MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 6 of 132  Not logged in MUGAST
Fixed, TEST, Tue Feb 18 10:00:40 2020, mugast, RUN, General, 3-alpha, RUN 501 - missing info 
RUN 501

alpha run with cooling during the night from 13-14/02/2020
Fixed, e775s, Mon Feb 24 17:14:57 2020, mugast, RUN, General, CD2, RUN 124 run124_Tof.png
*************************
Run : 124
*************************
Fixed, e775s, Tue Feb 25 15:09:58 2020, mugast, GRIT, General, , Screenshots run 131 6x
 
Fixed, , Wed Feb 26 15:04:29 2020, mugast, RUN, General, , beam retuning 
Beam is retuned from PCP to improve its quality
Fixed, e775s, Thu Feb 27 11:53:34 2020, mugast, RUN, General, , run 140 
Start at 11h41 (Feb. 27th)
Stop  at  (Feb. 27th)
Fixed, e775s, Thu Feb 27 15:51:03 2020, mugast, RUN, General, , RUN 140 
 Target CD2 thin target
Beam intensity ~ 5e+5 pps
Fixed, e775s, Thu Feb 27 19:35:26 2020, mugast, RUN, General, CD2, Run 142 : beam stopped 
Beam stopped at 19h20 : drift of beam line hit a neutron watcher in one of G1 neighboring rooms, radiosecurity
protocol started.
On call team must come : estimation beam back on in 30min.
Fixed, e775s, Fri Feb 28 08:26:37 2020, mugast, RUN, General, CD2, RUN142/143 MUGAST Spectra 8h30 RUN143_ElabThetaLab_8h30.pngRUN143_tac_8h30.pngRUN143_tof_8h30.pngRUN143_impact_8h30.png
 
    Fixed, e775s, Fri Feb 28 11:49:46 2020, mugast, RUN, General, CD2, RUN 142/143 preliminary analysis with gamma ExEg_RUN142full.png
 
Ongoing, e775s, Sat Feb 29 03:26:52 2020, mugast, RUN, General, N/A, Continues RUN 153 RUN153_online0305.pngRUN153_online0306.pngRUN153_online0307.pngRUN153_online0308.pngRUN153_online0309.png
Run 153 (target #2 CD2+Au)

Beam Intensity 4*10⁵
Fixed, e793s, Wed Mar 11 19:02:54 2020, mugast, GRIT, General, 3-alpha, Alpha calibration for e793s - run 600 
========================================
========================================
========================================
    Fixed, e793s, Wed Mar 11 22:01:18 2020, mugast, GRIT, General, 3-alpha, Alpha calibration - run 600 MG7X_run600_Eevolution.png
After 2h30' of run we checked the temperatures of the boards and we noticed that MG7 had 63 degrees on both X and Y, which is very high; MG9 was around
56 on X and 26 on Y. There might be a problem in the loop of the cooling system because the other detectors are pretty fine, with temperatures around 20-25
degrees.
Fixed, e793s, Thu Mar 12 17:25:19 2020, mugast, GRIT, General, 3-alpha, run 0601 - alpha source with pedestals 
Alpha source calibration run without pedestal suppression and cooling at 0 deg.
, , Tue May 19 12:23:57 2020, mugast, ONLINE, , ,  
 
Fixed, e793s, Fri Feb 12 08:52:30 2021, mugast, RUN, General, 3-alpha, run 613: long alpha run  
all Muvi in trigger, mugast stand alone. all detector Bias on.
Fixed, e793s, Fri Mar 5 16:16:28 2021, mugast, DAQ, Software, , Pedestals for E793S 12x
Pedestal alignment was performed for Energy qnd Time for all cards with cooling at 0°. 
The values are attached here and saved in : cd ganacq_manip/mugast/das-save/pedestal-save/pedestal_5march2021_15h54/
Fixed, e793s, Fri Mar 5 17:01:27 2021, mugast, S1, Hardware, N/A, Giving up on S1 
We mounted the new S1 detector from Surrey with a new custom cable on several MUFEE cards using the CsI ASICs.
We managed to put voltage on it and get decent leakage current. 
We modified the DAS parameters from CsI values to Si values (gain, shaping time, etc).
Fixed, e793s, Mon Mar 8 17:21:14 2021, mugast, GRIT, General, N/A, Run631 - TACs calibration (part 1) 
*************************
  [SIZE=3][B]Run  : 631[/B][/SIZE]
*************************
Fixed, e793s, Mon Mar 8 17:47:29 2021, mugast, GRIT, General, N/A, Run632 - TACs calibration (part 2) 
TAC calibration.

    VAMOS-CATS2 (range 2 us)
Fixed, e793s, Mon Mar 8 18:07:25 2021, mugast, GRIT, General, N/A, Run 633 - TACs calibration (part 3) 
TAC calibration.

Mugast-CATS2 (range 1 us)

ELOG Home Page