Fixed, e768s, Fri Jul 19 00:01:40 2019, OttoRun, RUN, General, N/A, Run102
|
*************************
Run : 102
*************************
Start at 2019-07-18 23:39:03.248989
Pedestal calibration of MUGAST /MUST2 detectors WITHOUT PEDESTAL ALIGNMENT
Internal Pulser on channel 1 of Mate 1 X
Try with new pedestals of MG3 (measured at 17h11 and saved as pedestal_muvi2sec2_18juil19)
Previous pedestals were saved as pedestal_muvi2sec2 |
Fixed, e768s, Fri Jul 19 00:01:41 2019, OttoRun, RUN, General, N/A, Run101
|
*************************
Run : 101
*************************
Start at 2019-07-18 23:35:13.491314
Pedestal calibration of MUGAST /MUST2 detectors WITHOUT PEDESTAL ALIGNMENT
Internal Pulser on channel 1 of Mate 1 X
Try with new pedestals of MG3 (measured at 17h11 and saved as pedestal_muvi2sec2_18juil19)
Previous pedestals were saved as pedestal_muvi2sec2 |
Fixed, e768s, Fri Jul 19 00:01:42 2019, OttoRun, RUN, General, N/A, Run103
|
*************************
Run : 103
*************************
Start at 2019-07-18 23:42:22.128470
Pedestal calibration of MUGAST /MUST2 detectors WITHOUT PEDESTAL ALIGNMENT
Internal Pulser on channel 1 of Mate 1 X
Try with new pedestals of MG3 (measured at 17h11 and saved as pedestal_muvi2sec2_18juil19)
Previous pedestals were saved as pedestal_muvi2sec2 |
Fixed, e768s, Fri Jul 19 00:01:43 2019, OttoRun, RUN, General, N/A, Run100
|
*************************
Run : 100
*************************
Start at 2019-07-18 23:15:56.464535
Pedestal calibration of MUGAST /MUST2 detectors WITHOUT PEDESTAL ALIGNMENT
Internal Pulser on channel 1 of Mate 1 X
Try with new pedestals of MG3 (measured at 17h11 and saved as pedestal_muvi2sec2_18juil19)
Previous pedestals were saved as pedestal_muvi2sec2
Stop at 2019-07-19 00:08:11.676196
Stop comment: |
Fixed, e768s, Fri Jul 19 00:03:25 2019, Jenn, BEAM, General, , Brho information 15 Oxygen beam 4.7MeV/u
|
|
Fixed, e768s, Fri Jul 19 00:06:35 2019, Jenn, BEAM, General, , Brho information 15 Oxygen beam 4.7MeV/u
|
|
Fixed, e768s, Fri Jul 19 00:08:13 2019, OttoRun, RUN, General, N/A, Run104
|
*************************
Run : 104
*************************
Start at 2019-07-19 00:06:02.719387
Pedestal calibration of MUGAST /MUST2 detectors WITHOUT PEDESTAL ALIGNMENT
Internal Pulser on channel 1 of Mate 1 X
Try with new pedestals of MG3 (measured at 17h11 and saved as pedestal_muvi2sec2_18juil19)
Previous pedestals were saved as pedestal_muvi2sec2 |
Fixed, e768s, Fri Jul 19 00:08:51 2019, OttoRun, RUN, General, N/A, Run105 
|
*************************
Run : 105
*************************
Start at 2019-07-19 00:08:48.562904
Tuning 15O beam to center on optical axis and remove contribution from natC part of the target
Stop at 2019-07-19 00:58:24.956373
Stop comment: |
Fixed, e768s, Fri Jul 19 00:59:00 2019, OttoRun, RUN, General, LiF, Run106
|
*************************
Run : 106
*************************
Start at 2019-07-19 00:58:37.270080
Stop at 2019-07-19 01:00:43.108147
Stop comment: |
Fixed, e768s, Fri Jul 19 00:59:20 2019, mugast, RUN, General, , RUN 107 - Reference Target Run
|
Reference Target Run after beam tuning
Brho 0.5854 Tm |
Fixed, e768s, Fri Jul 19 01:02:54 2019, mugast, OTHER, General, , 15O beam parameters
|
Brho manip = Brho after target - 2% = 0.556 Tm
RMN = 2821.476 Gauss
Q32 = 15.2 A
Q31 = 16.8 A
Q41 = 148.070 A
Q42 = 217.452 A
Dipole D4p = 187.632 A |
Fixed, e768s, Fri Jul 19 01:05:26 2019, mugast, RUN, General, , RUN 108
|
Brho Change to 0.556 Tm
Moving Plate : Final Position +7mm
with 6 kHz
Slowly increasing |
Fixed, e768s, Fri Jul 19 01:32:17 2019, OttoRun, RUN, General, LiF, Run107
|
*************************
Run : 107
*************************
Start at 2019-07-19 01:00:49.000867
Stop at 2019-07-19 01:32:18.881037
Stop comment: |
Fixed, e768s, Fri Jul 19 01:32:20 2019, OttoRun, RUN, General, LiF, Run108
|
*************************
Run : 108
*************************
Start at 2019-07-19 01:05:04.198626
Stop at 2019-07-19 02:01:09.195123
Stop comment:
Stop at 2019-07-19 02:16:54.064899
Stop comment: |
Fixed, e768s, Fri Jul 19 02:19:51 2019, OttoRun, RUN, General, LiF, Run110
|
*************************
Run : 110
*************************
Start at 2019-07-19 02:13:34.456709
RUN 110 Coupled with AGATA
15O : 1e7 pps
Brho 0.656
target 1.25 mg/cm 7LiF |
Fixed, e768s, Fri Jul 19 02:22:12 2019, OttoRun, RUN, General, LiF, Run111
|
*************************
Run : 111
*************************
Start at 2019-07-19 02:19:49.799405
JUNK
10 Coupled with AGATA
15O : 1e7 pps
Brho 0.656
target 1.25 mg/cm 7LiF
Stop at 2019-07-19 02:22:24.337284
Stop comment: |
Fixed, e768s, Fri Jul 19 02:27:22 2019, OttoRun, RUN, General, LiF, Run112
|
*************************
Run : 112
*************************
Start at 2019-07-19 02:25:09.701469
coupled with AGATA
15O @ 1.5e7 ppps
Brho=0.556
Target : LiF n°1 1.25 mg/cm2
trigger :
MG
square
MM
Vamos%100
BaF2%100
removed suppression of overflow in energy for MM & square
Stop at 2019-07-19 10:07:19.632461
Stop comment: |
Fixed, e768s, Fri Jul 19 03:29:58 2019, Jenn, ONLINE, General, LiF, Screenshots run 112 overnight 16x
|
MUGAST and VAMOS screenshots run 112 |
Fixed, e768s, Fri Jul 19 08:09:21 2019, Jenn, Kseniia, OTHER, General, , Overview nightshift run 112
|
Smooth night, everything was working properly.
Checked agata rootfile to see preliminary gammas.
19Ne 275 state observed
Also 19F (strong 109 state) (fusion-evaporation?)
Check Agata elog for more details. |
Fixed, e768s, Fri Jul 19 09:32:45 2019, mugast, BEAM, General, LiF, Beam is fluctuating
|
There was a temporary beam loss during the run 113 |
|