MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 34 of 132  Not logged in MUGAST
New entries since:Thu Jan 1 01:00:00 1970
Status ExpNbr Date Author Type Category Target-Source Subjectdown
Fixede786s Sat Jun 29 05:56:40 2019 OttoRunRUNGeneralCryo-3HeRun77

OttoRun wrote:

OttoRun wrote:

OttoRun wrote:
*************************
Run : 77
*************************

Start at 2019-06-28 18:34:22.873862

target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

AGATA position +51-25 mm

TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000

all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise

beam back. Q pole issues still

Beam is back, again, at 1.53, weird behavior of CATS


After beam is back we found 350Hz on vamos focal plane, with 20kHz current. After Brho scanning we found a Brho distribution going from 1Tm to 0.4Tm. Observation of gamma rays indicates no accumulation of radioactivity in the chamber with respect to previous runs. We conclude that we may have ice layers up to 500um in the target but very in-homogeneous since we also observe 1Tm Brho. To verify maybe increase target pressure to modify the structure of the ice. CATS is tripping continuously. No VACUUM changes observed.
Fixede768s Thu Jul 18 00:16:56 2019 OttoRunRUNGeneralN/ARun77
*************************
Run : 77
*************************

Start at 2019-07-18 00:11:48.462091

Time calibrator starting from MG3
strip by strip

Range 640 ns
Period 160 ns
Fixede744s Thu Apr 11 08:01:12 2019 OttoRunRUNGeneralCH2Run76
*************************
Run : 76
*************************

Start at 2019-04-11 07:59:50.438662

Run Conditions:
  • Operator: Nikola, Marion
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN


Comment: Beam stopped (Balise).

Stop at 2019-04-11 08:33:56.045621
Stop comment:
Fixede786s Fri Jun 28 15:25:12 2019 OttoRunRUNGeneralCryo-3HeRun76
*************************
Run : 76
*************************

Start at 2019-06-28 15:24:51.867946

target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

AGATA position +51-25 mm

TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000

all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise

beam back. Q pole issues still

Stop at 2019-06-28 16:55:27.258794
Stop comment:
Fixede768s Thu Jul 18 00:16:52 2019 OttoRunRUNGeneralN/ARun76
*************************
Run : 76
*************************

Start at 2019-07-17 23:09:25.888318

Time calibrator starting from MG3
strip by strip

Range 640 ns
Period 160 ns
Fixede744s Thu Apr 11 06:41:14 2019 OttoRunRUNGeneralCH2Run75
========================================
*************************
Run : 75
*************************

Start at 2019-04-11 06:40:54.479084

Run Conditions:
  • Operator: A. Lemasson
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN


Comment:

Stop at 2019-04-11 07:29:11.245553
Stop comment:
Fixede744s Thu Apr 11 07:17:33 2019 OttoRunRUNGeneralCH2Run75

OttoRun wrote:
*************************
Run : 75
*************************

Start at 2019-04-11 06:40:54.479084

Run Conditions:
  • Operator: A. Lemasson
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN


Comment:
Attachment 1: run75_1.png
run75_1.png
Attachment 2: run75_2.png
run75_2.png
Attachment 3: run75_3.png
run75_3.png
Attachment 4: run75_4.png
run75_4.png
Attachment 5: run75_5.png
run75_5.png
Attachment 6: run75_6.png
run75_6.png
Attachment 7: run75_7.png
run75_7.png
Attachment 8: run75_8.png
run75_8.png
Attachment 9: run75_9.png
run75_9.png
Attachment 10: run75_10.png
run75_10.png
Attachment 11: run75_11.png
run75_11.png
Attachment 12: run75_scaler.png
run75_scaler.png
Fixede786s Fri Jun 28 10:00:25 2019 OttoRunRUNGeneralCryo-3HeRun75
*************************
Run : 75
*************************

Start at 2019-06-28 09:59:59.505010

target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

AGATA position +51-25 mm

TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000

all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise

CATS threshold raised

Stop at 2019-06-28 14:33:09.843668
Stop comment:
Fixede768s Thu Jul 18 00:16:58 2019 OttoRunRUNGeneralN/ARun75
*************************
Run : 75
*************************

Start at 2019-07-17 22:06:59.976407

Time calibrator starting from MG3
strip by strip

Range 640 ns
Period 160 ns

Stop at 2019-07-18 00:16:59.664044
Stop comment:

Stop at 2019-07-18 00:17:01.189328
Stop comment:

Stop at 2019-07-18 10:44:37.670485
Stop comment:
Fixede744s Thu Apr 11 04:39:48 2019 OttoRunRUNGeneralCH2Run74
*************************
Run : 74
*************************

Start at 2019-04-11 04:37:42.487024

Run Conditions:
  • Operator: AIulian Marlene Diego
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN

First good data run. 2.7e+5 counts Cats2
Comment:

Stop at 2019-04-11 06:23:39.836186
Stop comment: good run
Fixede786s Thu Jun 27 23:28:30 2019 OttoRunRUNGeneralCryo-3HeRun74
*************************
Run : 74
*************************

Start at 2019-06-27 23:25:00.455575

target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

AGATA position +51-25 mm

TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000

all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise

Stop at 2019-06-28 09:31:40.775271
Stop comment:
Fixede768s Thu Jul 18 00:16:53 2019 OttoRunRUNGeneralN/ARun74
*************************
Run : 74
*************************

Start at 2019-07-17 21:03:59.134373

Time calibrator starting from MG3
strip by strip

Range 640 ns
Period 160 ns

Stop at 2019-07-18 00:16:55.063278
Stop comment:
Fixede744s Thu Apr 11 03:40:44 2019 OttoRunRUNGeneralCH2Run73
*************************
Run : 73
*************************

Start at 2019-04-11 03:39:15.971913

Run Conditions:
  • Operator: A. Lemasson
  • Trigger: VAMOS
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+4
  • Brho = 0.437 Tm
  • CATS 2 IN


Comment:

Stop at 2019-04-11 04:25:03.931527
Stop comment:
Fixede786s Thu Jun 27 20:26:27 2019 OttoRunRUNGeneralCryo-3HeRun73
*************************
Run : 73
*************************

Start at 2019-06-27 20:26:17.916314

target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

AGATA position +51-25 mm

TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000

all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise

There is no run 72

Stop at 2019-06-27 23:04:45.884452
Stop comment: AGATA DAQ is rejectting all events
Fixede768s Wed Jul 17 20:01:57 2019 OttoRunRUNGeneralN/ARun73
*************************
Run : 73
*************************

Start at 2019-07-17 20:00:28.897236

Time calibrator starting from MG3
strip by strip

Range 640 ns
Period 160 ns

Stop at 2019-07-18 00:16:51.295899
Stop comment:
Fixede744s Thu Apr 11 03:21:14 2019 OttoRunRUNGeneralCH2Run72
*************************
Run : 72
*************************

Start at 2019-04-11 03:16:52.893246

Run Conditions:
  • Operator: A. Lemasson
  • Trigger: VAMOS
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+4
  • Brho = 0.486 Tm
  • CATS 2 IN


Comment:
DAQ Crash
Fixede768s Wed Jul 17 17:18:37 2019 OttoRunRUNGeneralLiFRun72
*************************
Run : 72
*************************

Start at 2019-07-17 17:11:53.463967

15N 1e8 pps
LiF target

Stop at 2019-07-17 19:39:32.941104
Stop comment:
Fixede744s Thu Apr 11 03:09:14 2019 OttoRunRUNGeneralCH2Run71
*************************
Run : 71
*************************

Start at 2019-04-11 03:08:43.011636

Run Conditions:
  • Operator: A. Lemasson
  • Trigger: VAMOS
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+4
  • Brho = 0.484 Tm
  • CATS 2 IN


Comment:
Changed Brho to 0.484 to move the beam oit

Stop on DAQ Crash
(03:11:50 - 11/04/2019) FATAL - log from NARVAL.NUMEXO2_61 - Bloc_Catcher.T_Communication : requested size too high available in actor 1024 requested in header 5376 do not use this actor

(03:11:50 - 11/04/2019) FATAL - log from NARVAL.NUMEXO2_61 - NUMEXO2_61 put sub system NARVAL in error with message :Bloc_Catcher.T_Communication : actor buffer size too small

(03:11:50 - 11/04/2019) ERROR - log from NARVAL.NUMEXO2_61 - Bloc_Catcher.T_Communication : BlC : exception,STORAGE_ERROR,s-intman.adb:136 explicit raise

(03:11:50 - 11/04/2019) ERROR - log from NARVAL.NUMEXO2_61 - Bloc_Catcher.T_Communication : BPR2 : exception,STORAGE_ERROR,s-intman.adb:136 explicit raise

(03:11:50 - 11/04/2019) ERROR - log from NARVAL.NUMEXO2_61 - Bloc_Catcher.T_Communication : BPR ,STORAGE_ERROR,s-intman.adb:136 explicit raise

(03:11:50 - 11/04/2019) ERROR - log from NARVAL.NUMEXO2_61 - Bloc_Catcher.T_Communication : exception ,STORAGE_ERROR,s-intman.adb:136 explicit raise

Stop at 2019-04-11 03:20:00.545286
Stop comment:
Fixede786s Thu Jun 27 18:48:51 2019 OttoRunRUNGeneralCryo-3HeRun71
*************************
Run : 71
*************************

Start at 2019-06-27 18:47:56.171341

target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

AGATA position +51-25 mm

TRIGGER :
- MG
- square (not biased)
- M2


all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise

Stop at 2019-06-27 20:23:56.630240
Stop comment:
Fixede768s Wed Jul 17 13:55:30 2019 OttoRunRUNGeneralLiFRun71
*************************
Run : 71
*************************

Start at 2019-07-17 13:54:44.082989

15N beam -- data tacking


Target #1 1.25 mg/cm2

Brho = 0.640 Tm


plastic off
diamond on

mask: +7 mm

no beam at the beginning; we are requesting it.

restart daq qfter chqngin MUST2 HV mainframe.

Stop at 2019-07-17 14:49:13.546336
Stop comment: beam is taken back