Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | TEST |
Fri Apr 12 16:53:08 2019 |
OttoH.V. | OTHER | Hardware | N/A | HVM_ERROR |
*** hvm watcher error ***
FP_CATS0 Slot: 2 (A1821HMP) Channel:6 Vmon: 549.5 V Imon: 0.999 uA Status: OVER CURRENT
|
Fixed | e744s |
Fri Apr 12 16:55:38 2019 |
OttoRun | RUN | General | N/A | Run108 |
*************************
Run : 108
*************************
Start at 2019-04-12 16:55:34.729059
Run Conditions:
- Operator: Emmanuel
- Trigger: AGATA
Comment:
AGATA DAQ TEST
Stop at 2019-04-12 16:57:48.492790
Stop comment:
Stop at 2019-04-12 17:16:03.912919
Stop comment: type your message here |
Fixed | e744s |
Fri Apr 12 17:12:42 2019 |
Antoine | OFFLINE | General | CH2 | 13N identified in VAMOS |
Identification plots.
left: Z versus A/Q, 3 plots are visibles for the three charge states of 14O 8+, 7+, 6+
middle: Delta versus E. Oxygen is identified.
right: when a cut is made on the first figure with Z=7 and A/Q= 13/7=1.85, and applied to the figure in the right, it confirms 13N. |
Fixed | e744s |
Fri Apr 12 17:16:16 2019 |
OttoRun | RUN | General | N/A | Run109 |
*************************
Run : 109
*************************
Start at 2019-04-12 17:13:28.183301
Run Conditions:
- Operator: Emmanuel
- Trigger: AGATA
Comment:
AGATA DAQ TEST |
Fixed | e744s |
Fri Apr 12 19:44:09 2019 |
diego | VAMOS | Software | | SetAlias script for VAMOS identification |
|
Fixed | e744s |
Fri Apr 12 20:17:52 2019 |
mugast | VAMOS | General | | Increasing Pressure VAMOS IC |
We have increased the pressure of VAMOS-IC from 50 mbar to 55 mbar in order to stop the beam in the pad n4 and not having few MeV of remaining energy in the pad n5.
Votage related:
HV(IC_wires) = 495 V
HV(IC_pads) = 165 V
HV(IC_cathode) = 1232 V |
Fixed | e744s |
Fri Apr 12 20:31:24 2019 |
OttoRun | RUN | General | CH2 | Run103 |
*************************
Run : 103
*************************
Start at 2019-04-12 15:54:57.632048
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: increasing intensity to 10kHz
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open |
Fixed | e744s |
Fri Apr 12 20:36:44 2019 |
OttoRun | RUN | General | CH2 | Run110 |
*************************
Run : 110
*************************
Start at 2019-04-12 20:33:38.651697
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- Target/Source: CH2 target 2
- Beam: 14O
- Intensity: variable
- Brho = 0.5283 Tm
- !CATS/VAMOS (CATS Efficiency)! : XXXX
Comment:
Start Target 2: 104 um
VAMOS is Open
Stop at 2019-04-12 20:46:15.219068
Stop comment: |
Fixed | TEST |
Fri Apr 12 20:41:39 2019 |
OttoH.V. | OTHER | Hardware | N/A | HVM_ERROR |
*** hvm watcher error ***
FP_DC2_w2 Slot: 2 (A1821HMP) Channel:3 Vmon: 619.75 V Imon: 0.005 uA Status: OVER CURRENT
|
Fixed | e744s |
Fri Apr 12 20:57:42 2019 |
OttoRun | RUN | General | CH2 | Run111 |
*************************
Run : 111
*************************
Start at 2019-04-12 20:57:19.575895
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- No target
- Beam: 14O
- Intensity: variable
- Brho = Unknown Brho
- No CATS
Comment:
VAMOS is Open
Stop at 2019-04-12 21:04:29.129282
Stop comment: useless run |
Fixed | e744s |
Fri Apr 12 21:13:49 2019 |
OttoRun | RUN | General | CH2 | Run112 |
*************************
Run : 112
*************************
Start at 2019-04-12 21:13:17.592474
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- Hole target
- Beam: 14O
- Intensity: variable
- Brho = 0.6912 Tm
- No CATS
Comment:
VAMOS is Open
Stop at 2019-04-12 21:20:05.301553
Stop comment: Entering to insert CATS2 |
Fixed | e744s |
Fri Apr 12 21:29:17 2019 |
OttoRun | RUN | General | CH2 | Run113 |
*************************
Run : 113
*************************
Start at 2019-04-12 21:28:46.762578
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- Hole target
- Beam: 14O
- Intensity: variable
- Brho = 0.6912 Tm
- CATS2 in
Comment:
VAMOS is Open |
Fixed | e744s |
Fri Apr 12 21:43:16 2019 |
OttoRun | RUN | General | CH2 | Run114 |
*************************
Run : 114
*************************
Start at 2019-04-12 21:42:12.558669
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- No target
- Beam: 14O
- Intensity: variable
- Brho = 0.6912 Tm
- CATS2 in
Comment:
VAMOS is Open
Stop at 2019-04-12 22:04:01.062421
Stop comment: test run |
Fixed | e744s |
Fri Apr 12 22:00:42 2019 |
Diego | TARGET | General | | very different target thickness |
|
Fixed | e744s |
Fri Apr 12 22:16:33 2019 |
OttoRun | RUN | General | CH2 | Run115 |
*************************
Run : 115
*************************
Start at 2019-04-12 22:15:31.632167
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- Target #3
- Beam: 14O
- Intensity: variable
- Brho = 0.5473 Tm
- CATS2 in
Comment:
VAMOS is Open
Stop at 2019-04-12 22:25:11.807535
Stop comment: Stopin to change Brho |
Fixed | e744s |
Fri Apr 12 22:28:15 2019 |
OttoRun | RUN | General | CH2 | Run116 |
*************************
Run : 116
*************************
Start at 2019-04-12 22:27:56.420427
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- Target #3
- Beam: 14O
- Intensity: variable
- Brho = 0.5199 Tm
- CATS2 in
Comment:
VAMOS is Open
Stop at 2019-04-12 22:32:41.994133
Stop comment: |
Fixed | e744s |
Fri Apr 12 22:33:22 2019 |
OttoRun | RUN | General | CH2 | Run117 |
*************************
Run : 117
*************************
Start at 2019-04-12 22:32:45.436663
Run Conditions:
- Operator: Antoine
- Trigger: MUGAST + Vamos %100
- Target #3
- Beam: 14O
- Intensity: variable
- Brho = 0.5199 Tm
- CATS2 in
- Finger Plancement
Comment:
Moving The finger
VAMOS is Open
Stop at 2019-04-12 22:39:59.872754
Stop comment: finger position at +12 mm |
Fixed | e744s |
Fri Apr 12 22:40:26 2019 |
OttoRun | RUN | General | CH2 | Run118 |
*************************
Run : 118
*************************
Start at 2019-04-12 22:40:07.011114
Run Conditions:
- Operator: Antoine
- Trigger: MUGAST + Vamos %100
- Target #3
- Beam: 14O
- Intensity: variable
- Brho = 0.5199 Tm
- CATS2 in
- Finger at +12 mm
Comment:
Moving The finger
VAMOS is Open
Stop at 2019-04-12 23:02:06.020781
Stop comment: Stoping to change CATS (1->%30000) and VAMOS Div (100->1000) |
Fixed | e744s |
Fri Apr 12 22:44:43 2019 |
Valerian and Diego | OFFLINE | Software | CH2 | 13N measured in Vamos do correspond to protons events in MUST2 |
Doing a cut on M vs M/Q corresponding to 13N one can see that most of the events do correspond to protons events in MUST2!!! |
Fixed | e744s |
Fri Apr 12 23:17:13 2019 |
OttoRun | RUN | General | CH2 | Run119 |
*************************
Run : 119
*************************
Start at 2019-04-12 23:15:13.390175
Run Conditions:
- Operator: Antoine
- Trigger: MUGAST + Vamos %1000 + CATS %30000
- Target #3
- Beam: 14O
- Intensity: ~6e4
- Brho = 0.5199 Tm
- CATS2 in
- Finger at +12 mm
- WITH AGATA
Comment:
VAMOS is Open
AGATA Coupling
Stop at 2019-04-13 00:42:48.531750
Stop comment: beam down because of heating |