Fri Mar 12 19:15:19 2021 |
Charlie, Nigel (watched by Wilton) | RUN | General | CD2 | Beam alignment tuning |
During part of run #61, Nigel tuned the beam alignment (using the MUST2 hit pattern as the diagnostic). The beam had shifted after the restarting of the ISOL TIS. The beam came back at around 18:30 and tuning finished at 19:15.
** Disregard the data from this run between ~17:15 (beam lost) and 19:15 (tuning finished).
The run should be OK after 19:15.
** Don't tell Bertrand that Nigel used the d*p*le ... |
Fixed | e793s |
Fri Mar 12 20:43:38 2021 |
Cyril, Louis | OFFLINE | General | CD2 | DWBA |
DBWA analysis have been performed with TWOFNR, here the comparison with data for the 0, 2 and 4 MeV peaks.
1p1/2 (black line) and 0f7/2 (red line) |
Attachment 1: DWBA.png
|
|
Attachment 2: DWBA2.png
|
|
Fixed | e793s |
Fri Mar 12 20:54:30 2021 |
mugast | RUN | General | CD2 | summary of run 61 |
|
Attachment 1: scalers.png
|
|
Attachment 2: vamos.png
|
|
Attachment 3: Screenshot_from_2021-03-12_20-57-53.png
|
|
Attachment 4: Screenshot_from_2021-03-12_20-58-15.png
|
|
Attachment 5: Screenshot_from_2021-03-12_20-58-45.png
|
|
Fixed | e793s |
Fri Mar 12 22:03:31 2021 |
Nishu, GiB | VAMOS | Hardware | CD2 | VAMOS tripped @ ~ 21:00 |
Back to normal around 22:00 after restarting HV 5 to 11 (except 10 which was still on) |
Attachment 1: Screenshot_from_2021-03-12_22-07-22.png
|
|
Fixed | e793s |
Fri Mar 12 22:26:55 2021 |
julien, nishu | VAMOS | Hardware | CD2 | VAMOS tripped @ ~ 22:24 |
back again to normal, |
Fixed | e793s |
Fri Mar 12 22:31:46 2021 |
julien, nishu | VAMOS | Hardware | CD2 | VAMOS tripped @ ~ 22:24 ans again ~ 22:45 |
back again to normal after restarting the HV
(22:39) |
Attachment 1: vamos_nc.png
|
|
Attachment 2: Screenshot_from_2021-03-12_22-33-47.png
|
|
Attachment 3: Screenshot_from_2021-03-12_22-47-38.png
|
|
Fixed | e793s |
Fri Mar 12 23:16:16 2021 |
julien, nishu | RUN | Hardware | CD2 | vamos count rate goes down to 0 once again |
We reduced the high voltage limit to 520v from 525v.
please see the screen shots of the focal planes attached below:. |
Attachment 1: IMG20210312231358.jpg
|
|
Attachment 2: IMG20210312230429.jpg
|
|
Fixed | e793s |
Fri Mar 12 23:27:58 2021 |
julien, nishu | RUN | General | CD2 | summary of run 61 |
below attached the screenshots of scalers and spectra |
Attachment 1: Screenshot_from_2021-03-12_23-31-23.png
|
|
Attachment 2: Screenshot_from_2021-03-12_23-31-07.png
|
|
Attachment 3: Screenshot_from_2021-03-12_23-30-43.png
|
|
Attachment 4: Screenshot_from_2021-03-12_23-30-22.png
|
|
Attachment 5: Screenshot_from_2021-03-12_23-29-52.png
|
|
Fixed | e793s |
Fri Mar 12 23:54:52 2021 |
julien, nishu, Faïrouz | VAMOS | Hardware | CD2 | Vamos tripped @ 23h35 & fixed |
|
Fixed | e793s |
Sat Mar 13 01:41:21 2021 |
Juan Lois & faïrouz | RUN | General | CD2 | run61 screenshots at 1h40 |
|
Attachment 1: run61_TAC_01h35.png
|
|
Attachment 2: run61_MG_ToF_01h35.png
|
|
Attachment 3: run61_MM_DeE_01h35.png
|
|
Attachment 4: run61_MM_ToF_01h35.png
|
|
Attachment 5: run61_MG_IMPACT_MATRIX_01h35.png
|
|
Attachment 6: run61_Vamos-MW_01h35.png
|
|
Attachment 7: run61_MM_IMPACT_MATRIX_01h35.png
|
|
Attachment 8: run61_Scalers_01h34.png
|
|
Fixed | e793s |
Sat Mar 13 02:31:33 2021 |
Faïrouz, Juan Lois | VAMOS | Hardware | CD2 | Vamos tripped @ 2h32 & fixed |
|
Fixed | e793s |
Sat Mar 13 03:50:54 2021 |
Faïrouz, Juan Lois | RUN | General | CD2 | run61 screenshots at 3h44 |
|
Attachment 1: Run61_scalers_03h44.png
|
|
Attachment 2: Run61_MG_IMPACT_03h44.png
|
|
Attachment 3: Run61_MM_ToF_03h44.png
|
|
Attachment 4: Run61_MM_DeE_03h44.png
|
|
Attachment 5: Run61_NG_TOF_03h44.png
|
|
Attachment 6: Run61_TAC_03h44.png
|
|
Attachment 7: Run61_VAMOS_MW_03h44.png
|
|
Attachment 8: Run61_MM_IMPACT_03h44.png
|
|
Pending | e793s |
Sat Mar 13 05:11:08 2021 |
Faïrouz, Juan Lois | AGATA | Software | CD2 | Problem with AGATA acquisition started at 4h40 |
There is a problem with AGATA Acquisition. All the bars in the global status & control are yellow!!!
This problem started at 4h40.
We called the acquisition astreinte but he doesn't know how to fix the problem.
We called Emmanuel but we got on the answering machine. We will call him again at 7 am.
The count rate of AGATA in the scaler looks ok: ~ 1200 |
Attachment 1: run61-scalers_5h19.png
|
|
Fixed | e793s |
Sat Mar 13 05:33:41 2021 |
Faïrouz, Juan Lois | RUN | General | CD2 | run61 screenshots at 5h30 |
|
Attachment 1: run61_scalers_05h30.png
|
|
Attachment 2: run61_MM_IMPACT_05h30.png
|
|
Attachment 3: run61_VAMOS_MW_05h30.png
|
|
Attachment 4: run61_TAC_05h30.png
|
|
Attachment 5: run61_MG_ToF_05h30.png
|
|
Attachment 6: run61_MM_DeE_05h30.png
|
|
Attachment 7: run61_MM_ToF_05h30.png
|
|
Attachment 8: run61_MG_IMPACT_5h30.png
|
|
Fixed | e793s |
Sat Mar 13 07:18:10 2021 |
OttoRun | RUN | General | CD2 | Run62 |
*************************
Run : 62
*************************
Start at 2021-03-13 07:17:49.732042
run62. ACQ DT
starting again after centering the beam on the target
Beam: 3.5e5 pps
target: CD2 0.5mg
Trigger are MUGAST/MM/CATS%
Stop at 2021-03-15 10:05:15.581255
Stop comment: stop run
Stop at 2021-03-17 07:17:25.231024
Stop comment: Vamos stopped writing data at 06:50 |
Fixed | e793s |
Sat Mar 13 07:26:40 2021 |
Faïrouz, Juan Lois | RUN | General | CD2 | End of run61 screenshots at 7h20 |
RUN 61 stopped to let Emmanuel fix the AGATA acquisition problem. |
Attachment 1: run61_MG_IMPACT_7h20.png
|
|
Attachment 2: run61_MM_ToF_7h20.png
|
|
Attachment 3: run61_MM_DeE_7h20.png
|
|
Attachment 4: run61_MG_ToF_7h20.png
|
|
Attachment 5: run61_TAC_7h20.png
|
|
Attachment 6: run61_Vamos-MW_7h20.png
|
|
Attachment 7: run62_MM_IMPACT_7h20.png
|
|
Fixed | e793s |
Sat Mar 13 07:29:56 2021 |
Faïrouz, Juan Lois | AGATA | Software | CD2 | AGATA acquisition problem fixed by Emmanuel |
|
Fixed | e793s |
Sat Mar 13 07:31:13 2021 |
Faïrouz, Juan Lois | RUN | General | CD2 | Run 62 scalers |
|
Attachment 1: run62_scaler_7h20.png
|
|
Fixed | e793s |
Sat Mar 13 09:19:14 2021 |
Lynda, Laetitia, Chloe | ONLINE | General | CD2 | run62 screenshots at 9h10 |
Online spectra reset at 9h20 |
Attachment 1: run62_MG_IMPACT_9h10.png
|
|
Attachment 2: run62_MM_ToF_9h10.png
|
|
Attachment 3: run62_MM_DeE_9h10.png
|
|
Attachment 4: run62_MG_ToF_9h10.png
|
|
Attachment 5: run62_TAC_9h10.png
|
|
Attachment 6: run62_FSC_9h10.png
|
|
Attachment 7: run62_Vamos-MW_9h10.png
|
|
Attachment 8: run62_MM_IMPACT_9h10.png
|
|
Attachment 9: run62_Theta_E_9h10.png
|
|
Attachment 10: run62_scaler_9h15.png
|
|
Fixed | e793s |
Sat Mar 13 10:11:44 2021 |
Adrien | OFFLINE | General | CD2 | Offline analysis of run 51-61 |
Run 51 to 61 are converted and analysed.
I fixed the gamma/no gamma normalisation after binning change.
We clearly see :
a state at 2.5 MeV that decay directly to the g.s. and a state at around 5 MeV with a 3 gamma cascade.
To do list:
- Add an angle dist in AngDist.C macro for the states around 2MeV (you can remove the Ex plot)
- Put Logy in all the canvas for the angle dist;)
- create a new macro showing the EDC 1D histo gated on several sliding windows in Ex to see the the gamma peak changing height
- add arrow or line indication the gamma rays position on every plots
- build the level scheme based on this (there is a preliminary scheme posted earlier by Manu based on gamma-gamma). |
Attachment 1: Plot51-61.png
|
|
Attachment 2: Angle51-61.png
|
|