Fixed  Tue Mar 19 19:35:53 2019 marleneGRITGeneral RUN 98 3alpha source all detectors
RUN 98
3 alpha source
all detectors (trap,square, MUST2,annular)
Temp=15deg
Acquisition mugast
FixedTEST Tue Feb 18 10:00:40 2020 mugastRUNGeneral3-alphaRUN 501 - missing info
RUN 501

alpha run with cooling during the night from 13-14/02/2020
FixedTEST Thu Feb 21 09:08:49 2019 FreddyRUNGeneral3-alphaRUN 30 - alpha on MG 1,3,5,7
Run 30

Alpha source run for trapezoid detectors during the night with pedestals aligned and zero suppression. Cooling at 15°C.
Thresholds at 500 keV.
Run size: 1.3 G

On MUVI1:

1--> MG5 (150V)
2--> --
3--> MG3 (160V)
4--> --

On MUVI2:
5--> MG7 (120V)
6--> MG1 (140V)
7--> --
8--> --

TRIGGERS are:
GMT ch1 --> OR MUVI1
GMT ch2 --> OR MUVI2
GMT ch3 --> OR MUVI3 (nothing on it)

Plots are now represented using the correspondance map which means that it correspond to the geometrical ordering on the detector. With this representation groups of strips missing or disfunctionning on a given region of the detector is more obvious.
Attachment 1: 3alpha_source_MG_1357_20Feb.png
3alpha_source_MG_1357_20Feb.png
Attachment 2: LowV_bis_run30.png
LowV_bis_run30.png
Attachment 3: LowV_run30.png
LowV_run30.png
Attachment 4: HV_run30.png
HV_run30.png
Fixed  Thu Feb 14 15:30:14 2019 Marlene Daniele JennyGRITGeneral3-alphaRUN 28
RUN 28 14th Feb
3 alpha source on MG11A, MG3T, MG1T

GMT channels
MG11
-
MG3
-
-
MG1
-
Attachment 1: 3alpha_sourceMG03XY._OKpng
Attachment 2: 3alpha_sourceMG11XY.png
3alpha_sourceMG11XY.png
Attachment 3: 3alpha_sourceMG01XY_OK.png
3alpha_sourceMG01XY_OK.png
Fixed  Thu Feb 14 08:50:58 2019 MarleneGRITGeneral3-alphaRUN 27
RUN 27 on 14th of feb.
3 alpha source (one in front of trap., one in front of square detectors)

MG10, MG4, MG7 and MG5 are OK.
MG1 shows alpha but at lower energy and with bad resolution (particularly on X). We suspect it is not well depleted. We tried to increase the bias up to 200V but did not see any change.
It is due to a non working SA/SL external cable that produces this error (we tested it with several detectors, we also tried to change the MUVI channel and it still does the same)

Conclusion :
We have tested all trapezoid detectors (MG1, MG3, MG4, MG5, MG7) the annular (MG11) and the thin square (MG10) they are all OK




Detectors (order in the GMT) :
MG10
MG1
MG4
-
MG7
MG5
-
-

attached : bias of detectors ( be careful : MG10 bias = MG11A)
spectra for all detectors
Attachment 1: HV_detectors_MG10_MG1_MG4_MG7_MG5.png
HV_detectors_MG10_MG1_MG4_MG7_MG5.png
Attachment 2: GMT8config_HV_detectors_MG10_MG1_MG4_MG7_MG5.png
GMT8config_HV_detectors_MG10_MG1_MG4_MG7_MG5.png
Attachment 3: 3alpha_sourceMG07X.png
3alpha_sourceMG07X.png
Attachment 4: 3alpha_sourceMG07Y.png
3alpha_sourceMG07Y.png
Attachment 5: 3alpha_sourceMG05XY.png
3alpha_sourceMG05XY.png
Attachment 6: 3alpha_sourceMG10XY.png
3alpha_sourceMG10XY.png
Attachment 7: 3alpha_sourceMG04XY.png
3alpha_sourceMG04XY.png
Attachment 8: 3alpha_sourceMG01XY.png
3alpha_sourceMG01XY.png
Fixede744s Thu Apr 18 09:28:12 2019 MarlèneMUST2General3-alphaRUN 206 (mugast) 3Alpha calib after e744s experiment
RUN 206
3 alpha source all detectors with no change in the configuration (low thresholds in MUST2)
From 17/04 18h13 -> 18/04 9h31
Attachment 1: run206_calibMMY.png
run206_calibMMY.png
Attachment 2: run206_calibMGY.png
run206_calibMGY.png
Attachment 3: run206_calibMMX.png
run206_calibMMX.png
Attachment 4: run206_calibMGX.png
run206_calibMGX.png
FixedTEST Mon Mar 18 18:31:18 2019 valerian marlèneGRITGeneral3-alphaRUN 20 (com2019) 3 alpha overnight
RUN20

Run with double 3alpha source MUST2+MG1_7+MG11
temperature -4 deg on both cooling

Acquisition with VAMOS+MUGAST coupled (com2019)

Time range =600ns
pedestal aligned and suppressed

run start at 18h23 monday 18

run stop at 8h34 tuesday 19

about 12Go of data
Attachment 1: RUN20_HV_MG_3lapha.png
RUN20_HV_MG_3lapha.png
Attachment 2: RUN20_3alpha_HV_MUST2.png
RUN20_3alpha_HV_MUST2.png
Fixede775s Fri Feb 28 14:00:08 2020 MarlèneRUNGeneral RUN 151 beam stop

Marlène wrote:
RUN 151

Change of target now : CD2+AU #2
Beam intensity : 4e+5pps



beam stopped due to unstable equipment in CSS1.
expected duration : 15 min
Fixede775s Fri Feb 28 11:21:31 2020 MarlèneRUNGeneral RUN 151
RUN 151

Change of target now : CD2+AU #2
Beam intensity : 4e+5pps
Fixed  Fri Feb 28 11:20:22 2020 MarlèneGRITGeneral RUN 150
RUN 150
target CD2 300 ug/cm2
Beam intensity 4e+5pps

Note that there is no 144,145,146,147, 148 ans 149 runs
Fixed  Thu Mar 28 18:29:04 2019 marlene valerianGRITGeneral3-alphaRUN 147 3alpha source overnight all detectors -4deg
RUN 147 start@ 18:30

3 alpha source over night

cooling at -4 deg on all detectors

warning !!! FIFO for BLK signal has been put in 4x4 instead of 2x8, BLK is only coming from the 3 VXI of MUGAST
Fixede775s Fri Feb 28 11:49:46 2020 mugastRUNGeneralCD2RUN 142/143 preliminary analysis with gamma
Attachment 1: ExEg_RUN142full.png
ExEg_RUN142full.png
Fixed  Thu Feb 27 16:25:45 2020 MarlèneRUNGeneral RUN 142-143 screenshots

Marlène wrote:
RUN142 on AGATA and RUN143 on MUGAST/VAMOS

target CD2 (350ug/cm2)
Trigger MUGAST
Beam intensity : 5e+5pps



!!!! there is a shift in the run number on AGATA with respect to VAMOS/MUGAST
Attachment 1: RUN143_ElabThetaLab.png
RUN143_ElabThetaLab.png
Attachment 2: RUN143_impact.png
RUN143_impact.png
Attachment 3: RUN143_tac.png
RUN143_tac.png
Attachment 4: RUN143_tof.png
RUN143_tof.png
Fixed  Thu Feb 27 15:56:09 2020 MarlèneRUNGeneral RUN 142 AGATA- 143 VAMOS-MUGAST
RUN142 on AGATA and RUN143 on MUGAST/VAMOS

target CD2 (350ug/cm2)
Trigger MUGAST
Beam intensity : 5e+5pps



!!!! there is a shift in the run number on AGATA with respect to VAMOS/MUGAST
Fixed  Thu Feb 27 16:30:53 2020 MarlèneRUNGeneral RUN 142 -143 preliminary analysis

Marlène wrote:

Marlène wrote:
RUN142 on AGATA and RUN143 on MUGAST/VAMOS

target CD2 (350ug/cm2)
Trigger MUGAST
Beam intensity : 5e+5pps



!!!! there is a shift in the run number on AGATA with respect to VAMOS/MUGAST
Attachment 1: RUN143_ana_Elab_Thetalab.png
RUN143_ana_Elab_Thetalab.png
Attachment 2: RUN143_ana_Ex_Eg.png
RUN143_ana_Ex_Eg.png
Attachment 3: RUN143_ana_Ex.png
RUN143_ana_Ex.png
Fixed  Thu Feb 27 15:54:09 2020 Marlène RUNGeneral RUN 141 junk (problem at start)
Fixede775s Thu Feb 27 15:51:03 2020 mugastRUNGeneral RUN 140
Target CD2 thin target
Beam intensity ~ 5e+5 pps


to check the gammas from 20O
Fixede775s Wed Feb 26 16:19:35 2020 MarlèneRUNGeneral RUN 137 (suite)
Here is the E gamma versus Excitation energy spectra for run 137



Marlène wrote:
RUN 137
CD2+Au #2
beam intensity 6e+5pps

beam was retuned during the night, seems to be degraded although intensity is higher.
Attachment 1: Ex_Egamma_run137.png
Ex_Egamma_run137.png
Fixed  Wed Feb 26 14:31:47 2020 Fairouz, Nicolas, MarlèneGRITGeneral RUN 137
Run 137
CD2+Au #2
Beam intensity 6e+5pps on average

Beam was retuned during the night and the quality of the beam is probably degraded
Fixede775s Wed Feb 26 15:02:38 2020 MarlèneRUNGeneral RUN 137
RUN 137
CD2+Au #2
beam intensity 6e+5pps

beam was retuned during the night, seems to be degraded although intensity is higher.
Attachment 1: Ex_137.pdf
Ex_137.pdf
Attachment 2: Ex_run128_137.pdf
Ex_run128_137.pdf