ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Fixed
TEST
Tue Apr 16 10:07:46 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
cats2
Slot:
13
(A1835 ) Channel:
1
Vmon:
552.5 V
Imon:
0.28 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 10:15:18 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
cats2
Slot:
13
(A1835 ) Channel:
1
Vmon:
555.2 V
Imon:
0.2 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 10:22:49 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
cats2
Slot:
13
(A1835 ) Channel:
1
Vmon:
553 V
Imon:
0.9 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 10:28:45 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
cats2
Slot:
13
(A1835 ) Channel:
1
Vmon:
555.1 V
Imon:
0.18 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 10:36:09 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
cats2
Slot:
13
(A1835 ) Channel:
1
Vmon:
553.7 V
Imon:
0.24 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 10:56:31 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
cats2
Slot:
13
(A1835 ) Channel:
1
Vmon:
553.9 V
Imon:
0.28 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 11:33:26 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_DC1_w1
Slot:
2
(A1821HMP) Channel:
0
Vmon:
663.5 V
Imon:
0.111 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 11:34:13 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_CATS1
Slot:
2
(A1821HMP) Channel:
7
Vmon:
569.25 V
Imon:
0.059 uA
Status:
OVER CURRENT
Fixed
e744s
Tue Apr 16 11:40:04 2019
mugast
CATS
Hardware
N/A
CATS HV
CATS2 HV was decreased to 540 V at 11h30 to avoid the overcurrent.
Need to monitor Efficiency, Time resolution as soon as the run restart with new target.
Fixed
TEST
Tue Apr 16 11:40:13 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_DC2_w2
Slot:
2
(A1821HMP) Channel:
3
Vmon:
598.5 V
Imon:
0.297 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 12:01:06 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_DC2_w2
Slot:
2
(A1821HMP) Channel:
3
Vmon:
596 V
Imon:
0.384 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 12:06:18 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_DC2_w2
Slot:
2
(A1821HMP) Channel:
3
Vmon:
574 V
Imon:
0.569 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 12:11:21 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_DC2_w2
Slot:
2
(A1821HMP) Channel:
3
Vmon:
588.75 V
Imon:
0.389 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 12:18:00 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_DC2_w2
Slot:
2
(A1821HMP) Channel:
3
Vmon:
566.25 V
Imon:
0.655 uA
Status:
OVER CURRENT
Fixed
Tue Apr 16 12:18:46 2019
AGATA
AGATA
Hardware
ATC4 - position 13 HV tripped
- HV tripped around 12h10.
- need access to check the origin
Fixed
TEST
Tue Apr 16 12:22:24 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_DC2_w2
Slot:
2
(A1821HMP) Channel:
3
Vmon:
612 V
Imon:
0.171 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 12:27:37 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_DC2_w2
Slot:
2
(A1821HMP) Channel:
3
Vmon:
571.5 V
Imon:
0.539 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 12:32:59 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_DC2_w2
Slot:
2
(A1821HMP) Channel:
3
Vmon:
499.75 V
Imon:
0.998 uA
Status:
OVER CURRENT
Fixed
TEST
Tue Apr 16 12:38:18 2019
OttoH.V.
OTHER
Hardware
N/A
HVM_ERROR
*** hvm watcher error ***
FP_DC2_w2
Slot:
2
(A1821HMP) Channel:
3
Vmon:
619.75 V
Imon:
0.039 uA
Status:
OVER CURRENT
Fixed
Tue Apr 16 13:15:48 2019
AGATA
AGATA
Hardware
ATC4 - position 13 HV tripped
set 1500 V at 13h15