Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e775s |
Thu Feb 27 09:54:17 2020 |
Nicolas, Sylvain, Antoine, Adrien | RUN | General | | run 139 |
Start at 09h50 (Feb. 27th)
Stop at
Beam: 19O
Intensity: 3e5 pps
Target; CD2 + Au #2 |
Fixed | e775s |
Thu Feb 27 09:56:19 2020 |
Nicolas, Sylvain, Antoine, Adrien | RUN | General | | run 139 - analysis |
Nicolas, Sylvain, Antoine, Adrien wrote: | Start at 09h50 (Feb. 27th)
Stop at
Beam: 19O
Intensity: 3e5 pps
Target; CD2 + Au #2 |
|
Fixed | e775s |
Thu Feb 27 09:56:39 2020 |
Nicolas, Sylvain, Antoine, Adrien | RUN | General | | run 139 - Beam intensity time evolution |
Nicolas, Sylvain, Antoine, Adrien wrote: | Start at 09h50 (Feb. 27th)
Stop at
Beam: 19O
Intensity: 3e5 pps
Target; CD2 + Au #2 |
|
Fixed | e775s |
Thu Feb 27 10:03:03 2020 |
Nicolas, Sylvain, Antoine, Adrien | RUN | General | | run 139 - minutes of what happened during the run |
Here is a brief summary of what happened over the course of the run:
From beginning of run to 12 pm (February 27th)
Nicolas, Sylvain, Antoine, Adrien wrote: | Start at 09h50 (Feb. 27th)
Stop at
Beam: 19O
Intensity: 3e5 pps
Target; CD2 + Au #2 |
|
Fixed | e775s |
Thu Feb 27 11:51:34 2020 |
Nicolas Sylvain Marlène | RUN | General | | run 139 |
Start at 09h51 (Feb. 27th)
Stop at 11h22 (Feb. 27th)
Beam: 19O
Intensity: 3e5 pps
Target; CD2 + Au #2 |
Fixed | e775s |
Thu Feb 27 11:53:34 2020 |
mugast | RUN | General | | run 140 |
Start at 11h41 (Feb. 27th)
Stop at (Feb. 27th)
Beam: 19O
Intensity: 4e5 pps
Target; CD2 (350 ug/cm2, NO gold) #3 |
Fixed | e775s |
Thu Feb 27 12:35:39 2020 |
Marlène Nicolas | GRIT | General | | RUN128-137_138 analysis |
Kinematic lines for the full statistics up to now
States above E*>7 MeV are cut in the angles >140 because of energy threshold. |
Attachment 1: Elab_Thetalab_RUN128_137_138.png
|
|
Attachment 2: ExEg_RUN128_137_139.png
|
|
Attachment 3: Ex_RUN128_137_138.png
|
|
Pinned | e775s |
Thu Feb 27 12:44:37 2020 |
Nicolas | OFFLINE | Software | | How to produce control spectra |
In /home/mugast/analysis/nptool/Projects/MUGAST/e775s directory there is the Control.C macro which draws: Ex, Ex vs Eg and Elab vs thetalab for each run (run number must be given in argument) or for chained runs (argument must be 0) |
Fixed | e775s |
Thu Feb 27 15:51:03 2020 |
mugast | RUN | General | | RUN 140 |
Target CD2 thin target
Beam intensity ~ 5e+5 pps
to check the gammas from 20O |
Fixed | |
Thu Feb 27 15:54:09 2020 |
Marlène | RUN | General | | RUN 141 junk (problem at start) |
|
Fixed | |
Thu Feb 27 15:56:09 2020 |
Marlène | RUN | General | | RUN 142 AGATA- 143 VAMOS-MUGAST |
RUN142 on AGATA and RUN143 on MUGAST/VAMOS
target CD2 (350ug/cm2)
Trigger MUGAST
Beam intensity : 5e+5pps
!!!! there is a shift in the run number on AGATA with respect to VAMOS/MUGAST |
Fixed | |
Thu Feb 27 16:25:45 2020 |
Marlène | RUN | General | | RUN 142-143 screenshots |
Marlène wrote: | RUN142 on AGATA and RUN143 on MUGAST/VAMOS
target CD2 (350ug/cm2)
Trigger MUGAST
Beam intensity : 5e+5pps
!!!! there is a shift in the run number on AGATA with respect to VAMOS/MUGAST |
|
Attachment 1: RUN143_ElabThetaLab.png
|
|
Attachment 2: RUN143_impact.png
|
|
Attachment 3: RUN143_tac.png
|
|
Attachment 4: RUN143_tof.png
|
|
Fixed | |
Thu Feb 27 16:30:53 2020 |
Marlène | RUN | General | | RUN 142 -143 preliminary analysis |
Marlène wrote: |
Marlène wrote: | RUN142 on AGATA and RUN143 on MUGAST/VAMOS
target CD2 (350ug/cm2)
Trigger MUGAST
Beam intensity : 5e+5pps
!!!! there is a shift in the run number on AGATA with respect to VAMOS/MUGAST |
|
|
Attachment 1: RUN143_ana_Elab_Thetalab.png
|
|
Attachment 2: RUN143_ana_Ex_Eg.png
|
|
Attachment 3: RUN143_ana_Ex.png
|
|
Pinned | e775s |
Thu Feb 27 16:35:26 2020 |
Nicolas | OFFLINE | Software | | How to produce control spectra |
Nicolas wrote: | In /home/mugast/analysis/nptool/Projects/MUGAST/e775s directory there is the Control.C macro which draws: Ex, Ex vs Eg and Elab vs thetalab for each run (run number must be given in argument) or for chained runs (argument must be 0) |
A new file has been created to look into the CD2 target runs : Control_CD2.C |
Fixed | e775s |
Thu Feb 27 16:36:25 2020 |
Nicolas Sylvain Marlène | RUN | General | | run 139 |
Nicolas Sylvain Marlène wrote: | Start at 09h51 (Feb. 27th)
Stop at 11h22 (Feb. 27th)
Beam: 19O
Intensity: 3e5 pps
Target; CD2 + Au #2 |
temperature on MUFEE was checked to be between 0 and 12 degress depending on the boards.
The current of the detectors are stable. |
Fixed | |
Fri Feb 28 11:20:22 2020 |
Marlène | GRIT | General | | RUN 150 |
RUN 150
target CD2 300 ug/cm2
Beam intensity 4e+5pps
Note that there is no 144,145,146,147, 148 ans 149 runs |
Fixed | e775s |
Fri Feb 28 11:21:31 2020 |
Marlène | RUN | General | | RUN 151 |
RUN 151
Change of target now : CD2+AU #2
Beam intensity : 4e+5pps |
| e775s |
Fri Feb 28 13:58:31 2020 |
Marlène | | | | |
|
Fixed | e775s |
Fri Feb 28 14:00:08 2020 |
Marlène | RUN | General | | RUN 151 beam stop |
Marlène wrote: | RUN 151
Change of target now : CD2+AU #2
Beam intensity : 4e+5pps |
beam stopped due to unstable equipment in CSS1.
expected duration : 15 min |
Fixed | e775s |
Sun Mar 1 17:04:43 2020 |
Marlène François | RUN | General | | Preliminary analysis of runs from 128 up to now (169) |
Preliminary analysis with all stat up to now. |
Attachment 1: Ex_allruns_128-169.png
|
|
Attachment 2: Eg_condMG_stat_allruns_128-169.png
|
|
Attachment 3: Eg_condMG_allruns_128-169.png
|
|
Attachment 4: Ex_allruns_128-169.png
|
|
Attachment 5: thetaLab_ELab_allruns_128-169.png
|
|
Attachment 6: Ex_Eg_projY_allruns_128-169.png
|
|