Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e768s |
Fri Jul 12 16:35:10 2019 |
OttoRun | RUN | General | 3-alpha | Run303 |
*************************
Run : 303
*************************
Start at 2019-07-12 16:35:04.481793
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X &Y strips masked;
+ MG9 removed
Stop at 2019-07-12 16:38:40.222071
Stop comment: type your message here |
Fixed | e768s |
Fri Jul 12 16:42:22 2019 |
OttoRun | RUN | General | 3-alpha | Run303 |
JUNK
*************************
Run : 303
*************************
Start at 2019-07-12 16:41:50.518089
3 alpha calibration run
+ MM2 masks
+ suppressed pedestals (new pedestal for all trap detectors)
Square detectors:
+ MG10: not biased
+ MG9 removed
Stop at 2019-07-12 16:43:54.495178
Stop comment: type your message here |
Fixed | e768s |
Thu Jul 11 16:54:34 2019 |
OttoRun | RUN | General | 3-alpha | Run302 |
*************************
Run : 302
*************************
Start at 2019-07-11 16:54:22.512184
3 alpha calibration run
+ without MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-12 05:44:35.805449
Stop comment: |
Fixed | e768s |
Mon Jul 15 14:38:27 2019 |
Franco | RUN | General | 3-alpha | Run302 |
Attached the calibrated spectra for MUST2 and Mugast for run 302 (no pedestals).
OttoRun wrote: | *************************
Run : 302
*************************
Start at 2019-07-11 16:54:22.512184
3 alpha calibration run
+ without MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-12 05:44:35.805449
Stop comment: |
|
Attachment 1: run0302_must2_cal.png
|
|
Attachment 2: run0302_mugast_cal.png
|
|
Fixed | e768s |
Fri Jul 19 23:10:18 2019 |
Franco | RUN | General | 3-alpha | Run302 |
Added energy calibration for square detector (MG 10).
OttoRun wrote: | *************************
Run : 302
*************************
Start at 2019-07-11 16:54:22.512184
3 alpha calibration run
+ without MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-12 05:44:35.805449
Stop comment: |
|
Attachment 1: run302_MG_Ecal.png
|
|
Fixed | e768s |
Fri Jul 19 23:12:36 2019 |
Franco | RUN | General | 3-alpha | Run302 |
Added energy calibration for square detector (MG 10).
Franco wrote: | Attached the calibrated spectra for MUST2 and Mugast for run 302 (no pedestals).
OttoRun wrote: | *************************
Run : 302
*************************
Start at 2019-07-11 16:54:22.512184
3 alpha calibration run
+ without MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-12 05:44:35.805449
Stop comment: |
|
|
Attachment 1: run302_MG_Ecal.png
|
|
Fixed | e768s |
Thu Jul 11 15:12:21 2019 |
OttoRun | RUN | General | 3-alpha | Run301 |
*************************
Run : 301
*************************
Start at 2019-07-11 15:07:27.670320
3 alpha calibration run
+ without MM2 masks
+ non suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-11 16:52:55.206383
Stop comment: stopping run to put pedestal suppression |
Fixed | e768s |
Mon Jul 15 18:28:19 2019 |
Franco | RUN | General | 3-alpha | Run301 |
Attached the calibrated spectra for MUST2 and Mugast for run 301.
OttoRun wrote: | *************************
Run : 301
*************************
Start at 2019-07-11 15:07:27.670320
3 alpha calibration run
+ without MM2 masks
+ non suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-11 16:52:55.206383
Stop comment: stopping run to put pedestal suppression |
|
Attachment 1: run0301_must2_cal.png
|
|
Attachment 2: run0301_mugast_cal.png
|
|
Fixed | e768s |
Tue Jul 16 09:51:56 2019 |
Franco | RUN | General | 3-alpha | Run301 |
Attached the dat file with the position of the pedestals for each strip of MG3_X
that can be used to correct the pedestal problem of MG3_X in later runs (from run O306).
Franco wrote: | Attached the calibrated spectra for MUST2 and Mugast for run 301.
OttoRun wrote: | *************************
Run : 301
*************************
Start at 2019-07-11 15:07:27.670320
3 alpha calibration run
+ without MM2 masks
+ non suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-11 16:52:55.206383
Stop comment: stopping run to put pedestal suppression |
|
|
Attachment 1: pedestals_MG3_STRX_E_RAW.dat
|
#Strip Pedestal pos.
1 8192.3
2 8192.04
3 8192.01
4 8192.3
5 8192.07
6 8192.05
7 8192.53
8 8191.71
9 8191.33
10 8190.86
11 8190.64
12 8190.34
13 8189.44
14 8188.99
15 8437.76
16 8437.76
17 8192.91
18 8192.76
19 8192.5
20 8192.05
21 8192.05
22 8192.04
23 8191.66
24 8191.9
25 8191.88
26 8191.93
27 8191.77
28 8191.15
29 8191.19
30 8191.39
31 8191.63
32 8192.03
33 8192.28
34 8192.46
35 8191.93
36 8191.42
37 8192.15
38 8192.55
39 8192.74
40 8192.58
41 8192.57
42 8193.06
43 8192.91
44 8192.55
45 8192.46
46 8192.66
47 8192.61
48 8192.83
49 8192.98
50 8192.61
51 8192.45
52 8192.87
53 8192.83
54 8192.57
55 8192.57
56 8192.46
57 8192.59
58 8192.48
59 8192.53
60 8192.54
61 8192.65
62 8192.68
63 8192.57
64 8192.7
65 8191.82
66 8190.82
67 8191.16
68 8191.34
69 8191.22
70 8191.68
71 8191.89
72 8191.74
73 8191.69
74 8192.04
75 8191.72
76 8191.75
77 8191.83
78 8192
79 8191.93
80 8191.85
81 8192.37
82 8192.54
83 8192.52
84 8192.29
85 8192.19
86 8191.81
87 8192.06
88 8192.51
89 8192.55
90 8192.27
91 8192.24
92 8192.35
93 8192.07
94 8192.51
95 8191.28
96 8190.31
97 8191.3
98 8191.94
99 8192.28
100 8192.65
101 8192.4
102 8191.86
103 8191.55
104 8191.57
105 8191.67
106 8191.76
107 8191.97
108 8191.58
109 8191.6
110 8191.96
111 8191.77
112 8191.89
113 8192.44
114 8192.58
115 8192.51
116 8192.37
117 8192.06
118 8191.6
119 8191.88
120 8191.7
121 8191.5
122 8191.73
123 8191.6
124 8191.4
125 8191.67
126 8191.94
127 8191.52
128 8191.83
|
Fixed | e768s |
Tue Jul 16 09:17:48 2019 |
OttoRun | RUN | General | N/A | Run30 |
*************************
Run : 30
*************************
Start at 2019-07-16 00:54:27.174959
fsc / calibT run
internal pulser frequency now set to 300 Hz (was about 1 kHz before)
GMT: MUGAST (square detector not biased) + MUST2
Time calibrator:
range -> 640 ns
freq. -> 20 ns
fsc modified to wait 60s instead of 10s |
Fixed | e768s |
Tue Jul 16 09:18:07 2019 |
OttoRun | RUN | General | N/A | Run29 |
*************************
Run : 29
*************************
Start at 2019-07-16 00:35:09.645821
fsc / calibT run
internal pulser frequency now set to 300 Hz (was about 1 kHz before)
GMT: MUGAST (square detector not biased) + MUST2
Time calibrator:
range -> 640 ns
freq. -> 20 ns
fsc modified to wait 60s instead of 10s |
Fixed | e786s |
Sun Jun 23 18:09:17 2019 |
OttoRun | RUN | General | Cryo-empty | Run28 |
*************************
Run : 28
*************************
Start at 2019-06-23 18:09:16.019140
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
TRIGGER
VAMOS %1000
MUGAST
MUS2
Stop at 2019-06-23 18:15:20.785307
Stop comment: |
Fixed | e768s |
Tue Jul 16 09:17:49 2019 |
OttoRun | RUN | General | N/A | Run28 |
*************************
Run : 28
*************************
Start at 2019-07-16 00:15:50.617493
fsc / calibT run
internal pulser frequency now set to 300 Hz (was about 1 kHz before)
GMT: MUGAST (square detector not biased) + MUST2
Time calibrator:
range -> 640 ns
freq. -> 20 ns
fsc modified to wait 60s instead of 10s
Stop at 2019-07-16 09:17:51.288072
Stop comment:
Stop at 2019-07-16 09:17:51.824283
Stop comment:
Stop at 2019-07-16 09:17:52.302740
Stop comment:
Stop at 2019-07-16 09:17:52.781598
Stop comment: |
Fixed | e768s |
Tue Jul 16 09:18:09 2019 |
OttoRun | RUN | General | N/A | Run27 |
*************************
Run : 27
*************************
Start at 2019-07-15 23:56:24.751783
fsc / calibT run
internal pulser frequency now set to 300 Hz (was about 1 kHz before)
GMT: MUGAST (square detector not biased) + MUST2
Time calibrator:
range -> 640 ns
freq. -> 20 ns
fsc modified to wait 60s instead of 10s |
Fixed | com2019 |
Sun Apr 7 21:45:35 2019 |
OttoRun | RUN | General | CD2 | Run262 |
*************************
Run : 262
*************************
Start at 2019-04-07 21:45:06.409673
Run Conditions:
- Operator: Iulian Marlene
- Trigger: MUST2 + MG BWd + VAMOS % 100
- Target/Source: CD2 1mg
- Beam: no
- Intensity:
Comment: Target holder removed
background check
Stop at 2019-04-08 07:38:35.058779
Stop comment:
end run
Alfa background is continuous in energy particularly in the backward detectors
|
Attachment 1: bilan_run262_bck_mugast4.png
|
|
Attachment 2: bilan_run262_bck_mugast3.png
|
|
Attachment 3: bilan_run262_bck_mugast2.png
|
|
Attachment 4: bilan_run262_bck_mugast1.png
|
|
Fixed | com2019 |
Sun Apr 7 21:43:29 2019 |
OttoRun | RUN | General | CD2 | Run261 |
*************************
Run : 261
*************************
Start at 2019-04-07 21:43:00.572161
Run Conditions:
- Operator: Iulian Marlene
- Trigger: MUST2 + MG BWd + VAMOS % 100
- Target/Source: CD2 1mg
- Beam: no
- Intensity:
Comment: Target holder in position
junk
Stop at 2019-04-07 21:44:59.581974
Stop comment: junk |
Fixed | e744s |
Wed Apr 10 10:36:48 2019 |
OttoRun | RUN | General | N/A | Run26 |
*************************
Run : 26
*************************
Start at 2019-04-10 10:36:46.761926
Run Conditions:
- Operator: A. Lemasson
- Trigger: Vamos Pb with DC 63
- Target/Source: none
- Beam: VAMOS Closed
- Intensity:
Comment:
Test ACQ
Stop at 2019-04-10 10:46:01.017415
Stop comment: |
Fixed | e786s |
Sun Jun 23 17:44:22 2019 |
OttoRun | RUN | General | Cryo-empty | Run26 |
*************************
Run : 26
*************************
Start at 2019-06-23 17:44:18.480300
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
TRIGGER
VAMOS %1000
MUGAST
MUS2
Stop at 2019-06-23 18:03:57.967230
Stop comment:
Stop at 2019-06-23 18:08:11.630931
Stop comment: |
Fixed | e768s |
Tue Jul 16 09:32:10 2019 |
OttoRun | RUN | General | N/A | Run26 |
*************************
Run : 26
*************************
Start at 2019-07-15 23:37:09.715822
fsc / calibT run
internal pulser frequency now set to 300 Hz (was about 1 kHz before)
GMT: MUGAST (square detector not biased) + MUST2
Time calibrator:
range -> 640 ns
freq. -> 20 ns
fsc modified to wait 60s instead of 10s |
Fixed | com2019 |
Sat Apr 6 18:32:26 2019 |
OttoRun | RUN | General | CD2 | Run259 |
*************************
Run : 259
*************************
Start at 2019-04-06 18:31:46.303930
Run Conditions:
- Operator:
- Trigger: MUST2 + MG BWd + VAMOS % 100
- Target/Source: CD2 1mg
- Beam: no
- Intensity:
Comment: Target holder in position
|