Fixed, e744s, Wed Apr 10 11:46:04 2019, iulian, BEAM, Social, N/A, E744 Status
|
Refrigeration problem, beam stopped.
Optimistic estimation: they need 1 UT to setup CIME => 14N could be back around 20h.
Optimistic scenario still on track
Then need 2 UT's to set CSS1 -> 14O next day around 18h
No shifts until 24h00 (midnight) today.
Shift to resume 11/04 @00h00
18h30 14N beam is back. |
Pinned, e744s, Wed Apr 10 11:57:37 2019, A. Lemasson, OFFLINE, Software, , VAMOS Conversion HowTo
|
HOW TO convert a run in VAMOS
- Do : source $HOME/GoToVamosAna
- To Convert a Run : MyVAna -d2Ar <RunNr>
- Otherwise, If you want to convert a single file : MyVAna -d2Ar -f <Infile> <OutFile>
- Output Root rile is written to : ./RootA/
If you encounter the error on Brho "Could not find the BrhoRef for the run <RunNr> ", Update the ./Calibs/ListBrho.dat file with relevant Brho for RunNr |
Fixed, e744s, Wed Apr 10 19:54:11 2019, OttoRun, RUN, General, N/A, Run40
|
*************************
Run : 40
*************************
Start at 2019-04-10 19:42:37.772698
Run Conditions:
- Operator: A. Lemasson
- Trigger:
- Target/Source: none
- Beam: VAMOS Closed
- Intensity:
Comment:
Test ACQ AGATA
Stop at 2019-04-10 19:54:12.687611
Stop comment: |
Fixed, e744s, Wed Apr 10 20:13:07 2019, OttoRun, RUN, General, N/A, Run50 
|
*************************
Run : 50
*************************
Start at 2019-04-10 20:11:52.495577
Run Conditions:
- Operator: A. Lemasson Iulian
- Trigger: VAMOS
- Target/Source: Hole 7mm
- Beam: 14N
- Intensity: 1e3
- Brho = 0.79067 Tm
Comment:
First Run 14N
|
Fixed, e744s, Wed Apr 10 20:16:22 2019, Iulian, BEAM, General, N/A, 14N beam characteristics and Brho vamos setting   
|
Also the beam profile on gas profiler before and after inserting a peperpot |
Fixed, e744s, Wed Apr 10 21:16:20 2019, OttoRun, RUN, General, N/A, Run51
|
*************************
Run : 51
*************************
Start at 2019-04-10 21:16:08.923139
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: Hole 7mm
- Beam: 14N
- Intensity: ~ 1e3
- Brho = 0.79067 Tm
Comment:
First Run 14N
|
Fixed, e744s, Wed Apr 10 21:31:31 2019, OttoRun, RUN, General, N/A, Run52 
|
*************************
Run : 52
*************************
Start at 2019-04-10 21:31:26.692634
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: Hole 7mm
- Beam: 14N
- Intensity: ~ 1e3
- Brho = 0.79067 Tm
Comment:
First Run 14N
Stop at 2019-04-10 22:14:35.626012
Stop comment:
Optimisation beam position
|
Fixed, e744s, Wed Apr 10 22:15:30 2019, OttoRun, RUN, General, N/A, Run53
|
*************************
Run : 53
*************************
Start at 2019-04-10 22:14:38.456261
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: Hole 7mm
- Beam: 14N
- Intensity: ~ 1e3
- Brho = 0.79067 Tm
Comment:
Reference Run With target Hole
C6 E5-H0 -1.5
C6 E3-VE 0.5
Stop at 2019-04-10 22:39:54.849769
Stop comment: |
Fixed, e744s, Wed Apr 10 22:40:12 2019, OttoRun, RUN, General, N/A, Run54
|
*************************
Run : 54
*************************
Start at 2019-04-10 22:40:01.150255
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: Hole 7mm
- Beam: 14N
- Intensity: ~ 1e3
- Brho = 0.79067 Tm
Comment:
Reference Run With target Hole and IC OK
C6 E5-H0 -1.5
C6 E3-VE 0.5
Stop at 2019-04-10 22:59:42.204273
Stop comment: |
Fixed, e744s, Wed Apr 10 23:00:27 2019, OttoRun, RUN, General, N/A, Run55
|
*************************
Run : 55
*************************
Start at 2019-04-10 23:00:06.487980
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: Hole 7mm
- Beam: 14N
- Intensity: ~ 1e3
- Brho = 0.79067 Tm
Comment:
Reference Run With target Hole and IC OK PPAC voltages were too low in MW08
C6 E5-H0 -1.5
C6 E3-VE 0.5
Stop at 2019-04-10 23:08:11.925795
Stop comment: |
Fixed, e744s, Wed Apr 10 23:31:05 2019, OttoRun, RUN, General, N/A, Run56
|
*************************
Run : 56
*************************
Start at 2019-04-10 23:30:06.453554
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: No Target
- Beam: 14N
- Intensity: ~ 1e3
- Brho = 0.79067 Tm
- CATS 2 IN
Comment:
Reference Run With target Hole and IC OK PPAC voltages were too low in MW08
C6 E5-H0 -1.5
C6 E3-VE 0.5
Stop at 2019-04-10 23:55:46.381062
Stop comment: |
Fixed, e744s, Wed Apr 10 23:56:35 2019, OttoRun, RUN, General, N/A, Run57
|
*************************
Run : 57
*************************
Start at 2019-04-10 23:56:04.653778
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: No Target
- Beam: 14N
- Intensity: ~ 1e3
- Brho = 0.79067 Tm
- CATS 2 IN
Comment:
Reference Run Without target and IC OK PPAC voltages were too low in MW08
C6 E5-H0 -1.5
C6 E3-VE 0.5
After Setting IC Threshold
Stop at 2019-04-11 00:00:51.262090
Stop comment: |
Fixed, e744s, Thu Apr 11 00:03:37 2019, OttoRun, RUN, General, N/A, Run58
|
========================================
*************************
Run : 58
*************************
Start at 2019-04-11 00:03:18.437004
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: No Target
- Beam: 14N
- Intensity: ~ 1e3
- Brho = 0.79067 Tm
- CATS 2 IN
Comment:
Reference Run Without target and IC OK PPAC voltages were too low in MW08
C6 E5-H0 -1.5
C6 E3-VE 0.5
After Setting IC Threshold
Placing Finger on The beam
Stop at 2019-04-11 00:16:46.322754
Stop comment:
run58_Brho_Cats2_14N.png -> Brho no target Cats2 |
Fixed, e744s, Thu Apr 11 00:06:50 2019, A. Lemasson, RUN, General, N/A, Run58 
|
Without Finger 21 kHz -> Reduced to 800 Hz with finger |
Fixed, e744s, Thu Apr 11 00:23:21 2019, Iulian François Marlène, RUN, Hardware, CH2, TAC changes & target
|
We have inserted the 2nd target CH2 104 um.
We have changed the range of the TAC MUGAST-HF from 1us to 200ns.
TAC VAMOS-CATS1 (in fact CATS2) was not working in the previous run because there was no delay on CATS. We send now CATS DELAY x2, meaning that the delay is 300ns. |
Fixed, e744s, Thu Apr 11 00:28:44 2019, OttoRun, RUN, General, CH2, Run59
|
*************************
Run : 59
*************************
Start at 2019-04-11 00:27:28.387554
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: CH2 100 um (Position 2)
- Beam: 14N
- Intensity: ~ 2e+4
- Brho = 0.79067 Tm
- CATS 2 IN
Comment:
Target inserted (100 um ) and Cats2 in
Placing Finger on The beam
Stop at 2019-04-11 00:49:00.966603
Stop comment: |
Fixed, e744s, Thu Apr 11 00:57:34 2019, iulian, OTHER, Hardware, CH2, CH2 target thickness
|
target CH2 104 um (2nd position)
Brho 14N6+ CATS2 |
Fixed, e744s, Thu Apr 11 01:00:46 2019, OttoRun, RUN, General, CH2, Run60
|
*************************
Run : 60
*************************
Start at 2019-04-11 00:59:35.983897
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: CH2 100 um (Position 3)
- Beam: 14N
- Intensity: ~ 2e+4
- Brho = 0.79067 Tm
- CATS 2 IN
Comment:
Target inserted (100 um ) and Cats2 in
Placing Finger on The beam
Vamos IC10 placed in IC12 electronics
|
Fixed, e744s, Thu Apr 11 01:05:35 2019, OttoRun, RUN, General, CH2, Run61
|
*************************
Run : 61
*************************
Start at 2019-04-11 01:04:59.561319
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: CH2 100 um (Position 3)
- Beam: 14N
- Intensity: ~ 2e+4
- Brho = 0.79067 Tm
- CATS 2 IN
Comment:
Same as run 60 after DAQ NARVAL crash. (broken link 102 ???)
Target inserted (100 um ) and Cats2 in
Placing Finger on The beam
Vamos IC10 placed in IC12 electronics
|
Fixed, e744s, Thu Apr 11 01:09:05 2019, OttoRun, RUN, General, CH2, Run62
|
*************************
Run : 62
*************************
Start at 2019-04-11 01:08:38.422386
Run Conditions:
- Operator: A. Lemasson
- Trigger: VAMOS
- Target/Source: CH2 100 um (Position 3)
- Beam: 14N
- Intensity: ~ 2e+4
- Brho = 0.79067 Tm
- CATS 2 IN
Comment:
Same as run 60 after DAQ NARVAL crash. (DC not sending Data, Kill Narval on ganp507 and vamosng)
Target inserted (100 um ) and Cats2 in
Placing Finger on The beam
Vamos IC10 placed in IC12 electronics
|
|