Fixed, e768s, Sat Jul 20 01:02:10 2019, Serge & Franco, OTHER, General, , Night shift beam & resync
|
timeline of run 116
00:xx resync Agata #13C
|
Fixed, e768s, Sat Jul 20 04:30:42 2019, Serge & Franco, RUN, General, LiF, screenshots run 116 @ 02h00 14x
|
|
Fixed, e768s, Sat Jul 20 04:47:49 2019, Serge & Franco, RUN, General, LiF, screenshots run 116 @ 04h30 15x
|
The rate in the diamond was decreasing even if the rate in VAMOS was more or less constant. Now it seems stabilized. |
Fixed, e768s, Sat Jul 20 05:58:18 2019, Franco, OFFLINE, General, , Time calibration for MG10_X 
|
Attached a tentative time calibration for the square MG10_X from run 89 (to be checked!).
Even applying the calibration the spectrum E_TOF for MG10 (run 115) displays many structures. |
Fixed, e768s, Sat Jul 20 08:01:06 2019, Nikola, ONLINE, General, , screenshots run 116 @ 08h00 22x
|
|
Fixed, e768s, Sat Jul 20 09:20:35 2019, Nikola, ONLINE, General, , screenshots run 116 @ 09h20 22x
|
|
Fixed, e768s, Sat Jul 20 10:50:01 2019, Nikola, ONLINE, General, , End of run 116 (beam problem) -> screenshots run 116 end @ 10h40 22x
|
1. A monitor of the primary beam failed and the astreinte had to be call (PCP did it).
2. The H2O cold box went in default. The cold water for AGATA digitizer; vamos crates and CTA went up to 25 deg!
|
Fixed, e768s, Sat Jul 20 11:33:01 2019, Christian, OTHER, General, , Previous Papers - gamma decays from states in the 4-MeV region
|
This search was triggered by our lack of seeing the 3958keV line at the expected level. 2689 keV line observed (runs 112,115,116) as 55-60 counts. Expected
yield in 3958 keV line based on 80:20 branching and 1.5:1.0 efficiency is 10 counts. We see (at most) 2 in the full photo-peak for this line. (Theses two
counts are also lower than expected by about 20 keV.)
|
Fixed, e768s, Sat Jul 20 12:06:00 2019, Christian, OTHER, General, , Previous Papers - gamma decays from states in the 4-MeV region
|
Further to the previous post on gamma-ray lines, attached is Kanungo's paper on doppler-attenuation measurement of the 4033 line for lifetime measurement.
The lower-energy lines are, however, not included in the figures. |
Fixed, e768s, Sat Jul 20 12:57:41 2019, Christian, OTHER, General, , Previous Papers - gamma decays from states in the 4-MeV region
|
2019 paper by Hall, Bardayan, et al., gamma decays of 4.14 and 4.20 states, g-g-t triple coincidences.
Abstract:
|
Fixed, e768s, Sat Jul 20 14:00:22 2019, OttoRun, RUN, General, LiF, Run117
|
*************************
[SIZE=3][B]Run : 117[/B][/SIZE]
*************************
|
Fixed, e768s, Sat Jul 20 14:21:22 2019, Nikola, ONLINE, General, , screenshots run 117 @ 14h20 22x
|
|
Fixed, e768s, Sat Jul 20 14:32:18 2019, Nicolas, BEAM, General, LiF, Beam profile & intensity (run 117 @ 14h30)
|
Beam intensity: 1.4e7 pps
VAMOS: ~ 1200 |
Fixed, e768s, Sat Jul 20 17:00:19 2019, OttoRun, RUN, General, LiF, Run118
|
*************************
[SIZE=3][B]Run : 118[/B][/SIZE]
*************************
|
Fixed, e768s, Sat Jul 20 17:03:23 2019, mugast, RUN, General, LiF, Run 117 stopped
|
Run 117 stopped because VAMOS VXI went offline |
Fixed, e768s, Sat Jul 20 17:06:12 2019, mugast, RUN, General, LiF, Run 118 Scaler
|
Start run 118 |
Fixed, e768s, Sat Jul 20 19:12:58 2019, Faïrouz & Sylvain, RUN, General, LiF, Run 118 screenshots @ 19h14 20x
|
|
Fixed, e768s, Sat Jul 20 19:21:56 2019, Marlene, Nicolas, Christian, Fairouz, OFFLINE, General, , Trying to understand AGATA g-ray yields
|
goal: we want to check whether the yields of the 1297.7 keV (from 19Ne 1536, 3/2+, l=1 state) and 1340 keV (from 19Ne 1615, 3/2-, l=2 state) g-ray lines
is compatible with what we expect from x-sec calculations
|
Fixed, e768s, Sat Jul 20 19:23:37 2019, Christiqn, OFFLINE, General, LiF, Ex in 19F from run 72
|
[B]Data: Total integral for peak region around 4 MeV in 19F during run 72:
[/B]
|
Fixed, e768s, Sat Jul 20 19:24:31 2019, Faïrouz & Sylvain, RUN, General, LiF, Beam intensity is decreasing.
|
The beam intensity decreased by half since 19h00 (600 in Vamos-or)due to the primary beam.
The operators are working on it since.
The intensity of 10^7 pps came back at 8 pm.
|
|