Fixed, e793s, Mon Mar 15 10:18:37 2021, Taras, cyril, Léo, ONLINE, Hardware, CD2, Cats2 tripped scalers10h18.png
Cats2 tripped with vamos, had to be reset
Beam is back
Fixed, e793s, Mon Mar 15 12:08:49 2021, Taras, cyril, Léo, ONLINE, Hardware, CD2, vamos dipole tripped at 12h05 
Vamos dipole tripped at around 12h05, had to be reset
Pending, e793s, Wed Mar 17 08:03:15 2021, Laetitia, Charlie, AGATA, Hardware, CD2, Agata issue 
There is a problem on Agata (the dewars are not being filled), and the Ge's start to warm up. The beam has been stopped at ~08h05.
Fixed, e793s, Wed Mar 17 09:53:38 2021, Cyril, AGATA, Hardware, CD2, Agata issue 
Agata problem has been solved, a valve was closed by mistake.
Beam returned at 9h40.
Fixed, TEST, Wed Jan 16 16:33:28 2019, Marlène, GRIT, General, 3-alpha, Status of detectors on 16/01/19 Detectors_status_160119.xlsxCapture_d’eÌcran_2019-01-16_aÌ€_17.05.57.png
MG1 has some issue with the HT cable (for the BT bias). There is a shortcut only under vacuum. We checked the connector but we have to do vacuum again to
check it.
Fixed, TEST, Wed Jan 16 17:36:30 2019, Valérian-Marlène, GRIT, General, N/A, Calimero tests - How to configure Calimero in GECO Calimero_MUVI1_MM2_voie3_allmates_bidim.pngCalimero_MUVI1_MM2_voie1_allmates_bidim.pngCalimero_MUVI1_MM3_voie1_allmates_bidim_withchannelsenabled.pngCalimero_MUVI1_MM3_voie3_allmates_bidim_withchannelsenabled.pngCalimero_MUVI1_MM2_allchannels_allmates_bidim_stat100000_withchannelsenabled.png
Tests of Calimero time calibration with MUVI1 channel 2 (MM2)

1- channel 3 of all mates selected (see screeshots)
Fixed, TEST, Fri Jan 18 15:32:50 2019, Adrien Valérian, GRIT, General, N/A, Calimero tests Muvi2 MM7 MG10C Calimero_MUVI2_MM7_allchannels_allmates__stat100000_withchannelsenabled.pngCalimero_MUVI2_MM7_allchannels_allmates_withchannelsenabled.png
After disabling nptool Multithreading, online is working fine again.

Concerning Calimero, it is currently working both on MUVI1 and MUVI2 for the X at least.
Fixed, , Tue Jan 22 11:15:15 2019, Marlène, GRIT, General, N/A, Square detectors MG9C_disabled_channels__no_crazy_ORD.pngMG9C_disabled_channels__no_crazy_ORD_moredetailed.pngMG9C_piedestal_of_disabled_channels_Y.png
MG9C (thin square detector coupled with thick square detector unplugged) noisy
On X channels --> no noise problem ( about 100 ORD in the dark)
On Y channels --> MATE 10 & 11 noisy ! (see picture below with noisy Y piedestals)
Ongoing, TEST, Tue Jan 22 18:52:23 2019, Valérian-Marlène, GRIT, General, 3-alpha, 3 alpha source run on MG10C & MG3T 
3 alpha source (not centered)
MG10C and MG3T ON
MG10C is connected to MG5T HT and BT and seen on MUVI1 channel2 -> online name=MM2
Fixed, TEST, Wed Jan 23 09:11:26 2019, Valérian-Marlène, GRIT, General, 3-alpha, RUN9 : 3 alpha source run on MG10C & MG3T 3alpha_sourceMG10C-MM2_MG3T-MM3.pngHV_squares_plugged_on_MG4T-MG5T_andMG3T.pngHV_squares_plugged_on_MG4T-MG5T_andMG3T_afternightrun.pngMG10C_7missingstrips.png
[B]RUN 9 (over night 22/01 ->23/01)[/B]
3 alpha source (not centered)
MG10C and MG3T ON
Fixed, , Wed Jan 23 12:24:10 2019, Marlène, GRIT, General, , Change cable MG1T - Exchange of detectors named MG9C & MG10C 
23/01/19

Change of the HT/BT cable of MG1T (the one that had a short cut before when the chamber was closed)
Fixed, , Fri Jan 25 17:02:25 2019, Marlène, GRIT, General, , Detectors numbering MUGAST_detectors.pdf
 
Fixed, TEST, Thu Feb 7 09:52:08 2019, Freddy, Marlène, RUN, General, 3-alpha, RUN10 : 3 alpha source on MG1-3-4-5-7 alpha_source_5trap_rawhistos_2.pngalpha_source_5trap_rawhistos.png
Test run with alpha source in front of trapezoid detectors.

First run with new LABELS updated from "MM" to "MG0" in GECO.
Fixed, , Thu Feb 14 08:50:58 2019, Marlene, GRIT, General, 3-alpha, RUN 27 8x
RUN 27 on 14th of feb.
3 alpha source (one in front of trap., one in front of square detectors)
Fixed, , Thu Feb 14 15:30:14 2019, Marlene Daniele Jenny, GRIT, General, 3-alpha, RUN 28 3alpha_sourceMG03XY._OKpng3alpha_sourceMG11XY.png3alpha_sourceMG01XY_OK.png
RUN 28 14th Feb
3 alpha source on MG11A, MG3T, MG1T
Fixed, , Fri Feb 15 15:31:28 2019, Marlène, GRIT, General, N/A, Detectors bias 
 
Fixed, com2019, Mon Feb 18 10:41:36 2019, Marlene, GRIT, General, N/A, Bias & current of detectors bias.png
 
Fixed, TEST, Thu Feb 21 09:08:49 2019, Freddy, RUN, General, 3-alpha, RUN 30 - alpha on MG 1,3,5,7  3alpha_source_MG_1357_20Feb.pngLowV_bis_run30.pngLowV_run30.pngHV_run30.png
[U][B]Run 30[/B][/U]

Alpha source run for trapezoid detectors during the night with pedestals aligned and zero suppression. Cooling at 15°C.
Fixed, TEST, Fri Mar 1 12:07:44 2019, Freddy, GRIT, General, 3-alpha, Efficiency reconstruction comparison.pdfcomparison.Calpha_eff.root
blue: reconstructed efficiency using alpha run 40 (arbitratily normalized)
red: simulated efficiency
Fixed, TEST, Mon Mar 4 12:28:26 2019, Valerian and Iulian, MUST2, General, 3-alpha, No DECS and acq error run 47-48-49. Das Saved after problem fixed run49_error_acq.png
Fixed. Solution:
1) CENTRUM not configured on GENTRUM Master
2) GMT matrix on GMT3 (2nd slave) was all 0