MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 12 of 132  Not logged in MUGAST
Pinned, e786s, Wed Apr 10 13:30:48 2019, Valerian, Adrien and Antoine (edit by Louis), OFFLINE, Software, N/A, How to perform analysis for e786s 
[U][B]
Here is the updated procedure to convert a run, with VAMOS data and add those data to the Kinematic plot.
[/B][/U]
Fixed, , Mon Jun 24 14:14:17 2019, Valerian, Adrien - Dudouet, OFFLINE, General, , p,p' analysis of run49 Screenshot_from_2019-06-24_14-09-39.pngKine46Arpp.pngGamma46Arpp.png
 
Fixed, e744s, Mon Apr 15 12:15:22 2019, Valerian and Sylvain, OFFLINE, Software, CH2, Kinematic line 2p ELabThetaLab_new.pngEcm2p_new.png
 
Fixed, e744s, Thu Apr 11 16:07:59 2019, Valerian and Louis, OFFLINE, Software, CH2, HF resolution T_CATS2_HFns.png
Using the value of the HF=83,4ns. We can obtain the calibrated plot of T_CATS2_HF which is joined and gives us roughly a 2-3 ns resolution for the HF
Fixed, TEST, Wed Apr 3 15:49:02 2019, Valerian and Jenn, Chloé and François , OTHER, Hardware, N/A, Electronic scheme of VAMOS and MUGAST VAMOS_electronic_scheme.pdfVAMOS_electronic_scheme.pptxMUGAST_Electronic_scheme_v2.pptxMUGAST_Electronic_scheme_v3.pdfMUGAST_Electronic_scheme_v3.pptx
Edit : 4/04/19 Valerian and Jenn small correction of MUGAST scheme
Fixed, TEST, Mon Mar 4 12:28:26 2019, Valerian and Iulian, MUST2, General, 3-alpha, No DECS and acq error run 47-48-49. Das Saved after problem fixed run49_error_acq.png
Fixed. Solution:
1) CENTRUM not configured on GENTRUM Master
2) GMT matrix on GMT3 (2nd slave) was all 0
Fixed, e744s, Sun Apr 14 12:11:52 2019, Valerian and Iulian, OFFLINE, Software, CH2, VERY VERY preliminary results Gamma-p EPCM_Brho_gamma.pngPossiblePafterGamma_ToF.pngEpcm_gamma.png
Around 8-10 events are found in the good energy vs Brho region and Si_T vs Si_E region for the gamma emission.

Joined are :
Fixed, e744s, Thu Apr 11 18:20:27 2019, Valerian and Diego, OFFLINE, Software, CH2, Timing issue between vamos and mugast T_MUGAST_FPMW.pngT_MUGAST_FPMW1.png
A cut is seen on the TAC between MUGAST and the focal plane multiwire of VAMOS when one select XF or DC0_Y>-1500

Fixed, e744s, Fri Apr 12 22:44:43 2019, Valerian and Diego, OFFLINE, Software, CH2, 13N measured in Vamos do correspond to protons events in MUST2 Vamos13N_and_MUST2protons.png
Doing a cut on M vs M/Q corresponding to 13N one can see that most of the events do correspond to protons events in MUST2!!!
Fixed, e744s, Wed Apr 17 13:48:25 2019, Valerian and Diego, RUN, Software, CH2, New Dalitz plot with good angles in vamos DalitzGoodAngle.png
The previous Dalitz plot was wrong as I was using the angle from vamos as polar angles.
Now that it is corrected we see that this decay seems sequential.
Fixed, TEST, Wed Mar 27 11:06:33 2019, Valerian and Cyril, GRIT, Hardware, 3-alpha, Evolution of resolution with temperature MG4_13_deg.pngMG4_minus_4_deg.png
For the mugast telescope, changing the temperature from 13deg to minus 4deg doesn't seem to have an impact as strong as for the MUST2 telescopes.
Still, the resolution improve with a lower temperature, but the improvement is of only 0.1 channel... (See joined screenshots)
Fixed, TEST, Thu Mar 21 13:28:06 2019, Valerian and Adrien, DAQ, Software, N/A, First fully functionnal time calibration run on X and Y of MG1 CALIMEROY1.pngFIRST_TIMECALIBRATION_WITHOUT_CALIMERO.png
Our program is able to perform the time calibration of our detector for both X and Y, see picture attached.
Fixed, e786s, Mon Jun 24 16:50:48 2019, Valerian and Adrien, OFFLINE, Software, Cryo-3He, 3He-d kinematics Kine47K.png
To plot those kinematics, there is a macros called kine.cxx

The first plot correspond to the Silicon energy in MUGAST corrected for energy loss (some improvement might be needed)
Fixed, e786s, Wed Jun 26 09:56:17 2019, Valerian and Adrien, RUN, General, Cryo-3He, Identification E-TOF MUGAST ETOF_d.pdfETOF_d_vamos.pdf
Light particle ID in MUGAST (no S1  because shitty time).

The red cut is on what we believe is deuterium.
Fixed, e775s, Wed Mar 4 11:06:49 2020, Valerian Irene, OFFLINE, General, N/A, Second 2+  Second2PlusCurrentStat.pdf
Current comparison between the CD2 target and CD2 + Au target.
Fixed, e744s, Wed Apr 17 07:04:24 2019, Valerian (Mariluz was the one in charge of AGATA), AGATA, Software, CH2, Cristal 4A stopped 
Cristal 4A was stopped during the night, see AGATA logbook for more details.
Fixed, e768s, Wed Jul 31 14:32:53 2019, Valerian & Co, RUN, General, N/A, Beam intensity dropped index.jpgscalers_run160_11.png
unstable beam since 15min... Intensity dropped from 8e6 to 1e5

Edit : Beam is back at 8 10^6 pps
Fixed, e786s, Tue Jun 25 08:23:58 2019, Valerian , BEAM, General, N/A, Beam status 
Currently there is no beam since 22h-> Thunder + no more 48Ca sample. The sample was out during the night.

The "sourcier" on-call arrived at 8h15. By talking to people in shift at the PCP they told me that more will be known ~10am-11am. Beam is expected to be
Fixed, TEST, Wed Mar 6 15:02:51 2019, Valerian, MUST2, Hardware, 3-alpha, Cooling temperature is relevant for the resolution MM2X_13deg.pngMM2X_minus5deg.png
Using run 52 -> 13deg and run 87 -> -5deg.

We see that the resolution improves at -5 degree. See attached picture as an example for MM2 X.
Fixed, TEST, Thu Mar 28 15:39:01 2019, Valerian, OFFLINE, Software, N/A, Status of the converion with VAMOS program 
The conversion with VAMOS program was validated using run_0020 from com2019