Fixed, e793s, Wed Mar 10 15:15:44 2021, Charlie, OTHER, General, , 48Ti Kinematics (additional)  
|
Supplementary to Adrien's kinematic calculations of 47Ti(d,p)48Ti, we have found a paper suggesting that by far the most strongly populated state in 48Ti
is at 5.65 MeV. There is also a doublet of strong states at around 4.4 MeV, and two more strongly populated states at 6.06 and 6.33 MeV.
|
Fixed, e793s, Sat Mar 13 14:49:40 2021, Charlie, OFFLINE, General, CD2, TWOFNR for 4 MeV, 0f5/2  
|
In response to Franco's comment [URL=https://caeelog.in2p3.fr/MUGAST/6119]here[/URL], I ran some quick TWOFNR simulations for a 0f5/2 transfer on to 4 MeV,
on to spin 2 or 3. The attached files are named as follows:
|
Fixed, e793s, Tue Mar 16 23:57:29 2021, Charlie, RUN, General, CD2, run63 scaler graph at 00h00
|
The scaler graph had frozen at 15:45, so all of the screenshots of it since then show the same section. Refreshed graph of the last few hours attached. |
Fixed, e744s, Sat Apr 13 22:45:27 2019, Beyhan, Sylvain, Jaromir, AGATA, Software, N/A, Agata yellow phase 1 minute
|
Agata yellow 1 minute
All the trigers emitted by (every) single crystal were refused by ACQ for 1 minute.
|
Fixed, e744s, Sat Apr 13 19:27:16 2019, Beyhan, Jaromir, OTHER, General, N/A, Spreadsheet with a list of runs up to 122    
|
Resides also in home directory
runs_list.ods
|
Fixed, e744s, Sun Apr 14 12:32:32 2019, Beyhan, François, OTHER, General, , Alarm in G2 but no beam stop
|
Same issue as Saturday evening.
Alarm in G2 at 12:30 due to Exogam filling with liquid nitrogen.
Beam was not stopped.Acquisition of data ongoing |
Fixed, e744s, Mon Apr 15 17:17:57 2019, Beyhan +..., OTHER, General, , Spreadsheet with a list of runs up to 130
|
|
Fixed, e744s, Wed Apr 10 06:51:35 2019, Beyhan, BEAM, General, , 14N7+ beam characteristics and settings at VAMOS   
|
|
Fixed, e744s, Thu Apr 11 18:36:34 2019, Beyhan, BEAM, General, , before optimization : beam reconstructed profil with VAMOS and assoicated settings 
|
target : hole
cats2 out
about 4000 pps triggering VAMOS |
Fixed, e744s, Sat Apr 13 20:37:16 2019, Beyhan, OTHER, General, , Alarm in G2
|
Alarm signal from G2.
No beam since 20:30
PCP will have a look in G2, following the procedures.
|
Documents, e744s, Tue Apr 16 12:15:28 2019, Beyhan, OTHER, General, , VAMOS settings for C run
|
|
Fixed, e786s, Fri Jun 28 09:56:59 2019, Bertrand, Valerian and Adrien, BEAM, General, N/A, Dipole stopped in the morning?
|
Dipole restart at 10. Shoudl be checked with time stamp. |
Fixed, e768s, Mon Jul 15 12:57:53 2019, Aranaud, Nicolas, Marlène, François, TARGET, General, LiF, Targets position 6x
|
Targets have been mounted on target ladder and are now in reaction chamber |
Fixed, e744s, Fri Apr 12 17:12:42 2019, Antoine, OFFLINE, General, CH2, 13N identified in VAMOS  
|
Identification plots.
|
Fixed, e744s, Mon Apr 15 10:07:23 2019, Antoine, VAMOS, Hardware, , Brho VAMOS
|
During the change, Johan entered in G1 and connected a mass cable for the drift chambers. |
Fixed, e768s, Fri Jul 26 19:47:18 2019, Andres & Franco, RUN, General, LiF, Check beam intensity and profile run152 h 19.30
|
|
Fixed, e768s, Fri Jul 26 23:58:08 2019, Andres & Franco, RUN, General, LiF, Check beam intensity and profile run152 h 23.40
|
|
Fixed, com2019, Tue Apr 9 17:23:27 2019, Adrien, Valerian, Louis et Thomas, OFFLINE, General, CD2, Beam was not centered in run 256 
|
[SIZE=3]Here is the impact matrix in MUST2 for impact matrix for run 256. Beam is not centered.[/SIZE]
Edit: second plot for run 244 with 1mg/cm2 target, CATS trigger. Can see that beam is uncentered but in different way than in run 256. |
Fixed, e744s, Thu Apr 11 15:16:10 2019, Adrien, Valerian, Louis, CATS, General, CH2, run77 CATS efficiency
|
CATS efficiency has been computed for run 77 using T_FagHF an T_Si_Cats1 with different triggers:
Trigger GATCONF_MASTER<8 (MUST+Mugast) : 94%
|
Fixed, e793s, Wed Mar 10 22:19:22 2021, Adrien, Freddy, Wilton and Nigel, OFFLINE, General, CD2, Offline analysis of run 51 and 52 using ganil files
|
We noted that the gamma ray efficiency calculated from file converted from AGATA was close 100%. We concluded that the conversion program was reauiring
a gamma ray to be present.
|
|