Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e768s |
Sun Jul 28 03:26:54 2019 |
Jenn and Andres | RUN | General | LiF | STOP RUN 154 |
At 3:00 am beam went off. We called PCP and they told us that they had some problems they need to fix and that it might take long.
Therefore we decided to stop the run and put the Faraday cup.
PCP will call when they deliver again the beam. |
Fixed | e744s |
Fri Apr 12 14:21:04 2019 |
OttoRun | RUN | General | CH2 | Run99 |
*************************
Run : 99
*************************
Start at 2019-04-12 14:20:41.671438
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: increasing intensity to 10kHz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Stop at 2019-04-12 14:27:41.833179
Stop comment: |
Fixed | e786s |
Mon Jul 1 16:47:40 2019 |
OttoRun | RUN | General | Cryo-3He | Run99 |
*************************
Run : 99
*************************
Start at 2019-07-01 16:45:20.515273
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
time calibration run
New line added just for clarity!!!
Bye Bye!
Salut!
Ok! Ok!
Stop at 2019-07-01 17:09:43.722886
Stop comment: MG11_MG7_X_time calibration |
Fixed | e744s |
Fri Apr 12 11:55:26 2019 |
OttoRun | RUN | General | CH2 | Run98 |
========================================
*************************
Run : 98
*************************
Start at 2019-04-12 11:54:05.693507
Run Conditions:
- Operator: Iulian ,Antoine, Diego
- Trigger: MUGAST + Vamos %100
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: increasing intensity to 10kHz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Stop at 2019-04-12 12:30:17.695767
Stop comment: Stoping to give beam to IBE to do reference Measurement |
Attachment 1: run98_Vamos_1.png
|
|
Attachment 2: run98_Vamos_2.png
|
|
Attachment 3: run98_Vamos_3.png
|
|
Attachment 4: run98_Vamos_4.png
|
|
Attachment 5: run98_Vamos_5.png
|
|
Attachment 6: run98_Vamos_6.png
|
|
Attachment 7: run98_Vamos_7.png
|
|
Attachment 8: run98_Vamos_8.png
|
|
Attachment 9: run98_Vamos_9.png
|
|
Attachment 10: run98_Vamos_10.png
|
|
Attachment 11: run98_Vamos_11.png
|
|
Attachment 12: run98_Vamos_12.png
|
|
Fixed | e744s |
Fri Apr 12 12:04:55 2019 |
OttoRun | RUN | General | CH2 | Run98 |
OttoRun wrote: | *************************
Run : 98
*************************
Start at 2019-04-12 11:54:05.693507
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: increasing intensity to 10kHz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Trip of DC2_W : Reducing HV of DC2_W from 650 to 620V
|
|
Fixed | e786s |
Mon Jul 1 16:22:29 2019 |
OttoRun | RUN | General | Cryo-3He | Run98 |
*************************
Run : 98
*************************
Start at 2019-07-01 16:21:29.792984
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
time calibration run
New line added just for clarity!!!
Bye Bye!
Salut!
Ok! Ok!
Stop at 2019-07-01 16:22:31.326284
Stop comment:
Stop at 2019-07-01 16:46:37.614243
Stop comment: MG1_MG3_MG4_MG5_Y_time calibration |
Fixed | e744s |
Fri Apr 12 11:29:46 2019 |
OttoRun | RUN | General | CH2 | Run97 |
*************************
Run : 97
*************************
Start at 2019-04-12 11:29:03.948068
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Correct TAC T_FPMW_XXX FPMW Fifo Pb with 50 ohm terminator ...
Stop at 2019-04-12 11:45:25.662355
Stop comment: Entering to Set Vamos %100 |
Fixed | e786s |
Mon Jul 1 15:57:15 2019 |
OttoRun | RUN | General | Cryo-3He | Run97 |
*************************
Run : 97
*************************
Start at 2019-07-01 15:57:12.588104
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
time calibration run
New line added just for clarity!!!
Bye Bye!
Salut!
Ok! Ok! |
Fixed | e744s |
Fri Apr 12 10:37:03 2019 |
OttoRun | RUN | General | CH2 | Run96 |
*************************
Run : 96
*************************
Start at 2019-04-12 10:36:45.359601
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Timing Setting
Stop at 2019-04-12 11:16:49.078211
Stop comment: Entering Change Delay on T_FPMW_CATS2 |
Fixed | e786s |
Tue Jul 2 10:30:10 2019 |
OttoRun | RUN | General | Cryo-3He | Run96 |
*************************
Run : 96
*************************
Start at 2019-07-01 15:39:55.733031
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
time calibration run
New line added just for clarity!!!
Bye Bye!
Salut!
Ok! Ok!
Stop at 2019-07-02 10:30:11.518345
Stop comment:
Stop at 2019-07-02 10:30:44.954507
Stop comment: |
Fixed | e744s |
Fri Apr 12 10:17:57 2019 |
OttoRun | RUN | General | CH2 | Run95 |
*************************
Run : 95
*************************
Start at 2019-04-12 10:09:45.911078
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
working inside G1
Stop at 2019-04-12 10:33:06.491018
Stop comment: |
Fixed | e786s |
Mon Jul 1 17:56:36 2019 |
OttoRun | RUN | General | Cryo-3He | Run95 |
*************************
Run : 95
*************************
Start at 2019-07-01 15:15:38.418712
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
time calibration run
New line added just for clarity!!!
Bye Bye!
Salut!
Ok! Ok! |
Fixed | e744s |
Fri Apr 12 09:41:38 2019 |
OttoRun | RUN | General | CH2 | Run94 |
*************************
Run : 94
*************************
Start at 2019-04-12 09:41:27.977232
Run Conditions:
- Operator: Louis
- Trigger: MUGAST + Vamos
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Stop at 2019-04-12 10:11:29.453680 |
Attachment 1: run94_9.png
|
|
Attachment 2: run94_8.png
|
|
Attachment 3: run94_7.png
|
|
Attachment 4: run94_6.png
|
|
Attachment 5: run94_5.png
|
|
Attachment 6: run94_4.png
|
|
Attachment 7: run94_3.png
|
|
Attachment 8: run94_2.png
|
|
Attachment 9: run94_1.png
|
|
Attachment 10: run94_scaler3.png
|
|
Attachment 11: run94_scaler2.png
|
|
Attachment 12: run94_ELabThetaLabrun87_E745_HFvsCATS.png
|
|
Fixed | e786s |
Mon Jul 1 14:51:23 2019 |
OttoRun | RUN | General | Cryo-3He | Run94 |
Stop at 2019-07-01 15:20:53.693416
Stop comment: time calibration mugast
Stop at 2019-07-01 15:42:57.994760
Stop comment: MG1Y_MG3Y_MG4Y_MG5Y time calibration
Stop at 2019-07-01 15:47:55.828680
Stop comment: |
Fixed | e768s |
Thu Jul 18 17:12:35 2019 |
OttoRun | RUN | General | N/A | Run94 |
*************************
Run : 94
*************************
Start at 2019-07-18 17:11:31.161368
Pedestal calibration of MUGAST /MUST2 detectors WITHOUT PEDESTAL ALIGNMENT
Internal Pulser on channel 1 of Mate 1 X
Try with new pedestals of MG3 (measured at 17h11 and saved as pedestal_muvi2sec2_18juil19)
Previous pedestals were saved as pedestal_muvi2sec2
Stop at 2019-07-18 17:21:20.999926
Stop comment:
Stop at 2019-07-19 00:01:38.322738
Stop comment:
Stop at 2019-07-19 00:01:38.721275
Stop comment:
Stop at 2019-07-19 00:01:38.904181
Stop comment:
Stop at 2019-07-19 00:01:39.088224
Stop comment: |
Fixed | e744s |
Fri Apr 12 09:37:43 2019 |
OttoRun | RUN | General | CH2 | Run93 |
*************************
Run : 93
*************************
Start at 2019-04-12 09:37:36.997465
Run Conditions:
- Operator: Louis
- Trigger: MUST2
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open |
Fixed | e786s |
Mon Jul 1 14:18:15 2019 |
OttoRun | RUN | General | Cryo-3He | Run93 |
*************************
Run : 93
*************************
Start at 2019-07-01 14:17:11.114408
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
time calibration run
New line added just for clarity!!!
Au revoir!
Salut!
Ok! Ok!
Stop at 2019-07-01 14:18:17.386903
Stop comment: |
Fixed | e768s |
Thu Jul 18 16:51:13 2019 |
OttoRun | RUN | General | N/A | Run93 |
*************************
Run : 93
*************************
Start at 2019-07-18 16:51:02.999421
Pedestal calibration of MUGAST /MUST2 detectors WITHOUT PEDESTAL ALIGNMENT
Internal Pulser on channel 1 of Mate 1 X
Correct file
Stop at 2019-07-18 16:59:04.056903
Stop comment: |
Fixed | e744s |
Fri Apr 12 09:33:33 2019 |
OttoRun | RUN | General | CH2 | Run92 |
*************************
Run : 92
*************************
Start at 2019-04-12 09:33:19.869189
Run Conditions:
- Operator: Louis
- Trigger: MUST2
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: reduced to ~ 300 Hz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
After rebboting ganlx7 (VAMOS_VME)
Stop at 2019-04-12 09:37:30.065218
Stop comment: Start did not Start ! |
Fixed | e786s |
Mon Jul 1 13:53:01 2019 |
OttoRun | RUN | General | Cryo-3He | Run92 |
*************************
Run : 92
*************************
Start at 2019-07-01 13:52:47.447528
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
time calibration run
New line added just for clarity!!!
Au revoir!
Salut!
Ok! Ok! |