MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 1 of 132  Not logged in MUGAST
Pinned, TEST, Tue Feb 26 09:30:21 2019, Freddy, OTHER, Hardware, N/A, Cabling - MUVI / HT-BT / SA-SL Cabling_2019_03_01.pdf
Cabling scheme - to update until final
Pinned, com2019, Mon Apr 1 11:02:00 2019, Adrien Matta, MUST2, Hardware, N/A, Switching on and off LV/HV for MUST2 crate 
[SIZE=4]HVM group could be used to switch on and off the LV and HV for the MUST2 crate.
[I]
The command could be lauched from the analysis environment: start a terminal and type:[/I]
Pinned, com2019, Thu Apr 4 14:45:53 2019, Valerian, OTHER, Hardware, N/A, Surveyor's measurements GANIL-0057_E744_I-Stefan.pdfE744_XYZ_détecteurs_Si.xlsx
Summary of the Surveyors. Joined the pdf and the Excel file
Pinned, com2019, Fri Apr 5 23:34:46 2019, Adrien et Valerian, OFFLINE, General, N/A, Converting data and adding stat to Kine Plot 
Here is a procedure to convert a run and add data the Kinematic plot.

Every 4Go there will be a file change, convert the file and add it to the chain using the following step:
Pinned, e744s, Wed Apr 10 11:57:37 2019, A. Lemasson, OFFLINE, Software, , VAMOS Conversion HowTo 

[B]HOW TO convert a run in VAMOS[/B] 
[LIST]
Pinned, e786s, Wed Apr 10 13:30:48 2019, Valerian, Adrien and Antoine (edit by Louis), OFFLINE, Software, N/A, How to perform analysis for e786s 
[U][B]
Here is the updated procedure to convert a run, with VAMOS data and add those data to the Kinematic plot.
[/B][/U]
Pinned, e768s, Sat Jul 27 04:12:57 2019, Sylvain & Freddy, BEAM, General, LiF, Run 152 - Scaler & screenshot + Beam profile 14x
 
Pinned, e768s, Sat Jul 27 06:47:16 2019, Sylvain & Andrea, OTHER, General, LiF, Water tray of MUGAST air conditioner cooling system is almost full 
During a room inspection it was notice that the water tray used as an output of the fan system which is cooling MUGAST electronic crates is almost full
of water. The floor is dry but the we suspect a leakage from the air conditioner. To avoid to flood the floor we took some of the water and put in in the
water tray of the fan system located in front of VAMOS.
Pinned, e775s, Thu Feb 27 12:44:37 2020, Nicolas, OFFLINE, Software, , How to produce control spectra 
In /home/mugast/analysis/nptool/Projects/MUGAST/e775s directory there is the Control.C macro which draws: Ex, Ex vs Eg and Elab vs thetalab for each run
(run number must be given in argument) or for chained runs (argument must be 0)
    Pinned, e775s, Thu Feb 27 16:35:26 2020, Nicolas, OFFLINE, Software, , How to produce control spectra 
[quote="Nicolas"]In /home/mugast/analysis/nptool/Projects/MUGAST/e775s directory there is the Control.C macro which draws: Ex, Ex vs Eg and Elab vs thetalab
for each run (run number must be given in argument) or for chained runs (argument must be 0)[/quote]
Pinned, e793s, Tue Mar 9 09:35:18 2021, Adrien, OTHER, General, N/A, E793s proposal Proposal_K48_by_dp_MUGAST_FINAL.pdf
[SIZE=6][B]Attached is the proposal of the experiment.[/B][/SIZE]
Pinned, e793s, Wed Mar 10 13:10:14 2021, Adrien, BEAM, General, CD2, Kinematical line from Ti contamination KineTiK.pdfKine.cxx
In black the Kinematical line for states known to be populated strongly in 47Ti(d,p).
In blue range of the states of interrest.
Pinned, e793s, Fri Mar 12 15:48:35 2021, Adrien, RUN, General, N/A, Vamos D and Q value and MW HV  
 
Pinned, e793s, Fri Mar 12 15:50:12 2021, Adrien, RUN, General, N/A, Vamos D and Q value and MW HV  1613EC0C-1F4A-4933-B90A-D98A37421BFF.jpeg4ACA3448-35FF-472C-977C-E642B4ADE6A6.jpeg
Attached are the value for D and Q pole of vamos in case they trip.
Also attached is the computer driving the HV of the focal plan.
Pending, , Fri Jul 26 11:25:46 2019, UK refugees, OTHER, General, , Be positive and the experiment will work if we put lead in our pencil bojoonazipwire.jpg
 
Pending, TEST, Fri Jul 26 13:12:59 2019, OttoH.V., OTHER, Hardware, N/A, HVM_ERROR 
[SIZE=5][COLOR=red][B]*** hvm watcher error ***[/B] [/COLOR][/SIZE] 
 [SIZE=4][COLOR=green]FP_CATS4    [/COLOR] Slot: [COLOR=blue]2  [/COLOR] (A1821HMP) Channel:[COLOR=blue]10[/COLOR]  Vmon: [COLOR=blue]  515 V  [/COLOR]
Imon: [COLOR=blue] 0.96 uA[/COLOR] Status: [COLOR=red]OVER CURRENT[/COLOR]
Pending, TEST, Tue Jan 21 17:55:12 2020, Marlne, MUST2, Hardware, , Ovv error on the -5V of CAEN boards BT_referenve_5V_cables_inv_a_comp_referenve_5V_partMUST2BT_referenve_5V_partMUST2_cables_inv_a_comp_referenve_5VBT_referenve_5V_partMUST2BT_referenve_5V
The Ovv error shows on the -5V (first one) of the 3 board (5,3.3,10V for MUST2squares)
It means that the voltage is over the asked value.
If we ask 5V, we get 5.5V in reality
Pending, TEST, Mon Feb 24 09:16:59 2020, OttoH.V., OTHER, Hardware, N/A, HVM_ERROR 
[SIZE=5][COLOR=red][B]*** hvm watcher error ***[/B] [/COLOR][/SIZE] 
 [SIZE=4][COLOR=green]FP_CATS4    [/COLOR] Slot: [COLOR=blue]2  [/COLOR] (A1821HMP) Channel:[COLOR=blue]10[/COLOR]  Vmon: [COLOR=blue]  0.5 V  [/COLOR]
Imon: [COLOR=blue] 0.06 uA[/COLOR] Status: [COLOR=red]INTERNAL TRIP[/COLOR]
Pending, TEST, Mon Feb 24 11:54:50 2020, OttoH.V., OTHER, Hardware, N/A, HVM_ERROR 
[SIZE=5][COLOR=red][B]*** hvm watcher error ***[/B] [/COLOR][/SIZE] 
 [SIZE=4][COLOR=green]FP_CATS1    [/COLOR] Slot: [COLOR=blue]2  [/COLOR] (A1821HMP) Channel:[COLOR=blue]7 [/COLOR]  Vmon: [COLOR=blue] 0.75 V  [/COLOR]
Imon: [COLOR=blue]    0 uA[/COLOR] Status: [COLOR=red]INTERNAL TRIP[/COLOR]
Pending, TEST, Tue Feb 25 14:43:16 2020, OttoH.V., OTHER, Hardware, N/A, HVM_ERROR 
[SIZE=5][COLOR=red][B]*** hvm watcher error ***[/B] [/COLOR][/SIZE] 
 [SIZE=4][COLOR=green]FP_CATS0    [/COLOR] Slot: [COLOR=blue]2  [/COLOR] (A1821HMP) Channel:[COLOR=blue]6 [/COLOR]  Vmon: [COLOR=blue]  6.5 V  [/COLOR]
Imon: [COLOR=blue]    0 uA[/COLOR] Status: [COLOR=red]INTERNAL TRIP[/COLOR]

ELOG Home Page