Pinned, e786s, Wed Apr 10 13:30:48 2019, Valerian, Adrien and Antoine (edit by Louis), OFFLINE, Software, N/A, How to perform analysis for e786s
|
[U][B]
Here is the updated procedure to convert a run, with VAMOS data and add those data to the Kinematic plot.
[/B][/U]
|
Fixed, , Mon Jun 24 14:14:17 2019, Valerian, Adrien - Dudouet, OFFLINE, General, , p,p' analysis of run49  
|
|
Fixed, e744s, Mon Apr 15 12:15:22 2019, Valerian and Sylvain, OFFLINE, Software, CH2, Kinematic line 2p 
|
|
Fixed, e744s, Thu Apr 11 16:07:59 2019, Valerian and Louis, OFFLINE, Software, CH2, HF resolution
|
Using the value of the HF=83,4ns. We can obtain the calibrated plot of T_CATS2_HF which is joined and gives us roughly a 2-3 ns resolution for the HF |
Fixed, TEST, Wed Apr 3 15:49:02 2019, Valerian and Jenn, Chloé and François , OTHER, Hardware, N/A, Electronic scheme of VAMOS and MUGAST    
|
Edit : 4/04/19 Valerian and Jenn small correction of MUGAST scheme |
Fixed, TEST, Mon Mar 4 12:28:26 2019, Valerian and Iulian, MUST2, General, 3-alpha, No DECS and acq error run 47-48-49. Das Saved after problem fixed
|
Fixed. Solution:
1) CENTRUM not configured on GENTRUM Master
2) GMT matrix on GMT3 (2nd slave) was all 0
|
Fixed, e744s, Sun Apr 14 12:11:52 2019, Valerian and Iulian, OFFLINE, Software, CH2, VERY VERY preliminary results Gamma-p  
|
Around 8-10 events are found in the good energy vs Brho region and Si_T vs Si_E region for the gamma emission.
Joined are :
|
Fixed, e744s, Thu Apr 11 18:20:27 2019, Valerian and Diego, OFFLINE, Software, CH2, Timing issue between vamos and mugast 
|
A cut is seen on the TAC between MUGAST and the focal plane multiwire of VAMOS when one select XF or DC0_Y>-1500
|
Fixed, e744s, Fri Apr 12 22:44:43 2019, Valerian and Diego, OFFLINE, Software, CH2, 13N measured in Vamos do correspond to protons events in MUST2
|
Doing a cut on M vs M/Q corresponding to 13N one can see that most of the events do correspond to protons events in MUST2!!! |
Fixed, e744s, Wed Apr 17 13:48:25 2019, Valerian and Diego, RUN, Software, CH2, New Dalitz plot with good angles in vamos
|
The previous Dalitz plot was wrong as I was using the angle from vamos as polar angles.
Now that it is corrected we see that this decay seems sequential. |
Fixed, TEST, Wed Mar 27 11:06:33 2019, Valerian and Cyril, GRIT, Hardware, 3-alpha, Evolution of resolution with temperature 
|
For the mugast telescope, changing the temperature from 13deg to minus 4deg doesn't seem to have an impact as strong as for the MUST2 telescopes.
Still, the resolution improve with a lower temperature, but the improvement is of only 0.1 channel... (See joined screenshots) |
Fixed, TEST, Thu Mar 21 13:28:06 2019, Valerian and Adrien, DAQ, Software, N/A, First fully functionnal time calibration run on X and Y of MG1 
|
Our program is able to perform the time calibration of our detector for both X and Y, see picture attached. |
Fixed, e786s, Mon Jun 24 16:50:48 2019, Valerian and Adrien, OFFLINE, Software, Cryo-3He, 3He-d kinematics
|
To plot those kinematics, there is a macros called kine.cxx
The first plot correspond to the Silicon energy in MUGAST corrected for energy loss (some improvement might be needed)
|
Fixed, e786s, Wed Jun 26 09:56:17 2019, Valerian and Adrien, RUN, General, Cryo-3He, Identification E-TOF MUGAST 
|
Light particle ID in MUGAST (no S1 because shitty time).
The red cut is on what we believe is deuterium.
|
Fixed, e775s, Wed Mar 4 11:06:49 2020, Valerian Irene, OFFLINE, General, N/A, Second 2+
|
Current comparison between the CD2 target and CD2 + Au target. |
Fixed, e744s, Wed Apr 17 07:04:24 2019, Valerian (Mariluz was the one in charge of AGATA), AGATA, Software, CH2, Cristal 4A stopped
|
Cristal 4A was stopped during the night, see AGATA logbook for more details. |
Fixed, e768s, Wed Jul 31 14:32:53 2019, Valerian & Co, RUN, General, N/A, Beam intensity dropped 
|
unstable beam since 15min... Intensity dropped from 8e6 to 1e5
Edit : Beam is back at 8 10^6 pps |
Fixed, e786s, Tue Jun 25 08:23:58 2019, Valerian , BEAM, General, N/A, Beam status
|
Currently there is no beam since 22h-> Thunder + no more 48Ca sample. The sample was out during the night.
The "sourcier" on-call arrived at 8h15. By talking to people in shift at the PCP they told me that more will be known ~10am-11am. Beam is expected to be |
Fixed, TEST, Wed Mar 6 15:02:51 2019, Valerian, MUST2, Hardware, 3-alpha, Cooling temperature is relevant for the resolution 
|
Using run 52 -> 13deg and run 87 -> -5deg.
We see that the resolution improves at -5 degree. See attached picture as an example for MM2 X. |
Fixed, TEST, Thu Mar 28 15:39:01 2019, Valerian, OFFLINE, Software, N/A, Status of the converion with VAMOS program
|
The conversion with VAMOS program was validated using run_0020 from com2019
|
|