Fixed, e793s, Wed Mar 10 18:22:01 2021, Taras, Nishu, Chloe, RUN, General, , status screenshot
|
|
Fixed, e793s, Wed Mar 10 19:23:37 2021, mugast, OFFLINE, General, CD2, Kinematics and Ex - RUN051 
|
Preliminary analysis results, Backward angles.
MM5 position are incorrect |
Pending, e793s, Wed Mar 10 20:36:19 2021, Nigel, BEAM, General, CD2, Beam centering - MUST2 hit pattern
|
We made a quick check of the beam centering by inspecting the MUST2 (forward angles) hit pattern (plot attached). It appears that the beam is probably
somewhat off centre in the horizontal direction.
|
Fixed, e793s, Wed Mar 10 20:53:55 2021, OttoRun, RUN, General, CD2, Run52
|
*************************
[SIZE=3][B]Run : 52[/B][/SIZE]
*************************
|
Fixed, e793s, Wed Mar 10 21:02:03 2021, OttoRun, RUN, General, CD2, Run53
|
*************************
[SIZE=3][B]Run : 53[/B][/SIZE]
*************************
|
Ongoing, e793s, Wed Mar 10 21:09:25 2021, mugast (Adrien, Nigel et co), BEAM, General, , Primary beam issues
|
The secondary beam intensity has been fluctuating around 4 - 5 x 10**5 Hz most of the evening. 15 mins ago it was realised that it had dropped off to
only 1 x 10**5 Hz. As suspected, PCP confirmed that primary beam intensity has dropped off. They are investigating ...
|
Fixed, e793s, Wed Mar 10 22:19:22 2021, Adrien, Freddy, Wilton and Nigel, OFFLINE, General, CD2, Offline analysis of run 51 and 52 using ganil files
|
We noted that the gamma ray efficiency calculated from file converted from AGATA was close 100%. We concluded that the conversion program was reauiring
a gamma ray to be present.
|
Pending, e793s, Wed Mar 10 23:37:23 2021, Nishu, Chloe, Taras, RUN, General, , FAG value increased
|
Around 11:30 pm FAg value increased from usual 60-70 units to 140 units. It is suspected that MUGAST increased the trigger rate. |
Fixed, e793s, Thu Mar 11 01:24:47 2021, Ablaihan, Louis, RUN, General, CD2, run 53 screenshots 16x
|
Screenshots of the run 53
Beam intensity is ~ 7.4 10^5 pps in CATS and 5.3 10^5 in VAMOS
~75% transmition
|
Fixed, e793s, Thu Mar 11 02:50:14 2021, Ablaihan, Louis, BEAM, General, CD2, VAMOS transmition
|
at 2h50 beam intensity reached 1.1x10^6 pps in CATS for 6.5x10^5 pps in VAMOS. The transmition decreased to 60% without any shift of the beam position.
Does it come from a loss of efficiency of VAMOS at high counting rate? |
Fixed, e793s, Thu Mar 11 03:37:45 2021, Louis, OFFLINE, General, CD2, Offline analyis run 53    
|
1) Some angular distribution were extracted (without any efficiency corrections) with gate on Ex btw 0 and 2 MeV (where p orbitals are populated) and btw
2 and 4 MeV (where f orbitals are populated). More counts are observed btw 110 and 120 degrees in Lab angle with the 0-2MeV gate compared to the 2-4MeV
gate which is expected from the AWBA calculus. Kinematic cuts the large angles at high excitation energies. Geometrical efficiency is needed to compare |
Fixed, e793s, Thu Mar 11 04:34:58 2021, ablaihan, louis, CATS, Hardware, CD2, CATS and VAMOS tripped
|
at 4h15 CATS and VAMOS tripped probably due to too high beam intensity (~1.2x10^6 pps). We switched them on again at 4h30. All the 6 CATS in Board2 in HV
by 525 V instead of 530 V.
|
Fixed, e793s, Thu Mar 11 04:38:31 2021, Ablaihan, Louis, BEAM, General, CD2, Beam stopped due to a equipment tripped in CSS1
|
Beam stopped 4h30 due to a equipment tripped in CSS1. They are going to fix it. Estimated timing of the intervention ~10/20min.
Beam went back at 4h52 at 3.5x10^5 pps in CATS and 3.0x10^5 pps in VAMOS. transmision ~ 85% |
Fixed, e793s, Thu Mar 11 05:12:36 2021, Ablaihan, Louis, RUN, General, CD2, run 53 new screenshots  
|
|
Pending, e793s, Thu Mar 11 09:02:20 2021, mugast, BEAM, Hardware, CD2, beam interruption
|
power supply trip on the accelerator beam is off for about 30min |
Fixed, e793s, Thu Mar 11 09:04:38 2021, adrien, ONLINE, General, CD2, Elastic scattering in MM5
|
looking at E vs strip number in MM5 we see clearly the pp and dd elastic scattering. |
Fixed, e793s, Thu Mar 11 09:17:17 2021, Nicolas, Lynda, Charlie, RUN, General, CD2, run 53 new screenshots 7x
|
|
Fixed, e793s, Thu Mar 11 09:43:56 2021, OttoRun, RUN, General, CD2, Run54
|
*************************
[SIZE=3][B]Run : 54[/B][/SIZE]
*************************
|
Fixed, e793s, Thu Mar 11 10:18:48 2021, OttoRun, RUN, General, CD2, Run55
|
*************************
[SIZE=3][B]Run : 55[/B][/SIZE]
*************************
|
Fixed, e793s, Thu Mar 11 10:25:30 2021, Nicolas, Lynda, Charlie, RUN, General, CD2, run 55 screenshots
|
Start of run, so scaler only - low stats in vigru plots |
|