Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e786s |
Thu Jun 27 17:59:20 2019 |
OttoRun | RUN | General | Cryo-3He | Run70 |
*************************
Run : 70
*************************
Start at 2019-06-27 17:58:29.855367
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
back to normal
Stop at 2019-06-27 18:37:51.816766
Stop comment: type your message here |
Fixed | e786s |
Thu Jun 27 18:48:51 2019 |
OttoRun | RUN | General | Cryo-3He | Run71 |
*************************
Run : 71
*************************
Start at 2019-06-27 18:47:56.171341
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- MG
- square (not biased)
- M2
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
Stop at 2019-06-27 20:23:56.630240
Stop comment: |
Fixed | e786s |
Thu Jun 27 20:26:27 2019 |
OttoRun | RUN | General | Cryo-3He | Run73 |
*************************
Run : 73
*************************
Start at 2019-06-27 20:26:17.916314
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
There is no run 72
Stop at 2019-06-27 23:04:45.884452
Stop comment: AGATA DAQ is rejectting all events |
Fixed | e786s |
Thu Jun 27 23:28:30 2019 |
OttoRun | RUN | General | Cryo-3He | Run74 |
*************************
Run : 74
*************************
Start at 2019-06-27 23:25:00.455575
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
Stop at 2019-06-28 09:31:40.775271
Stop comment: |
Fixed | e786s |
Fri Jun 28 04:21:48 2019 |
Daniele Mengoni | RUN | General | Cryo-3He | run 74 |
screenshots run 74 attached
frequent error message on the FP DC Wi1 --> defqlt. The elog said so, card tripped, but spectra are still present .. puzzling |
Attachment 1: Q_vs_Xf_K1.png
|
|
Attachment 2: Q_vs_Xf_K2.png
|
|
Attachment 3: Q_vs_Xf_K3.png
|
|
Attachment 4: Q_vs_Xf_K4.png
|
|
Attachment 5: Q_vs_Xf_K5.png
|
|
Attachment 6: Q_vs_Xf_K6.png
|
|
Attachment 7: Q_vs_Xf_K7.png
|
|
Attachment 8: Q_vs_Xf_K8.png
|
|
Attachment 9: Q_vs_Xf_K9.png
|
|
Attachment 10: Q_vs_Xf_K10.png
|
|
Attachment 11: Q_vs_Xf_K11.png
|
|
Attachment 12: Q_vs_Xf_K12.png
|
|
Attachment 13: Q_vs_Xf_K13.png
|
|
Attachment 14: Q_vs_Xf_K14.png
|
|
Attachment 15: Q_vs_Xf_K15.png
|
|
Attachment 16: Q_vs_Xf_K16.png
|
|
Attachment 17: Q_vs_Xf_K17.png
|
|
Attachment 18: Q_vs_Xf_K18.png
|
|
Fixed | e786s |
Fri Jun 28 08:54:50 2019 |
Freddy | RUN | General | Cryo-3He | run 74 |
Daniele Mengoni wrote: | screenshots run 74 attached
frequent error message on the FP DC Wi1 --> defqlt. The elog said so, card tripped, but spectra are still present .. puzzling |
Put the voltage back at 8h00 when i arrived. |
Fixed | e786s |
Fri Jun 28 08:57:21 2019 |
Freddy | CATS | General | Cryo-3He | CATS scaler not compatible with beam rate |
The CATS scaler si now around 100-120 kHz while the beam rate is still 40 kHz.
I checked the CATS signal and there is clearly noise who induce double logic signals. Not all of them are validated by FAG.
We should raise the threshold- call sebastien
9h32 : Stop beam to enter and raise the threshold. |
Attachment 1: ScalerCATSproblem.png
|
|
Fixed | e786s |
Fri Jun 28 09:56:59 2019 |
Bertrand, Valerian and Adrien | BEAM | General | N/A | Dipole stopped in the morning? |
Dipole restart at 10. Shoudl be checked with time stamp. |
Fixed | e786s |
Fri Jun 28 10:00:25 2019 |
OttoRun | RUN | General | Cryo-3He | Run75 |
*************************
Run : 75
*************************
Start at 2019-06-28 09:59:59.505010
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
CATS threshold raised
Stop at 2019-06-28 14:33:09.843668
Stop comment: |
Fixed | e786s |
Fri Jun 28 15:25:12 2019 |
OttoRun | RUN | General | Cryo-3He | Run76 |
*************************
Run : 76
*************************
Start at 2019-06-28 15:24:51.867946
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
beam back. Q pole issues still
Stop at 2019-06-28 16:55:27.258794
Stop comment: |
Fixed | e786s |
Fri Jun 28 18:34:35 2019 |
OttoRun | RUN | General | Cryo-3He | Run77 |
========================================
*************************
Run : 77
*************************
Start at 2019-06-28 18:34:22.873862
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
beam back. Q pole issues still
Stop at 2019-06-29 06:14:31.307098
Stop comment: |
Fixed | e786s |
Sat Jun 29 01:53:24 2019 |
OttoRun | RUN | General | Cryo-3He | Run77 |
OttoRun wrote: | *************************
Run : 77
*************************
Start at 2019-06-28 18:34:22.873862
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
beam back. Q pole issues still |
Beam is back, again, at 1.53, weird behavior of CATS |
Attachment 1: 77CATS.png
|
|
Fixed | e786s |
Sat Jun 29 05:41:12 2019 |
OttoRun | RUN | General | Cryo-3He | Run77 |
OttoRun wrote: |
OttoRun wrote: | *************************
Run : 77
*************************
Start at 2019-06-28 18:34:22.873862
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
beam back. Q pole issues still |
Beam is back, again, at 1.53, weird behavior of CATS |
|
Attachment 1: 78MM.png
|
|
Attachment 2: 80mmetof.png
|
|
Attachment 3: 79mg.png
|
|
Attachment 4: 81mmede.png
|
|
Attachment 5: 82mgetof.png
|
|
Attachment 6: tac.png
|
|
Attachment 7: corr.png
|
|
Attachment 8: cats.png
|
|
Fixed | e786s |
Sat Jun 29 05:56:40 2019 |
OttoRun | RUN | General | Cryo-3He | Run77 |
OttoRun wrote: |
OttoRun wrote: |
OttoRun wrote: | *************************
Run : 77
*************************
Start at 2019-06-28 18:34:22.873862
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
beam back. Q pole issues still |
Beam is back, again, at 1.53, weird behavior of CATS |
|
After beam is back we found 350Hz on vamos focal plane, with 20kHz current. After Brho scanning we found a Brho distribution going from 1Tm to 0.4Tm. Observation of gamma rays indicates no accumulation of radioactivity in the chamber with respect to previous runs. We conclude that we may have ice layers up to 500um in the target but very in-homogeneous since we also observe 1Tm Brho. To verify maybe increase target pressure to modify the structure of the ice. CATS is tripping continuously. No VACUUM changes observed. |
Fixed | e786s |
Sat Jun 29 06:18:06 2019 |
OttoRun | RUN | General | Cryo-3He | Run78 |
*************************
Run : 78
*************************
Start at 2019-06-29 06:17:46.891353
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
beam back. Q pole issues still
Stop at 2019-06-29 08:57:15.767428
Stop comment:
HV of Drift Chamber in VAMOS reduced from 670V to 660V in order to avoid saturation, this will keep like that in the following. |
Fixed | e786s |
Sat Jun 29 09:32:52 2019 |
OttoRun | RUN | General | Cryo-3He | Run79 |
*************************
Run : 79
*************************
Start at 2019-06-29 09:31:41.957308
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 800 mbar
We are filling the target to reach 1000 mbar
Stop at 2019-06-29 12:04:05.587989
Stop comment: |
Fixed | e786s |
Sat Jun 29 12:07:56 2019 |
OttoRun | RUN | General | Cryo-3He | Run80 |
*************************
Run : 80
*************************
Start at 2019-06-29 12:07:36.615014
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
Stop at 2019-06-29 13:03:26.602226
Stop comment: radioactive beam recovered |
Fixed | e786s |
Sat Jun 29 13:08:17 2019 |
OttoRun | RUN | General | Cryo-3He | Run81 |
*************************
Run : 81
*************************
Start at 2019-06-29 13:08:04.442155
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
Stop at 2019-06-29 19:22:32.016536
Stop comment: |
Fixed | e786s |
Sat Jun 29 20:31:21 2019 |
OttoRun | RUN | General | Cryo-3He | Run84 |
*************************
Run : 84
*************************
Start at 2019-06-29 20:30:36.534403
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
time calibration run |
Fixed | e786s |
Mon Jul 1 11:00:16 2019 |
OttoRun | RUN | General | Cryo-3He | Run85 |
*************************
Run : 85
*************************
Start at 2019-07-01 10:59:27.358229
target 700mb
Brho0=0.90 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
AGATA position +51-25 mm
TRIGGER :
- CMG
- M2
- VAMOS%1000
- CATS%1000
all X on MUVI disabled from trigger
all threshold of MUVI1 at 1 MeV to avoid as much as possible noise
LN filling problem solved !!!
pressure of the target slowly increasing about 820 mbar
We are filling the target to reach 1000 mbar
test cats1
time calibration run
New line added just for clarity!!!
Bye Bye!
Salut!
Ok! Ok!
Stop at 2019-07-01 13:14:06.453759
Stop comment: type your message here
Stop at 2019-07-01 13:14:06.826283
Stop comment: type your message here
Stop at 2019-07-01 13:14:07.927090
Stop comment: type your message here
Stop at 2019-07-01 13:14:08.499190
Stop comment: type your message here
Stop at 2019-07-01 13:14:08.824522
Stop comment: type your message here
Stop at 2019-07-01 13:20:31.953407
Stop comment: type your message here
Stop at 2019-07-01 13:52:26.358087
Stop comment: |