MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 15 of 132  Not logged in MUGAST
Fixed, e786s, Sun Jun 23 17:32:14 2019, OttoRun, RUN, General, Cryo-empty, Run24 
*************************
Run : 24
*************************

Start at 2019-06-23 17:32:11.627642

VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm

DC pressure 6 mbar
IC pressure 120 mbar

CATS2 inserted


TRIGGER
VAMOS %1000
MUGAST
MUS2
CATS 2%100

Stop at 2019-06-23 17:34:31.534959
Stop comment:
Fixed, e786s, Sun Jun 23 17:39:12 2019, OttoRun, RUN, General, Cryo-empty, Run25 
*************************
Run : 25
*************************

Start at 2019-06-23 17:39:09.199902

VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm

DC pressure 6 mbar
IC pressure 120 mbar

CATS2 inserted


TRIGGER
VAMOS %1000
MUGAST
MUS2
CATS 2%100

Stop at 2019-06-23 17:43:40.796527
Stop comment:
Fixed, e786s, Sun Jun 23 17:44:22 2019, OttoRun, RUN, General, Cryo-empty, Run26 
*************************
Run : 26
*************************

Start at 2019-06-23 17:44:18.480300

VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm

DC pressure 6 mbar
IC pressure 120 mbar

CATS2 inserted


TRIGGER
VAMOS %1000
MUGAST
MUS2

Stop at 2019-06-23 18:03:57.967230
Stop comment:

Stop at 2019-06-23 18:08:11.630931
Stop comment:
Fixed, e786s, Sun Jun 23 18:09:17 2019, OttoRun, RUN, General, Cryo-empty, Run28 
*************************
Run : 28
*************************

Start at 2019-06-23 18:09:16.019140

VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm

DC pressure 6 mbar
IC pressure 120 mbar

CATS2 inserted


TRIGGER
VAMOS %1000
MUGAST
MUS2

Stop at 2019-06-23 18:15:20.785307
Stop comment:
Fixed, e786s, Sun Jun 23 18:31:38 2019, OttoRun, RUN, General, Cryo-empty, Run31 
*************************
Run : 31
*************************

Start at 2019-06-23 18:31:37.368240

VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm

DC pressure 6 mbar
IC pressure 120 mbar

CATS2 inserted


TRIGGER
VAMOS %1000
MUGAST
MUS2

Stop at 2019-06-23 18:38:10.958169
Stop comment: End of RD fgor Pb of Coupling

Stop at 2019-06-23 19:39:33.051619
Stop comment:

Stop at 2019-06-23 19:39:39.833725
Stop comment: type your message here

Stop at 2019-06-23 20:32:23.587613
Stop comment: testing the run control
Fixed, e786s, Sun Jun 23 20:58:04 2019, OttoRun, RUN, General, Cryo-empty, Run41 
*************************
Run : 41
*************************

Start at 2019-06-23 20:57:51.947211

VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm

DC pressure 6 mbar
IC pressure 120 mbar

CATS2 inserted


Test Coupling With AGATA
TRIGGER
VAMOS %100
Fixed, e786s, Sun Jun 23 21:15:20 2019, OttoRun, RUN, General, Cryo-empty, Run42 
*************************
Run : 42
*************************

Start at 2019-06-23 21:15:14.348251

VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm

DC pressure 6 mbar
IC pressure 120 mbar

CATS2 inserted


Test Coupling With AGATA
TRIGGER
VAMOS %100
Fixed, e786s, Sun Jun 23 21:21:09 2019, OttoRun, RUN, General, Cryo-empty, Run45 
*************************
Run : 45
*************************

Start at 2019-06-23 21:21:04.748199

VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm

DC pressure 6 mbar
IC pressure 120 mbar

CATS2 inserted


Test Coupling With AGATA
TRIGGER
VAMOS %100

Stop at 2019-06-23 21:39:52.572827
Stop comment:
Fixed, e786s, Sun Jun 23 21:43:45 2019, OttoRun, RUN, General, Cryo-3He, Run46 
*************************
Run : 46
*************************

Start at 2019-06-23 21:42:22.018646

Target Making (260mb at start) with 2.5 10*4
Brho0=1.05 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

Coupled with AGATA with loosy LTS

TRIGGER :
- VAMOS %100
- MM
- MG

Stop at 2019-06-23 22:33:28.947041
Stop comment:
Fixed, e786s, Sun Jun 23 22:54:08 2019, OttoRun, RUN, General, Cryo-3He, Run47 
*************************
Run : 47
*************************

Start at 2019-06-23 22:53:38.158434

Target Making (xxxx at start) with 2.5 10*4
Brho0=1.05 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

Coupled with AGATA after attempt to fix AGAVA TS

TRIGGER :
- VAMOS %100
- MM
- MG

Stop at 2019-06-23 22:57:59.635528
Stop comment:

Stop at 2019-06-23 23:33:23.021160
Stop comment: type your message here
Fixed, e786s, Sun Jun 23 23:36:18 2019, OttoRun (Louis edit), RUN, General, Cryo-3He, Run49 
*************************
Run : 49
*************************

Start at 2019-06-23 23:36:11.373234

Target Making (xxxx at start) with 2.5 10*4
Brho0=1.05 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

Coupled with AGATA after attempt to fix AGAVA TS

TRIGGER :
- VAMOS %100
- MM
- MG

Beam stopped at 5h27 for neutron excess in a restricted area after CIME. until...

Stop at 2019-06-24 09:25:27.526617
Stop comment: waiting for the beam
Fixed, e786s, Mon Jun 24 01:52:00 2019, Louis, OFFLINE, Software, Cryo-3He, Procedure to convert and calibrate runs 

Here is the updated procedure to convert a run, with VAMOS data.


Every 4Go there will be a file change, to see if there is a file change do :

ls -ltrh /data/mugastX/e786s/acquisition/run/


convert the last 4Go file and add it to the chain using the following step:

Step O: Take your favorite ortholinear keyboard (optional)

Step 1: Login the VAMOS environment and convert the run :

Open a terminal from one of the mugast computer:

Type: source $HOME/GoToVamosAna
Type: MyVAna -d2Ar -f /data/mugastX/e786s/acquisition/run/run_$$$$-DD-MM-YY.HHhMMmSSs /data/mugastX/e786s/acquisition/RootA/r$$$$_000a.root

OR

Type: MyVAna -d2Ar -f /data/mugastX/e786s/acquisition/run/run_$$$$-DD-MM-YY.HHhMMmSSs.N /data/mugastX/e786s/acquisition/RootA/r$$$$_00Na.root

(If you encounter the error on Brho "Could not find the BrhoRef for the run <RunNr> ", Update the ./Calibs/ListBrho.dat file with relevant Brho for RunNr)

Step 2: Analyse the file using the npanalysis program:

Type: exit (<-this exit the environment of VAMOS)
Type: lpcgrit (<-this load the analysis environment )
Type: npp MUGAST
Type: edit the exe.sh to treat releverant run. command should be: npanalysis -D mugast.detector -C Calibration.txt -E ./Reaction/46Ar3Hed.reaction -T ./offline/root_e786svamos/r$$$$_00Na.root AD -O run_$$$$_N.root

(This could be used with any file, either from Offline conversion, or the VAMOS Analysis conversion or the Merged Tree from AGATA)

The run will be created in the NPOutputs folder
Fixed, e786s, Mon Jun 24 03:08:49 2019, Marlène, RUN, General, Cryo-3He, Brho issue Brho_vamos.png
We observe a change in the Brho of VAMOS : the charged states are divided in 2 !!!

Édit: it is now understood as ice water cracking on the upstream of the target.
Fixed, e786s, Mon Jun 24 03:52:11 2019, Marlène Matthieu, RUN, General, Cryo-3He, 3He target filled with 700 mb 
The 3He cryo target is filled with a pressure of 700 mb
The temperature on the target is 5.98K

The LHe dewar has been changed at 1 a.m.
Fixed, e786s, Mon Jun 24 05:27:21 2019, Louis, OTHER, General, Cryo-3He, Beam interuption 
Beam stopped due to a neutron excess in a restricted area. Have to call the SPR. At least 1h of interruption..
Fixed, e786s, Mon Jun 24 06:14:02 2019, Louis, OFFLINE, General, Cryo-3He, Offline analysis 46Ar(3He,d)47K for run 49 Kine.pngdEToFMG.png
Energy loss vs. Time of Flight identification has been performed in mugast. On can notice some calibration trouble in energy and time. Big shift of the deToF bananas are seen from one telescope to an other. Furthermore, one can distinguish proton and deuteron in MG1, 3 and 4 but it's it's very difficult to conclude for 5,7 and 11.

From those plots, deuteron has been selected. Adding a cut on the center of the CATS profile and on the Brho in vamos, energy and angle in the laboratory has been computed. And then the excitation energy. Nothing clear for the moment...

a macro "Get46ArHe3d.C" which apply cuts and generate a new tree with only gated event is written in:
/home/mugast/analysis/nptool/Projects/MUGAST/macros/e786s
the generated tree "46ArHe3d.root" contains only event which passed cuts.

cheers
Fixed, e786s, Mon Jun 24 09:45:59 2019, OttoRun, RUN, General, Cryo-3He, Run48 
*************************
Run : 48
*************************

Start at 2019-06-23 23:31:16.366471

Target Making (xxxx at start) with 2.5 10*4
Brho0=1.05 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

Coupled with AGATA after attempt to fix AGAVA TS

TRIGGER :
- VAMOS %100
- MM
- MG
Fixed, e786s, Mon Jun 24 09:55:06 2019, OttoRun, RUN, General, Cryo-3He, Run50 
*************************
Run : 50
*************************

Start at 2019-06-24 09:47:38.321557

Target Making (xxxx at start) with 2.5 10*4
Brho0=1.05 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

Coupled with AGATA after attempt to fix AGAVA TS

TRIGGER :
- VAMOS %100
- MM
- MG

Stop at 2019-06-24 12:25:33.653748
Stop comment: type your message here
Fixed, e786s, Mon Jun 24 12:06:17 2019, mugast, OFFLINE, General, N/A, Beam energy loss Kinepp.png
Caculation with LISE++
Beam initial: 9.96 MeV/u
CATS 2 : 9.79
15 um ice water: 9.39
3.8 um Havar: 8.83
2.2 mm 3He (mid target): 8.24
2.2 mm 3He (full target): 7.61
3.8 um Havar : 6.99
15 um ice water: 6.50

with this we saw correctly both pp and pp' in MUST2:
Fixed, e786s, Mon Jun 24 13:06:50 2019, OttoRun, RUN, General, Cryo-3He, Run52 
*************************
Run : 52
*************************

Start at 2019-06-24 13:05:57.789780

Target Making (xxxx at start) with 2.5 10*4
Brho0=1.05 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
******TEST OF TARGET THICKNESS*****

Coupled with AGATA after attempt to fix AGAVA TS

TRIGGER :
- VAMOS %30
- MM
- MG

Stop at 2019-06-24 15:37:24.149482
Stop comment: stopped to move AGATA in a more compact position and for CATS