensity in VAMOS = 4e4 pps (~100% transmission) |
Fixed | |
Fri Apr 12 02:05:34 2019 |
François, Chloé | TARGET | General | | Target change |
Changed from Target 1 hole to Target 2 (104microns). |
Fixed | e744s |
Fri Apr 12 02:23:57 2019 |
OttoRun | RUN | General | CH2 | Run87: First physics run of 14O |
*************************
Run : 87
*************************
Start at 2019-04-12 02:20:23.557408
Run Conditions:
- Operator: Jenn
- Trigger: MG Backward, MG90, MUST2, CATS %1000 AGATA %100
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: ~ 4e+4
- Brho = 0.6912 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is closed.
Stop at 2019-04-12 06:23:53.544073
Stop comment: type your message here |
Fixed | e744s |
Fri Apr 12 06:24:31 2019 |
OttoRun | RUN | General | CH2 | Run88 |
========================================
*************************
Run : 88
*************************
Start at 2019-04-12 06:24:07.821497
Run Conditions:
- Operator: Louis
- Trigger: MG Backward, MG90, MUST2, CATS %1000 AGATA %100
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: ~ 3e+4
- Brho = 0.6912 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is closed.
Stop at 2019-04-12 08:37:19.321598
Stop comment: Stop to setup VAMOS |
Fixed | e744s |
Fri Apr 12 06:51:59 2019 |
Louis | BEAM | General | N/A | Brho and energy of the 14O beam |
|
Fixed | e744s |
Fri Apr 12 07:26:29 2019 |
iulian | RUN | General | CH2 | Run88 |
Please add all the spectra from the visualization into the elog and all the scales.... see runs before
OttoRun wrote: | *************************
Run : 88
*************************
Start at 2019-04-12 06:24:07.821497
Run Conditions:
- Operator: Louis
- Trigger: MG Backward, MG90, MUST2, CATS %1000 AGATA %100
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: ~ 3e+4
- Brho = 0.6912 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is closed. |
|
Fixed | e744s |
Fri Apr 12 08:01:12 2019 |
valerian | RUN | General | CH2 | run 88 screenshots |
|
Fixed | e744s |
Fri Apr 12 08:19:31 2019 |
Marlène | OFFLINE | General | | CATS profiles RUN87 |
|
Fixed | e744s |
Fri Apr 12 09:01:28 2019 |
OttoRun | RUN | General | CH2 | Run90 |
*************************
Run : 90
*************************
Start at 2019-04-12 09:00:41.342650
Run Conditions:
- Operator: Louis
- Trigger: MVAMOS
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Stop at 2019-04-12 09:05:00.469744
Stop comment: STop due TO ganlx7 crash TCP.Error on VAMOS_VME Entering to reboot CPU |
Fixed | e744s |
Fri Apr 12 09:12:52 2019 |
OttoRun | RUN | General | CH2 | Run91 |
*************************
Run : 91
*************************
Start at 2019-04-12 09:12:29.222765
Run Conditions:
- Operator: Louis
- Trigger: MVAMOS
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
After rebboting ganlx7 (VAMOS_VME)
Stop at 2019-04-12 09:32:38.858638
Stop comment: |
Fixed | e744s |
Fri Apr 12 09:25:10 2019 |
Marlène | ONLINE | General | | TAC |
|
Fixed | e744s |
Fri Apr 12 09:33:33 2019 |
OttoRun | RUN | General | CH2 | Run92 |
*************************
Run : 92
*************************
Start at 2019-04-12 09:33:19.869189
Run Conditions:
- Operator: Louis
- Trigger: MUST2
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
After rebboting ganlx7 (VAMOS_VME)
Stop at 2019-04-12 09:37:30.065218
Stop comment: Start did not Start ! |
Fixed | e744s |
Fri Apr 12 09:37:43 2019 |
OttoRun | RUN | General | CH2 | Run93 |
*************************
Run : 93
*************************
Start at 2019-04-12 09:37:36.997465
Run Conditions:
- Operator: Louis
- Trigger: MUST2
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open |
Fixed | e744s |
Fri Apr 12 09:41:38 2019 |
OttoRun | RUN | General | CH2 | Run94 |
*************************
Run : 94
*************************
Start at 2019-04-12 09:41:27.977232
Run Conditions:
- Operator: Louis
- Trigger: MUGAST + Vamos
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Stop at 2019-04-12 10:11:29.453680 |
Fixed | e744s |
Fri Apr 12 10:17:57 2019 |
OttoRun | RUN | General | CH2 | Run95 |
*************************
Run : 95
*************************
Start at 2019-04-12 10:09:45.911078
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
working inside G1
Stop at 2019-04-12 10:33:06.491018
Stop comment: |
Fixed | e744s |
Fri Apr 12 10:36:09 2019 |
Valerian | RUN | General | N/A | Procedure to follow during runs |
At the beginning of a run :
- Do screenshots of the scalers and add them to the elog.(Say it is at the beginning of the run)
During a run, one should :
- Check regularly the scalers.
- Look at the different pages on vigru.
- Check if there are any problem concerning the Voltages, a window should be prompted to you if it is the case. If the window has FP written it is on the VAMOS side.
- Do conversion, see corresponding entry (Or paper next to computer)
- Check the last pending issues in the elog and if they are fixed, edit them to fix (any HV trip or over-current are pending and shoudl be switch to fix).
Every hours and before stopping the run:
- Do screenshots of the scalers and add them to the elog.(Say at which time it is done)
- Do screenshots of all the vigru pages of MUGAST and VAMOS and add them to the elog.
|
Fixed | e744s |
Fri Apr 12 10:37:03 2019 |
OttoRun | RUN | General | CH2 | Run96 |
*************************
Run : 96
*************************
Start at 2019-04-12 10:36:45.359601
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Timing Setting
Stop at 2019-04-12 11:16:49.078211
Stop comment: Entering Change Delay on T_FPMW_CATS2 |
Fixed | e744s |
Fri Apr 12 11:29:46 2019 |
OttoRun | RUN | General | CH2 | Run97 |
*************************
Run : 97
*************************
Start at 2019-04-12 11:29:03.948068
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Correct TAC T_FPMW_XXX FPMW Fifo Pb with 50 ohm terminator ...
Stop at 2019-04-12 11:45:25.662355
Stop comment: Entering to Set Vamos %100 |