Fixed, e786s, Fri Jun 28 04:21:48 2019, Daniele Mengoni, RUN, General, Cryo-3He, run 74 18x
|
screenshots run 74 attached
frequent error message on the FP DC Wi1 --> defqlt. The elog said so, card tripped, but spectra are still present .. puzzling |
Fixed, e786s, Fri Jun 28 08:54:50 2019, Freddy, RUN, General, Cryo-3He, run 74
|
[quote="Daniele Mengoni"]screenshots run 74 attached
frequent error message on the FP DC Wi1 --> defqlt. The elog said so, card tripped, but spectra are still present .. puzzling[/quote]
|
Fixed, e793s, Wed Mar 17 10:23:44 2021, Cyril, RUN, General, CD2, run 64 screenshots at 10h05 - End of e793s 8x
|
The beam/acq has been stopped around 10h05. |
Fixed, e793s, Wed Mar 17 07:52:37 2021, Laetitia, Charlie, RUN, General, CD2, run 64 screenshots at 07h45 10x
|
|
Fixed, e793s, Wed Mar 17 05:49:02 2021, Laetitia, Charlie, RUN, General, CD2, run 63 screenshots at 05h45 9x
|
|
Fixed, e793s, Sat Mar 13 12:07:32 2021, Lynda, Laetitia, Chloe, ONLINE, General, CD2, run 62 screenshots at 11h55 10x
|
|
Fixed, e793s, Mon Mar 15 06:59:02 2021, Sarah, Louis, Charlie, RUN, General, CD2, run 62 screenshots at 06h55 8x
|
Screenshots attached. Note that the fluctuation issues have returned after the "electrostatic trip"(?) but the beam pps remain pretty high. |
Fixed, e793s, Mon Mar 15 04:57:32 2021, Sarah, Louis, Charlie, RUN, General, CD2, run 62 screenshots at 04h50 8x
|
The beam intensity has been surprisingly high so far, [URL=https://caeelog.in2p3.fr/MUGAST/6147]considering the news we were given[/URL] about the source
a few hours ago. It has just taken a dip to ~4.5e5 in the last 10 mins or so. |
Fixed, e786s, Wed Jun 26 20:46:20 2019, Sylvain, Louis, RUN, General, Cryo-3He, run 62 screenshots 18x
|
|
Fixed, e793s, Fri Feb 12 08:52:30 2021, mugast, RUN, General, 3-alpha, run 613: long alpha run
|
all Muvi in trigger, mugast stand alone. all detector Bias on. |
Fixed, TEST, Tue Mar 5 12:13:41 2019, iulian Marlene, MUST2, Software, N/A, run 60 Gamme 600 ns Time Calibration run (Calimero) on MUVI 3 MM1 X 
|
RUNS 58,59,60 are bad runs
[U][B]Run 61[/B][/U]
|
Fixed, TEST, Tue Mar 5 10:16:03 2019, iulian, MUST2, Software, N/A, run 57 Gamme 300 ns Time Calibration run (Calimero) on MUVI 3 (MUST) X sectors more stats (10000) 
|
RUNS 53,54,55,56 are bad runs
[U][B]Run 57[/B][/U]
|
Fixed, e793s, Thu Mar 11 17:32:07 2021, Faïrouz, Franco, Sarah, RUN, General, CD2, run 56 screenshots 17h30 8x
|
|
Fixed, e793s, Thu Mar 11 15:26:37 2021, Nicolas, Lynda, Charlie, Sarah, RUN, General, CD2, run 56 screenshots 15h30 8x
|
online histograms reset around 15h45 |
Fixed, e786s, Mon Jun 24 20:39:54 2019, Freddy, RUN, General, Cryo-3He, run 56 screenshots
|
|
Ongoing, e793s, Thu Mar 11 11:27:28 2021, Nicolas, Lynda, Charlie, RUN, General, CD2, run 56 screenshots
|
Scaler only |
Fixed, e793s, Thu Mar 11 12:39:01 2021, Nicolas, Lynda, Charlie, Sarah, RUN, General, CD2, run 56 screenshots 7x
|
|
Fixed, e793s, Thu Mar 11 10:25:30 2021, Nicolas, Lynda, Charlie, RUN, General, CD2, run 55 screenshots
|
Start of run, so scaler only - low stats in vigru plots |
Fixed, e793s, Thu Mar 11 01:24:47 2021, Ablaihan, Louis, RUN, General, CD2, run 53 screenshots 16x
|
Screenshots of the run 53
Beam intensity is ~ 7.4 10^5 pps in CATS and 5.3 10^5 in VAMOS
~75% transmition
|
Fixed, e793s, Thu Mar 11 05:12:36 2021, Ablaihan, Louis, RUN, General, CD2, run 53 new screenshots  
|
|
|