MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 56 of 132
Not logged in
Find
|
Login
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
55
, 56,
57
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
TEST
Fri Mar 6 07:48:47 2020
OttoH.V.
OTHER
Hardware
N/A
HVM_SUMMARY
[SIZE=5][COLOR=green][B]*** hvm watcher summary
***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green]+10V/t1234 [/COLOR]
Fixed
TEST
Mon Mar 9 15:10:40 2020
OttoH.V.
OTHER
Hardware
N/A
HVM_SUMMARY
[SIZE=5][COLOR=green][B]*** hvm watcher summary
***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green]+10v/mg [/COLOR]
Fixed
TEST
Mon Mar 9 15:10:41 2020
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
[SIZE=5][COLOR=red][B]*** hvm watcher error
***[/B] [/COLOR][/SIZE]
[SIZE=4][COLOR=green]-2.5v/mg11 [/COLOR]
Fixed
TEST
Mon Mar 9 15:10:42 2020
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
[SIZE=5][COLOR=red][B]*** hvm watcher error
***[/B] [/COLOR][/SIZE]
[SIZE=4][COLOR=green]+5V/t456 [/COLOR]
Fixed
TEST
Mon Mar 9 15:10:42 2020
OttoH.V.
OTHER
Hardware
N/A
HVM_SUMMARY
[SIZE=5][COLOR=green][B]*** hvm watcher summary
***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green]+10V/t1234 [/COLOR]
Fixed
TEST
Mon Mar 9 15:10:43 2020
OttoH.V.
OTHER
Hardware
N/A
HVM_SUMMARY
[SIZE=5][COLOR=green][B]*** hvm watcher summary
***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green] [/COLOR]
Fixed
TEST
Tue Mar 10 11:05:40 2020
Franco
GRIT
Hardware
3-alpha
Trip in the cooling system after e775s experiment
In the weekend after the experiment e775s
(7-8 March 2020) a problem with the cooling
system of Mugast occurred. In particular,
Fixed
e793s
Tue Mar 10 18:46:13 2020
Franco & Marlène
GRIT
Hardware
Changes in MUGAST
- MG6 (FZ) is disconnected.
- MG7 (500um) is dismounted and MG8 (375um)
is replacing it.
Fixed
TEST
Wed Mar 11 18:12:40 2020
Marlène & Franco
GRIT
Hardware
N/A
Update on Mugast
(Probably) final update of the status of the
detector before the experiment:
Fixed
TEST
Thu Mar 12 10:14:02 2020
Marlène & Franco
GRIT
Hardware
N/A
Debugging the cooling system
We realized that the increase of temperature
of MG7 and MG9 during run 600 (alpha calibration)
was due to the fact that a loop of the cooling
Fixed
TEST
Thu Mar 12 14:47:59 2020
Marlène & Franco
GRIT
Hardware
N/A
Moving MG9 square to MUVI2
- Since we are not using MG6 anymore (card
burnt), we replaced it with MG9 on slot 3
of MUVI2. MUVI4 is now unused. We changed
Fixed
TEST
Tue Feb 2 16:41:17 2021
Franco
VACUUM
Hardware
N/A
MUGAST undervacuum and powered up
I put back the supply of MM1 to the channel
1 of the MUST2 box (as in the normal configuration)
and polarized the detectors to make a rapid
Fixed
TEST
Thu Feb 4 18:16:47 2021
Franco
GRIT
Hardware
3-alpha
Problems with the annular persist
We opened the chamber to verify the connections
of the kaptons but they were all well connected.
We checked with the tester the conductivity
8x
Fixed
TEST
Fri Feb 5 12:44:42 2021
Franco
GRIT
Hardware
N/A
Pulser on MG11 MUFEE Y
I managed to obtain the spectrum with the
pulser on the annular (Y side, namely sectors).
The raw strip numbers where I should have
Fixed
e793s
Fri Feb 12 18:12:00 2021
Adrien
S1
Hardware
N/A
Kapton change
Arnaud open today and change the Y Kapton
(YA5) of the S1. Everything under vacuum/cooled
again so I ran FSC, hopefully this will fix
Ongoing
e793s
Wed Mar 3 17:12:57 2021
Franco
S1
Hardware
N/A
Schema of the new S1
The signals of the new S1 will be splitted
among 6 Mugast boards, according to the scheme
attached.
Fixed
TEST
Fri Mar 5 16:54:24 2021
OttoH.V.
OTHER
Hardware
N/A
HVM_SUMMARY
[SIZE=5][COLOR=green][B]*** hvm watcher summary
***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green]+10V/t1234 [/COLOR]
Fixed
TEST
Fri Mar 5 16:54:24 2021
OttoH.V.
OTHER
Hardware
N/A
HVM_SUMMARY
[SIZE=5][COLOR=green][B]*** hvm watcher summary
***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green]+10v/mg [/COLOR]
Fixed
TEST
Fri Mar 5 16:54:25 2021
OttoH.V.
OTHER
Hardware
N/A
HVM_SUMMARY
[SIZE=5][COLOR=green][B]*** hvm watcher summary
***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green] [/COLOR]
Fixed
e793s
Fri Mar 5 17:01:27 2021
mugast
S1
Hardware
N/A
Giving up on S1
We mounted the new S1 detector from Surrey
with a new custom cable on several MUFEE
cards using the CsI ASICs.
Goto page
Previous
1
,
2
,
3
...
55
, 56,
57
...
130
,
131
,
132
Next
ELOG Home Page