MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 6 of 132
Not logged in
Find
|
Login
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
5
, 6,
7
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
TEST
Tue Feb 18 10:00:40 2020
mugast
RUN
General
3-alpha
RUN 501 - missing info
RUN 501
alpha run with cooling during the night from
Fixed
e775s
Mon Feb 24 17:14:57 2020
mugast
RUN
General
CD2
RUN 124
*************************
Run : 124
*************************
Fixed
e775s
Tue Feb 25 15:09:58 2020
mugast
GRIT
General
Screenshots run 131
6x
Fixed
Wed Feb 26 15:04:29 2020
mugast
RUN
General
beam retuning
Beam is retuned from PCP to improve its quality
Fixed
e775s
Thu Feb 27 11:53:34 2020
mugast
RUN
General
run 140
Start at 11h41 (Feb. 27th)
Stop at (Feb. 27th)
Fixed
e775s
Thu Feb 27 15:51:03 2020
mugast
RUN
General
RUN 140
Target CD2 thin target
Beam intensity ~ 5e+5 pps
Fixed
e775s
Thu Feb 27 19:35:26 2020
mugast
RUN
General
CD2
Run 142 : beam stopped
Beam stopped at 19h20 : drift of beam line
hit a neutron watcher in one of G1 neighboring
rooms, radiosecurity
Fixed
e775s
Fri Feb 28 08:26:37 2020
mugast
RUN
General
CD2
RUN142/143 MUGAST Spectra 8h30
Fixed
e775s
Fri Feb 28 11:49:46 2020
mugast
RUN
General
CD2
RUN 142/143 preliminary analysis with gamma
Ongoing
e775s
Sat Feb 29 03:26:52 2020
mugast
RUN
General
N/A
Continues RUN 153
Run 153 (target #2 CD2+Au)
Beam Intensity 4*10⁵
Fixed
e793s
Wed Mar 11 19:02:54 2020
mugast
GRIT
General
3-alpha
Alpha calibration for e793s - run 600
========================================
========================================
========================================
Fixed
e793s
Wed Mar 11 22:01:18 2020
mugast
GRIT
General
3-alpha
Alpha calibration - run 600
After 2h30' of run we checked the temperatures
of the boards and we noticed that MG7 had
63 degrees on both X and Y, which is very
Fixed
e793s
Thu Mar 12 17:25:19 2020
mugast
GRIT
General
3-alpha
run 0601 - alpha source with pedestals
Alpha source calibration run without pedestal
suppression and cooling at 0 deg.
Tue May 19 12:23:57 2020
mugast
ONLINE
Fixed
e793s
Fri Feb 12 08:52:30 2021
mugast
RUN
General
3-alpha
run 613: long alpha run
all Muvi in trigger, mugast stand alone. all
detector Bias on.
Fixed
e793s
Fri Mar 5 16:16:28 2021
mugast
DAQ
Software
Pedestals for E793S
Pedestal alignment was performed for Energy
qnd Time for all cards with cooling at 0°.
12x
Fixed
e793s
Fri Mar 5 17:01:27 2021
mugast
S1
Hardware
N/A
Giving up on S1
We mounted the new S1 detector from Surrey
with a new custom cable on several MUFEE
cards using the CsI ASICs.
Fixed
e793s
Mon Mar 8 17:21:14 2021
mugast
GRIT
General
N/A
Run631 - TACs calibration (part 1)
*************************
[SIZE=3][B]Run : 631[/B][/SIZE]
*************************
Fixed
e793s
Mon Mar 8 17:47:29 2021
mugast
GRIT
General
N/A
Run632 - TACs calibration (part 2)
TAC calibration.
VAMOS-CATS2 (range 2 us)
Fixed
e793s
Mon Mar 8 18:07:25 2021
mugast
GRIT
General
N/A
Run 633 - TACs calibration (part 3)
TAC calibration.