Fixed, e793s, Tue Mar 10 18:46:13 2020, Franco & Marlène, GRIT, Hardware, , Changes in MUGAST 
|
- MG6 (FZ) is disconnected.
- MG7 (500um) is dismounted and MG8 (375um) is replacing it.
- The Y kapton of the annular has been changed.
|
Fixed, e793s, Thu Mar 12 15:48:58 2020, Franco&Marlène, GRIT, General, , Summary and TO DO list 12/03/2020
|
What remains to be done
- Do the time calibration of all boards (time calibrator has to be connected)
. When checking the pulser on all boards we saw that MG5 has no triggers on Y and MG9 does not see the pulser (neither X or Y). So we will not |
, , Tue May 19 12:23:57 2020, mugast, ONLINE, , ,
|
|
Fixed, e793s, Fri Mar 5 16:16:28 2021, mugast, DAQ, Software, , Pedestals for E793S 12x
|
Pedestal alignment was performed for Energy qnd Time for all cards with cooling at 0°.
The values are attached here and saved in : cd ganacq_manip/mugast/das-save/pedestal-save/pedestal_5march2021_15h54/ |
Fixed, e793s, Wed Mar 10 15:15:44 2021, Charlie, OTHER, General, , 48Ti Kinematics (additional)  
|
Supplementary to Adrien's kinematic calculations of 47Ti(d,p)48Ti, we have found a paper suggesting that by far the most strongly populated state in 48Ti
is at 5.65 MeV. There is also a doublet of strong states at around 4.4 MeV, and two more strongly populated states at 6.06 and 6.33 MeV.
|
Fixed, e793s, Wed Mar 10 18:22:01 2021, Taras, Nishu, Chloe, RUN, General, , status screenshot
|
|
Ongoing, e793s, Wed Mar 10 21:09:25 2021, mugast (Adrien, Nigel et co), BEAM, General, , Primary beam issues
|
The secondary beam intensity has been fluctuating around 4 - 5 x 10**5 Hz most of the evening. 15 mins ago it was realised that it had dropped off to
only 1 x 10**5 Hz. As suspected, PCP confirmed that primary beam intensity has dropped off. They are investigating ...
|
Pending, e793s, Wed Mar 10 23:37:23 2021, Nishu, Chloe, Taras, RUN, General, , FAG value increased
|
Around 11:30 pm FAg value increased from usual 60-70 units to 140 units. It is suspected that MUGAST increased the trigger rate. |
Fixed, e793s, Fri Mar 12 10:07:29 2021, mugast, MECH, Hardware, , Leak
|
https://www.hometree.co.uk/energy-advice/home-cover/common-water-leaks-and-how-to-fix-them.html |
Ongoing, e793s, Fri Mar 12 12:58:10 2021, Emmanuel C, OFFLINE, General, , Gamma Gamma Analysis 7x
|
|
Fixed, e793s, Sat Mar 13 10:14:16 2021, Lynda, Laetitia, Chloe, VAMOS, General, , Vamos tripped @ 10:10 & fixed
|
Vamos tripped around 10:10. we switched back 3 HV on
Online spectra reset to check |
Fixed, e793s, Sat Mar 13 11:16:38 2021, Lynda, Laetitia, Chloe, BEAM, General, , beam lost and back
|
we loose the beam around 11:12, it should be back in few minutes according to pcp.
11:18: the beam is back (3.5E5 pps) |
Fixed, e793s, Sat Mar 13 18:37:01 2021, Emmanuel C, OFFLINE, General, , Efficiency gamma AGATA
|
TF1 *fit_1 = new TF1("fit_1","TMath::Exp([0]+[1]*TMath::Log(x)+[2]*pow(TMath::Log(x),2.0)+[3]*pow(TMath::Log(x),3.0)+[4]*pow(TMath::Log(x),4.0))",100,5000);
//NRJ traite en keV et efficiency en %
p0 -7.84071e+00
|
Ongoing, e793s, Wed Mar 17 15:17:39 2021, Emmanuel C, OFFLINE, General, , New gamma gamma analysis
|
The level scheme is based on coherent check of
1- gamma gamma
2- gamma gated by Ex
|
Fixed, e793s, Thu Mar 18 16:25:56 2021, Emmanuel C, OFFLINE, General, , Efficiency gamma AGATA --- real measurement run70
|
[quote="Emmanuel C"] TF1 *fit_1 = new TF1("fit_1","TMath::Exp([0]+[1]*TMath::Log(x)+[2]*pow(TMath::Log(x),2.0)+[3]*pow(TMath::Log(x),3.0)+[4]*pow(TMath::Log(x),4.0))",10,5000);
//NRJ traite en keV et efficiency en %
|
Fixed, e793s, Tue Mar 23 10:22:48 2021, Emmanuel C, OFFLINE, General, , Efficiency gamma AGATA --- real measurement run70
|
I have been working on the high energy response.
The point is that we do not have source measurement beyond 2 MeV to constrain the fit.
|
|