MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 61 of 132  Not logged in MUGAST
Status ExpNbr Date Author Type Category Target-Source Subjectdown Text Attachments
Fixede744s Tue Apr 16 11:44:10 2019 Marion, DieterTARGETGeneralCarbonRun 133. Carbon target in 60 microns. Setting up.    
Fixedcom2019 Thu Apr 4 08:31:58 2019 mugastRUNGeneralN/ARun 129Run 129 overnight vamos calibration.
Multiple trip of FP_CATSXXX between and 5.09
and 6.35
  
Fixede744s Mon Apr 15 09:36:01 2019 Nikola Marion Kseniia Damien Chloe Marlene FairouzRUNGeneralCH2Run 125 stopped 9:30 to go back to on-resonance config   run125_2_scaler_8_end.png 
Fixede768s Mon Jul 22 13:40:41 2019 FranckONLINEGeneralLiFRun 125 screenshots   22x 
Fixede768s Mon Jul 22 06:14:38 2019 Faïrouz & SylvainRUNGeneralLiFRun 122 with more centered beam profileEven with a more centered beam profile, AGATA
request triggers is increasing too much and
too fast!!! after 5 mn run, we are already
 Beam-profile-run122-06h13.jpgScalers-run122-06h13.jpg 
Fixede768s Mon Jul 22 02:07:44 2019 Faïrouz & SylvainBEAMGeneralLiFRun 121 : Beam profile Status at 2:05 AM   Beam-profile-run121-02h05.jpgScaler-run121-02h05.jpg 
Fixede768s Sun Jul 21 11:49:59 2019 Christiqn qnd DidierRUNGeneralLiFRun 119 screenshots   run_119_ICIC_MMETOF.pngrun_119_scaler_grqph.pngrun_119_scalers.png 
Fixede768s Sat Jul 20 23:43:02 2019 mugastRUNGeneralLiFRun 119 (Problem with VXI fixed for the moment) Run 119.
Or-Vamos= 1430 ---> I=1.43x10^7 pps
 scaler_run119_1.png 
Fixede768s Sat Jul 20 21:10:57 2019 Faïrouz & SylvainRUNGeneralLiFRun 118 stopped because VXI Vamos turned offline because of overheat Run 118 stopped because VXI Vamos turned offline
of overheat
  
Fixede768s Sat Jul 20 19:12:58 2019 Faïrouz & SylvainRUNGeneralLiFRun 118 screenshots @ 19h14   20x 
Fixede768s Sat Jul 20 17:06:12 2019 mugastRUNGeneralLiFRun 118 ScalerStart run 118   scaler_run118_1.png 
Fixede768s Sat Jul 20 17:03:23 2019 mugastRUNGeneralLiFRun 117 stoppedRun 117 stopped because VAMOS VXI went offline   
Fixede768s Fri Jul 19 17:15:46 2019 mugastRUNGeneralLiFRun 116   run116-Scaler2.png 
Fixede793s Thu Mar 12 14:54:13 2020 Marlène & FrancoGRITGeneral3-alphaRun 0601 - alpha source calibrationWe start the alpha source calibration run
with pedestal suppression (except for MG7
and MG9) and cooling at 0 deg.
 HV_run601.png 
FixedTEST Thu Feb 21 14:37:26 2019 iulian, valerian &FreddyGRITHardware3-alphaResults Calibration 3-alpha RUN30 MG1, MG3,MG5 & MG7Results of the calibration run 30
In order:
 Telescope1 X,Y (MG5 X,Y)
 8x 
FixedTEST Wed Jan 23 09:11:26 2019 Valérian-MarlèneGRITGeneral3-alphaRUN9 : 3 alpha source run on MG10C & MG3T[B]RUN 9 (over night 22/01 ->23/01)[/B]
3 alpha source (not centered)
MG10C and MG3T ON
 3alpha_sourceMG10C-MM2_MG3T-MM3.pngHV_squares_plugged_on_MG4T-MG5T_andMG3T.pngHV_squares_plugged_on_MG4T-MG5T_andMG3T_afternightrun.pngMG10C_7missingstrips.png 
FixedTEST Mon Mar 4 16:24:51 2019 valerian marlèneGRITGeneral RUN52 3 alpha source 4MUST2 no pedestalRUN52 
3 alpha source run with only 4MUST2 (in MUVI3)
with pedestal suppression at 13 deg.
 HV_MUST2_during_run52.pngHV_MUST2_afternightrun52.png3alpha_source_4MUST2_nightrun52.png 
Fixede775s Fri Feb 28 08:26:37 2020 mugastRUNGeneralCD2RUN142/143 MUGAST Spectra 8h30   RUN143_ElabThetaLab_8h30.pngRUN143_tac_8h30.pngRUN143_tof_8h30.pngRUN143_impact_8h30.png 
Fixede775s Thu Feb 27 12:35:39 2020 Marlène NicolasGRITGeneral RUN128-137_138 analysisKinematic lines for the full statistics up
to now
States above E*>7 MeV are cut in the angles
 Elab_Thetalab_RUN128_137_138.pngExEg_RUN128_137_139.pngEx_RUN128_137_138.png 
FixedTEST Thu Feb 7 09:52:08 2019 Freddy, MarlèneRUNGeneral3-alphaRUN10 : 3 alpha source on MG1-3-4-5-7Test run with alpha source in front of trapezoid
detectors.
 alpha_source_5trap_rawhistos_2.pngalpha_source_5trap_rawhistos.png 

ELOG Home Page