Fixed, e786s, Wed Jun 19 13:11:57 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 240
- MUVI: MUVI2
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4 |
Fixed, e786s, Wed Jun 19 13:36:41 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 241
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4 |
Fixed, e786s, Wed Jun 19 14:02:04 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 242
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4 |
Fixed, e786s, Fri Jun 21 15:15:08 2019, OttoTime, OTHER, Software, N/A, TimeCalibrationSuccessful 
|
OttoTime wrote: | *** Run Time Calibrator FSC ***
- Run: 242
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4 |
Updated time calibration for Mugast and MUST2. |
Fixed, e786s, Sun Jun 23 08:29:14 2019, OttoRun, RUN, General, Cryo-empty, Run10
|
*************************
Run : 10
*************************
Start at 2019-06-23 08:03:31.361779
Firt run, VAMOS tunning
Brho0=1.16 Tm
DC pressure 5.8 mbar
IC pressure 120 mbar
Stop at 2019-06-23 10:08:04.932948
Stop comment: Entering to Change IC 5-6 Preamps |
Fixed, e786s, Sun Jun 23 09:06:29 2019, Daniele M, VAMOS, General, N/A, VAMOS SETTINGS
|
attached the energy measured in CIME and the calculated VAMOS settings |
Fixed, e786s, Sun Jun 23 10:08:07 2019, OttoRun, RUN, General, Cryo-empty, Run11
|
*************************
Run : 11
*************************
Start at 2019-06-23 08:29:17.562468
VAMOS tunning
Brho0=1.16 Tm
DC pressure 5.8 mbar
IC pressure 120 mbar |
Fixed, e786s, Sun Jun 23 12:01:52 2019, OttoRun, RUN, General, Cryo-empty, Run12
|
*************************
Run : 12
*************************
Start at 2019-06-23 12:01:18.221065
VAMOS tunning Continued
After Fixing the IC preamp issue
Brho0=1.16 Tm
DC pressure 5.8 mbar
IC pressure 120 mbar
VAMOS % 100
Stop at 2019-06-23 12:22:43.905554
Stop comment: |
Fixed, e786s, Sun Jun 23 12:23:08 2019, OttoRun, RUN, General, Cryo-empty, Run13
|
*************************
Run : 13
*************************
Start at 2019-06-23 12:22:47.250526
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.16 Tm
DC pressure 6 mbar
IC pressure 120 mbar
VAMOS % 100
Stop at 2019-06-23 13:02:45.652212
Stop comment: Stopping to insert CATS2 |
Fixed, e786s, Sun Jun 23 13:14:58 2019, OttoRun, RUN, General, Cryo-empty, Run14
|
*************************
Run : 14
*************************
Start at 2019-06-23 13:14:46.494154
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.16 Tm
DC pressure 6 mbar
IC pressure 120 mbar
VAMOS % 100
CATS2 inserted
Stop at 2019-06-23 13:27:45.448777
Stop comment: Entering to fix CATS2 signal on VAMOS Side |
Fixed, e786s, Sun Jun 23 13:37:13 2019, OttoRun, RUN, General, Cryo-empty, Run15
|
*************************
Run : 15
*************************
Start at 2019-06-23 13:36:44.035671
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.16 Tm
DC pressure 6 mbar
IC pressure 120 mbar
VAMOS % 100
CATS2 inserted
After trying to solve CATS2 mixing in VAMOS |
Fixed, e786s, Sun Jun 23 14:02:26 2019, OttoRun, RUN, General, Cryo-empty, Run16
|
*************************
Run : 16
*************************
Start at 2019-06-23 13:55:39.339279
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.16 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
TRIGGER
VAMOS %1000
MUGAST
MUS2
Stop at 2019-06-23 14:02:44.471982
Stop comment: |
Fixed, e786s, Sun Jun 23 14:09:20 2019, OttoRun (edit by Louis), RUN, General, Cryo-empty, Run17 6x
|
*************************
Run : 17
*************************
Start at 2019-06-23 14:07:50.801211
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.09 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
TRIGGER
VAMOS %1000
MUGAST
MUS2
Stop at 2019-06-23 15:39:57.322868
Stop comment: Stopping For Brho scan |
Fixed, e786s, Sun Jun 23 14:37:43 2019, Freddy, Franco and Louis, OTHER, Hardware, , Temperature error on +2.5v/t3
|
There is a temperature error on the +2.5 V for MUST2 Telescope. It created error message due to hv_monitor but it does not shutdown the voltage.
We modified the code in hv_monitor to not display popup message and elog message if this channel is concerned. |
Fixed, e786s, Sun Jun 23 15:47:36 2019, OttoRun, RUN, General, Cryo-empty, Run18
|
*************************
Run : 18
*************************
Start at 2019-06-23 15:47:26.907823
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=0.95 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
TRIGGER
VAMOS %1000
MUGAST
MUS2
Stop at 2019-06-23 16:01:59.558020
Stop comment: Stooping Brho=0.95 Tm |
Fixed, e786s, Sun Jun 23 16:20:18 2019, OttoRun, RUN, General, Cryo-empty, Run19
|
*************************
Run : 19
*************************
Start at 2019-06-23 16:19:58.878324
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.2 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
TRIGGER
VAMOS %1000
MUGAST
MUS2
CATS 1?2 ?%
Stop at 2019-06-23 16:30:15.785443
Stop comment: CATS1 is nor CATS2 ! |
Fixed, e786s, Sun Jun 23 16:30:33 2019, OttoRun, RUN, General, Cryo-empty, Run20
|
*************************
Run : 20
*************************
Start at 2019-06-23 16:30:25.175482
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.2 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
TRIGGER
VAMOS %1000
MUGAST
MUS2
CATS 2%30000
Stop at 2019-06-23 16:43:43.394596
Stop comment: |
Fixed, e786s, Sun Jun 23 16:57:04 2019, OttoRun, RUN, General, Cryo-empty, Run21
|
*************************
Run : 21
*************************
Start at 2019-06-23 16:56:47.677860
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.2 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
TRIGGER
VAMOS %1000
MUGAST
MUS2
CATS 2%100
Changing delays in the MVI Stop +250ns
Stop at 2019-06-23 17:14:45.149988
Stop comment: |
Fixed, e786s, Sun Jun 23 17:23:23 2019, OttoRun, RUN, General, Cryo-empty, Run22
|
*************************
Run : 22
*************************
Start at 2019-06-23 17:23:10.139349
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
TRIGGER
VAMOS %1000
MUGAST
MUS2
CATS 2%100
Stop at 2019-06-23 17:26:13.500437
Stop comment: |
Fixed, e786s, Sun Jun 23 17:28:07 2019, OttoRun, RUN, General, Cryo-empty, Run23
|
*************************
Run : 23
*************************
Start at 2019-06-23 17:28:04.413096
VAMOS tunning Continued with 2.5 10*4
After Fixing the IC preamp issue
Brho0=1.05 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted
TRIGGER
VAMOS %1000
MUGAST
MUS2
CATS 2%100
Stop at 2019-06-23 17:31:20.138870
Stop comment: |
|