MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 48 of 132  Not logged in MUGAST
New entries since:Thu Jan 1 01:00:00 1970
Status ExpNbr Date Author Type Category Target-Sourcedown Subject
Fixede768s Mon Jul 15 20:07:48 2019 OttoRunRUNGeneralN/ARun11
*************************
Run : 11
*************************

Start at 2019-07-15 20:03:52.664898

fsc / calibT run

GMT: MUGAST (square detector not biased) + MUST2

Time calibrator:
range -> 640 ns
freq. -> 20 ns

Stop at 2019-07-15 20:09:19.003266
Stop comment: stop because too many overflow and too little statistics
Fixede744s Mon Jul 15 20:11:55 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI1
- Side : MUFEE X (Junction)
- Telescope: 1,
Fixede768s Mon Jul 15 20:12:30 2019 OttoRunRUNGeneralN/ARun12
*************************
Run : 12
*************************

Start at 2019-07-15 20:11:56.531359

fsc / calibT run

internal pulser frequency now set to 300 Hz (was about 1 kHz before)

GMT: MUGAST (square detector not biased) + MUST2

Time calibrator:
range -> 640 ns
freq. -> 20 ns

Stop at 2019-07-15 20:17:56.763955
Stop comment:
Fixede744s Mon Jul 15 20:17:58 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI1
- Side : MUFEE Y (Ohmic)
- Telescope: 1,
Fixede768s Mon Jul 15 20:18:07 2019 Marlène, Nicolas, SergeRUNGeneralN/ARun13 - fsc
*************************
Run : 13
*************************

Start at 2019-07-15 20:18:02.650063

fsc / calibT run

internal pulser frequency now set to 300 Hz (was about 1 kHz before)

GMT: MUGAST (square detector not biased) + MUST2

Time calibrator:
range -> 640 ns
freq. -> 20 ns

Stop at 2019-07-15 20:23:54.304478
Stop comment: type your message here
Fixede744s Mon Jul 15 20:23:56 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI2
- Side : MUFEE X (Junction)
- Telescope: 1,
Fixede768s Mon Jul 15 20:24:01 2019 OttoRunRUNGeneralN/ARun14
*************************
Run : 14
*************************

Start at 2019-07-15 20:23:58.790182

fsc / calibT run

internal pulser frequency now set to 300 Hz (was about 1 kHz before)

GMT: MUGAST (square detector not biased) + MUST2

Time calibrator:
range -> 640 ns
freq. -> 20 ns

Stop at 2019-07-15 20:30:02.695121
Stop comment:
Fixede744s Mon Jul 15 20:29:56 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI2
- Side : MUFEE Y (Ohmic)
- Telescope: 1,
Fixede768s Mon Jul 15 20:30:04 2019 OttoRunRUNGeneralN/ARun15
*************************
Run : 15
*************************

Start at 2019-07-15 20:29:59.325702

fsc / calibT run

internal pulser frequency now set to 300 Hz (was about 1 kHz before)

GMT: MUGAST (square detector not biased) + MUST2

Time calibrator:
range -> 640 ns
freq. -> 20 ns

Stop at 2019-07-15 20:35:53.451006
Stop comment: type your message here
Fixede744s Mon Jul 15 20:35:55 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 1,
Fixede768s Mon Jul 15 20:36:04 2019 OttoRunRUNGeneralN/ARun16
*************************
Run : 16
*************************

Start at 2019-07-15 20:36:00.148912

fsc / calibT run

internal pulser frequency now set to 300 Hz (was about 1 kHz before)

GMT: MUGAST (square detector not biased) + MUST2

Time calibrator:
range -> 640 ns
freq. -> 20 ns

Stop at 2019-07-15 20:41:36.377502
Stop comment:

Stop at 2019-07-15 20:41:59.835741
Stop comment: type your message here
Fixede744s Mon Jul 15 20:42:53 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI1
- Side : MUFEE X (Junction)
- Telescope: 1,
Fixede768s Mon Jul 15 20:43:18 2019 OttoRunRUNGeneralN/ARun17
*************************
Run : 17
*************************

Start at 2019-07-15 20:42:55.992890

fsc / calibT run

internal pulser frequency now set to 300 Hz (was about 1 kHz before)

GMT: MUGAST (square detector not biased) + MUST2

Time calibrator:
range -> 640 ns
freq. -> 20 ns

fsc modified to wait 60s instead of 10s

Stop at 2019-07-16 09:17:35.499644
Stop comment:

Stop at 2019-07-16 09:17:41.162065
Stop comment:
Fixede744s Mon Jul 15 21:02:19 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI1
- Side : MUFEE Y (Ohmic)
- Telescope: 1,
Fixede744s Mon Jul 15 21:21:40 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI2
- Side : MUFEE X (Junction)
- Telescope: 1,
Fixede744s Mon Jul 15 21:41:03 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI2
- Side : MUFEE Y (Ohmic)
- Telescope: 1,
Fixede744s Mon Jul 15 22:00:26 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 1,
Fixede744s Mon Jul 15 22:19:44 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 1,
Fixede744s Mon Jul 15 22:39:08 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI1
- Side : MUFEE X (Junction)
- Telescope: 2,
Fixede744s Mon Jul 15 22:58:29 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 144
- MUVI: MUVI1
- Side : MUFEE Y (Ohmic)
- Telescope: 2,

ELOG Home Page