Pinnede786s Wed Apr 10 13:30:48 2019 Valerian, Adrien and Antoine (edit by Louis)OFFLINESoftwareN/AHow to perform analysis for e786s

Here is the updated procedure to convert a run, with VAMOS data and add those data to the Kinematic plot.


Every 4Go there will be a file change, to see if there is a file change do :

  • ls -ltrh /data/mugastX/e786s/acquisition/run/

convert the last 4Go file and add it to the chain using the following step:

Step O: Take your favorite ortholinear keyboard (optional)

Step 1: Login the VAMOS environment and convert the run :

Open a terminal from one of the mugast computer:
  • Type: source $HOME/GoToVamosAna
  • Type: MyVAna -d2Ar -f /data/mugastX/e786s/acquisition/run/run_$$$$-DD-MM-YY.HHhMMmSSs /data/mugastX/e786s/acquisition/RootA/r$$$$_000a.root
OR
  • Type: MyVAna -d2Ar -f /data/mugastX/e786s/acquisition/run/run_$$$$-DD-MM-YY.HHhMMmSSs.N /data/mugastX/e786s/acquisition/RootA/r$$$$_00Na.root
(If you encounter the error on Brho "Could not find the BrhoRef for the run <RunNr> ", Update the ./Calibs/ListBrho.dat file with relevant Brho for RunNr)

Step 2: Analyse the file using the npanalysis program:
  • Type: exit (<-this exit the environment of VAMOS)
  • Type: lpcgrit (<-this load the analysis environment )
  • Type: npp MUGAST
  • Type: edit the exe.sh to treat releverant run. command should be: npanalysis -D mugast.detector -C Calibration.txt -E ./Reaction/46Ar3Hed.reaction -T ./offline/root_e786svamos/r$$$$_00Na.root AD -O run_$$$$_N.root

(This could be used with any file, either from Offline conversion, or the VAMOS Analysis conversion or the Merged Tree from AGATA)

The run will be created in the NPOutputs folder
Fixed  Mon Jun 24 14:14:17 2019 Valerian, Adrien - DudouetOFFLINEGeneral p,p' analysis of run49
Attachment 1: Screenshot_from_2019-06-24_14-09-39.png
Screenshot_from_2019-06-24_14-09-39.png
Attachment 2: Kine46Arpp.png
Kine46Arpp.png
Attachment 3: Gamma46Arpp.png
Gamma46Arpp.png
Fixede744s Mon Apr 15 12:15:22 2019 Valerian and SylvainOFFLINESoftwareCH2Kinematic line 2p
Attachment 1: ELabThetaLab_new.png
ELabThetaLab_new.png
Attachment 2: Ecm2p_new.png
Ecm2p_new.png
Fixede744s Thu Apr 11 16:07:59 2019 Valerian and LouisOFFLINESoftwareCH2HF resolution
Using the value of the HF=83,4ns. We can obtain the calibrated plot of T_CATS2_HF which is joined and gives us roughly a 2-3 ns resolution for the HF
Attachment 1: T_CATS2_HFns.png
T_CATS2_HFns.png
FixedTEST Wed Apr 3 15:49:02 2019 Valerian and Jenn, Chloé and François OTHERHardwareN/AElectronic scheme of VAMOS and MUGAST
Edit : 4/04/19 Valerian and Jenn small correction of MUGAST scheme
Attachment 1: VAMOS_electronic_scheme.pdf
VAMOS_electronic_scheme.pdf VAMOS_electronic_scheme.pdf
Attachment 2: VAMOS_electronic_scheme.pptx
Attachment 3: MUGAST_Electronic_scheme_v2.pptx
Attachment 4: MUGAST_Electronic_scheme_v3.pdf
MUGAST_Electronic_scheme_v3.pdf MUGAST_Electronic_scheme_v3.pdf MUGAST_Electronic_scheme_v3.pdf MUGAST_Electronic_scheme_v3.pdf MUGAST_Electronic_scheme_v3.pdf MUGAST_Electronic_scheme_v3.pdf MUGAST_Electronic_scheme_v3.pdf MUGAST_Electronic_scheme_v3.pdf
Attachment 5: MUGAST_Electronic_scheme_v3.pptx
FixedTEST Mon Mar 4 12:28:26 2019 Valerian and IulianMUST2General3-alphaNo DECS and acq error run 47-48-49. Das Saved after problem fixed
Fixed. Solution:
1) CENTRUM not configured on GENTRUM Master
2) GMT matrix on GMT3 (2nd slave) was all 0

DAS saved after solution found
Attachment 1: run49_error_acq.png
run49_error_acq.png
Fixede744s Sun Apr 14 12:11:52 2019 Valerian and IulianOFFLINESoftwareCH2VERY VERY preliminary results Gamma-p
Around 8-10 events are found in the good energy vs Brho region and Si_T vs Si_E region for the gamma emission.

Joined are :

- the cut done for Energy vs Brho
- the "good" Events plotted on the Si_E vs Si_T spectra for each telescope.


one can see that most events are in, or close to the punch through but some of them ~8-10 are not -> very good candidates for proton after gamma emission
Attachment 1: EPCM_Brho_gamma.png
EPCM_Brho_gamma.png
Attachment 2: PossiblePafterGamma_ToF.png
PossiblePafterGamma_ToF.png
Attachment 3: Epcm_gamma.png
Epcm_gamma.png
Fixede744s Thu Apr 11 18:20:27 2019 Valerian and DiegoOFFLINESoftwareCH2Timing issue between vamos and mugast
A cut is seen on the TAC between MUGAST and the focal plane multiwire of VAMOS when one select XF or DC0_Y>-1500


Edit: This must be a reconstruction problem as it is not seen in the Raw files (using DC0_X for example)

Edit: This is not only a reconstruction problem as the cut appear again if one select DC0_Y

Edit: We changed VAMOS FAG validation window from 500ns to 800ns
Attachment 1: T_MUGAST_FPMW.png
T_MUGAST_FPMW.png
Attachment 2: T_MUGAST_FPMW1.png
T_MUGAST_FPMW1.png
Fixede744s Fri Apr 12 22:44:43 2019 Valerian and DiegoOFFLINESoftwareCH213N measured in Vamos do correspond to protons events in MUST2
Doing a cut on M vs M/Q corresponding to 13N one can see that most of the events do correspond to protons events in MUST2!!!
Attachment 1: Vamos13N_and_MUST2protons.png
Vamos13N_and_MUST2protons.png
Fixede744s Wed Apr 17 13:48:25 2019 Valerian and DiegoRUNSoftwareCH2New Dalitz plot with good angles in vamos
The previous Dalitz plot was wrong as I was using the angle from vamos as polar angles.
Now that it is corrected we see that this decay seems sequential.
Attachment 1: DalitzGoodAngle.png
DalitzGoodAngle.png
FixedTEST Wed Mar 27 11:06:33 2019 Valerian and CyrilGRITHardware3-alphaEvolution of resolution with temperature
For the mugast telescope, changing the temperature from 13deg to minus 4deg doesn't seem to have an impact as strong as for the MUST2 telescopes.
Still, the resolution improve with a lower temperature, but the improvement is of only 0.1 channel... (See joined screenshots)
Attachment 1: MG4_13_deg.png
MG4_13_deg.png
Attachment 2: MG4_minus_4_deg.png
MG4_minus_4_deg.png
FixedTEST Thu Mar 21 13:28:06 2019 Valerian and AdrienDAQSoftwareN/AFirst fully functionnal time calibration run on X and Y of MG1
Our program is able to perform the time calibration of our detector for both X and Y, see picture attached.
Attachment 1: CALIMEROY1.png
CALIMEROY1.png
Attachment 2: FIRST_TIMECALIBRATION_WITHOUT_CALIMERO.png
FIRST_TIMECALIBRATION_WITHOUT_CALIMERO.png
Fixede786s Mon Jun 24 16:50:48 2019 Valerian and AdrienOFFLINESoftwareCryo-3He3He-d kinematics
To plot those kinematics, there is a macros called kine.cxx

The first plot correspond to the Silicon energy in MUGAST corrected for energy loss (some improvement might be needed)
Second plot is the same but without energy loss corrections (Raw silicon energy)
Third plot is the excitation energy of 47K
Attachment 1: Kine47K.png
Kine47K.png
Fixede786s Wed Jun 26 09:56:17 2019 Valerian and AdrienRUNGeneralCryo-3HeIdentification E-TOF MUGAST
Light particle ID in MUGAST (no S1 because shitty time).

The red cut is on what we believe is deuterium.

The containt of the cut stop at 8MeV when gating on vamos.
Attachment 1: ETOF_d.pdf
ETOF_d.pdf
Attachment 2: ETOF_d_vamos.pdf
ETOF_d_vamos.pdf
Fixede775s Wed Mar 4 11:06:49 2020 Valerian IreneOFFLINEGeneralN/ASecond 2+
Current comparison between the CD2 target and CD2 + Au target.
Attachment 1: Second2PlusCurrentStat.pdf
Second2PlusCurrentStat.pdf
Fixede744s Wed Apr 17 07:04:24 2019 Valerian (Mariluz was the one in charge of AGATA)AGATASoftwareCH2Cristal 4A stopped
Cristal 4A was stopped during the night, see AGATA logbook for more details.
Fixede768s Wed Jul 31 14:32:53 2019 Valerian & CoRUNGeneralN/ABeam intensity dropped
unstable beam since 15min... Intensity dropped from 8e6 to 1e5

Edit : Beam is back at 8 10^6 pps
Attachment 1: index.jpg
index.jpg
Attachment 2: scalers_run160_11.png
scalers_run160_11.png
Fixede786s Tue Jun 25 08:23:58 2019 Valerian BEAMGeneralN/ABeam status
Currently there is no beam since 22h-> Thunder + no more 48Ca sample. The sample was out during the night.

The "sourcier" on-call arrived at 8h15. By talking to people in shift at the PCP they told me that more will be known ~10am-11am. Beam is expected to be back around 12am.
FixedTEST Wed Mar 6 15:02:51 2019 ValerianMUST2Hardware3-alphaCooling temperature is relevant for the resolution
Using run 52 -> 13deg and run 87 -> -5deg.

We see that the resolution improves at -5 degree. See attached picture as an example for MM2 X.
Attachment 1: MM2X_13deg.png
MM2X_13deg.png
Attachment 2: MM2X_minus5deg.png
MM2X_minus5deg.png
FixedTEST Thu Mar 28 15:39:01 2019 ValerianOFFLINESoftwareN/AStatus of the converion with VAMOS program
The conversion with VAMOS program was validated using run_0020 from com2019


Program output as a ref :

T1 : 9978458
T2 : 9978458
checking multiplicities
Reading: 99.9152 %MULTIPLICITIES OK!
checking values
Reading: 99.9152 %%
DETECTOR NUMBERS ARE OK!!!!!
STRIP NUMBERS ARE OK!!!!!
ENERGY VALUES ARE OK!!!!!
TIME VALUES ARE OK!!!!!