Fixed, e744s, Tue Apr 9 17:29:42 2019, OttoRun, RUN, General, N/A, Run15
|
*************************
Run : 15
*************************
Start at 2019-04-09 17:28:36.891546
Run Conditions:
- Operator: Marlene Francois Iulian
- Trigger: Agata 42
- Target/Source: none
- Beam: no
- Intensity:
Comment: test E_Agata T_Agata_HF
Stop at 2019-04-09 17:38:19.254981
Stop comment: type your message here |
Fixed, e744s, Tue Apr 9 17:38:57 2019, OttoRun, RUN, General, N/A, Run16
|
*************************
Run : 16
*************************
Start at 2019-04-09 17:38:26.658961
Run Conditions:
- Operator: Marlene Francois Iulian
- Trigger: Agata 42
- Target/Source: none
- Beam: no
- Intensity:
Comment: test E_Agata T_Agata_HF
change gain in E_AGATA & T_Agata_HF
Stop at 2019-04-09 17:45:38.676271
Stop comment:
Stop at 2019-04-09 18:52:35.491887
Stop comment: type your message here
Stop at 2019-04-09 21:45:52.997597
Stop comment: |
Fixed, e744s, Tue Apr 9 18:08:22 2019, Marlène and François, DAQ, Software, , new inputs in the ADC Mugast
|
new inputs in the ADC mugast
T_Mugast_HF = input N°2
E_AGATA = agata 42 = input N°3
T_AGATA_HF = N° 4
gains of the signal AGATA 42 were changed from 200 to 50
|
Fixed, e744s, Tue Apr 9 18:29:04 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 17
- MUVI: MUVI1
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4 |
Fixed, e744s, Tue Apr 9 18:52:49 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 18
- MUVI: MUVI1
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4 |
Fixed, e744s, Tue Apr 9 19:19:37 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 19
- MUVI: MUVI2
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4 |
Fixed, e744s, Tue Apr 9 19:43:25 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 20
- MUVI: MUVI2
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4 |
Fixed, e744s, Tue Apr 9 20:07:12 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 21
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4 |
Fixed, e744s, Tue Apr 9 20:30:56 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 22
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4 |
Fixed, e744s, Wed Apr 10 06:45:53 2019, François, BEAM, Social, , No beam yet
|
They are about to align the beam from the cyclotron CIME to the area G1. |
Fixed, e744s, Wed Apr 10 06:51:35 2019, Beyhan, BEAM, General, , 14N7+ beam characteristics and settings at VAMOS   
|
|
Fixed, e744s, Wed Apr 10 07:15:22 2019, François, BEAM, Social, , no beam
|
They aligned the beam up to G1 Pr31 but the stripper foil was not inserted, so they have to start the work again. |
Fixed, e744s, Wed Apr 10 09:05:33 2019, François, BEAM, Social, , No beam in G1 yet.
|
The beam is at the entrance of G1. |
Fixed, e744s, Wed Apr 10 09:06:16 2019, Adrien, OFFLINE, General, N/A, Strange size of Time Calibrator Run
|
The two run for MUVI 1 are larger than the run for MUVI2 and 3.
I think this is due to the noise on MG4 that create a lot of Data but it need to be investigated.
The run are now converted to root using offline.
-r--r--r-- 1 mugast Exxx 2,0G 9 avril 18:52 run_0017.dat.09-04-19_18h29m04s
-r--r--r-- 1 mugast Exxx 2,4G 9 avril 19:19 run_0018.dat.09-04-19_18h52m49s
-r--r--r-- 1 mugast Exxx 84M 9 avril 19:42 run_0019.dat.09-04-19_19h19m37s
-r--r--r-- 1 mugast Exxx 170M 9 avril 20:06 run_0020.dat.09-04-19_19h43m25s
-r--r--r-- 1 mugast Exxx 213M 9 avril 20:29 run_0021.dat.09-04-19_20h07m12s
-r--r--r-- 1 mugast Exxx 269M 9 avril 20:53 run_0022.dat.09-04-19_20h30m56s |
Fixed, e744s, Wed Apr 10 09:12:32 2019, Adrien, OTHER, General, N/A, Folder for conversion
|
I setup the various folder for conversion in : /data/mugastX/e744/acquisition/
- run : MFM run from GANIL daq (VAMOS+MUGAST)
- MERGED_DATA : root run after merged from Agata
- root_np : raw data converted using ganil2root Offline (MUGAST raw only)
- np_output: tree analysed using nptool.
|
Fixed, e744s, Wed Apr 10 09:51:36 2019, OttoRun, RUN, General, N/A, Run24
|
*************************
Run : 24
*************************
Start at 2019-04-10 09:50:23.123384
Run Conditions:
- Operator: A. Lemasson
- Trigger: Vamos Pb with DC 63
- Target/Source: none
- Beam: VAMOS Closed
- Intensity:
Comment:
Test ACQ
Stop at 2019-04-10 10:10:11.417806
Stop comment: |
Fixed, e744s, Wed Apr 10 10:15:38 2019, François, BEAM, Social, , Beam stopped
|
A problem with the cooling water.
2 UT at least to restart the accelerator |
Fixed, e744s, Wed Apr 10 10:32:13 2019, OttoRun, RUN, General, N/A, Run25
|
*************************
Run : 25
*************************
Start at 2019-04-10 10:32:09.081219
Run Conditions:
- Operator: A. Lemasson
- Trigger: Vamos Pb with DC 63
- Target/Source: none
- Beam: VAMOS Closed
- Intensity:
Comment:
Test ACQ
Stop at 2019-04-10 10:34:30.735079
Stop comment: |
Fixed, e744s, Wed Apr 10 10:36:48 2019, OttoRun, RUN, General, N/A, Run26
|
*************************
Run : 26
*************************
Start at 2019-04-10 10:36:46.761926
Run Conditions:
- Operator: A. Lemasson
- Trigger: Vamos Pb with DC 63
- Target/Source: none
- Beam: VAMOS Closed
- Intensity:
Comment:
Test ACQ
Stop at 2019-04-10 10:46:01.017415
Stop comment: |
Fixed, e744s, Wed Apr 10 11:24:52 2019, Louis, OFFLINE, General, N/A, Time calibration for e744
|
Time calibration has been done for Mugast and MUST2 using run 17 to 22.
Calibration file are in:
/home/mugast/analysis/nptool/Projects/calibration/Time/Coeff/e744
Plot of calibration run after calibration are shown for MUST2 |
|