MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 124 of 132  Not logged in MUGAST
Status ExpNbr Date Author Type Category Target-Source Subjectdown Text Attachments
Fixedcom2019 Wed Apr 3 16:24:37 2019 AdrienCATSSoftwareN/ACalib file from T.RogerHere are the calibration file provided by
T. Roger.
 CATS2_Y.vamos2019CATS2_X.vamos2019CATS1_Y.vamos2019CATS1_X.vamos2019 
PinnedTEST Tue Feb 26 09:30:21 2019 FreddyOTHERHardwareN/ACabling - MUVI / HT-BT / SA-SLCabling scheme - to update until final  Cabling_2019_03_01.pdf 
Fixede744s Thu Apr 11 00:57:34 2019 iulianOTHERHardwareCH2CH2 target thicknesstarget CH2 104 um (2nd position)

Brho 14N6+ CATS2 
  
Fixede768s Mon Jul 22 05:30:37 2019 Faïrouz & SylvainRUNGeneralLiFCF put because AGATA went crazyCF put because AGATA went crazy. 
The beam profile is shifted in comparison
to the initial profile at midnight. The beam
  
Fixede744s Tue Apr 16 08:23:38 2019 Marion, DieterCATSHardwareCH2CATS tripping - lowering bias8:24 Faraday in.
-5V on CATS.
550V.
  
Fixede786s Fri Jun 28 08:57:21 2019 FreddyCATSGeneralCryo-3HeCATS scaler not compatible with beam rateThe CATS scaler si now around 100-120 kHz
while the beam rate is still 40 kHz.
 ScalerCATSproblem.png 
Fixede744s Fri Apr 12 08:19:31 2019 MarlèneOFFLINEGeneral CATS profiles RUN87   CATS_pos_RUN87.pngCATS_chargeX_run87.pngCATS_chargeX_2_run87.pngCATS_chargeY_run87.pngCATS_ChargeY_2_run87.png 
Fixedcom2019 Fri Apr 5 14:54:09 2019 mugastCATSHardwareN/ACATS high voltage lowered by 20VCATS high voltage lowered by 20V from 580V
to 560V (on request of J. Pancin)
  
Fixede744s Thu Apr 11 19:47:15 2019 MarlèneOFFLINEGeneral CATS charges in RUN76 and RUN77Offline analysis to reconstruct the charges
in X and Y for CATS.
The charges are lower in RUN77 because bias
 CATS_stripY_run76.pdfCATS_stripX_run76.pdfCATS_stripY_run77.pdfCATS_stripX_run77.pdfCATS_RUN77.pdf 
Fixede793s Thu Mar 11 04:34:58 2021 ablaihan, louisCATSHardwareCD2CATS and VAMOS trippedat 4h15 CATS and VAMOS tripped probably due
to too high beam intensity (~1.2x10^6 pps).
We switched them on again at 4h30. All the
 Scaler_run53_4h30.png 
Fixede744s Thu Apr 11 09:05:37 2019 mugastCATSGeneralN/ACATS HV changed to 580CATS HV changed from 600V to 580V.   
Fixede744s Tue Apr 16 11:40:04 2019 mugastCATSHardwareN/ACATS HVCATS2 HV was decreased to 540 V at 11h30 to
avoid the overcurrent.
  
Fixede786s Mon Jun 24 03:08:49 2019 MarlèneRUNGeneralCryo-3HeBrho issueWe observe a change in the Brho of VAMOS :
the charged states are divided in 2 !!!
 Brho_vamos.png 
Fixede768s Fri Jul 19 00:03:25 2019 JennBEAMGeneral Brho information 15 Oxygen beam 4.7MeV/u    
Fixede768s Fri Jul 19 00:06:35 2019 JennBEAMGeneral Brho information 15 Oxygen beam 4.7MeV/u   New_Doc_2019-07-18_23.58.18_1.pdf 
Fixede744s Fri Apr 12 01:56:35 2019 Jenn, Louis, Cyril,Daniele and ChloeBEAMGeneralEmptyBrho for the new 14O setting RUN86CATS2 on and target position 1: hole
Beam intensity in CATS: 4E4
VAMOS intensity 1.3E4
 Brho_14O_run86.png20190412_193918.jpg 
Fixed  Fri Apr 5 19:05:56 2019 Marlène NicolasGRITGeneral Brho beam & 17OBrho of  16O @ 6 MeV/A after 1mg/cm2 = 0.68906
Brho of 17O for g.s. after 1 mg/cm2=0.71065
Brho of 17O @ 871 keV after 1mg/cm2=0.70831
  
Fixede744s Fri Apr 12 06:51:59 2019 LouisBEAMGeneralN/ABrho and energy of the 14O beam   DSC_3261.JPG 
Fixede744s Mon Apr 15 10:07:23 2019 AntoineVAMOSHardware Brho VAMOS
During the change, Johan entered in G1 and
connected a mass cable for the drift chambers.
 20190415_094107.jpg 
Fixede768s Tue Jul 16 15:13:01 2019 Jenn, DIegoVAMOSGeneral Brho    E768_BRHO.pdf 

ELOG Home Page