Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Text |
 |
Fixed | TEST |
Fri Feb 5 12:44:42 2021 |
Franco | GRIT | Hardware | N/A | Pulser on MG11 MUFEE Y | I managed to obtain the spectrum with the
pulser on the annular (Y side, namely sectors).
The raw strip numbers where I should have |
  |
Ongoing | e793s |
Wed Mar 3 17:12:57 2021 |
Franco | S1 | Hardware | N/A | Schema of the new S1 | The signals of the new S1 will be splitted
among 6 Mugast boards, according to the scheme
attached.
|
|
Fixed | e793s |
Wed Mar 3 17:18:42 2021 |
Franco | GRIT | General | N/A | MUVI's scheme and connections on the chamber | |
 |
Fixed | e793s |
Mon Mar 8 19:01:26 2021 |
Franco | GRIT | General | 3-alpha | Energy and time calibrations before experiment | Energy resolutions:
MG1: 45 keV
|
8x |
Fixed | e793s |
Tue Mar 9 11:47:14 2021 |
Franco | RUN | General | N/A | TACS calibration | Coefficients uploaded in MUGAST/e793s/calibTACS_e793s.cal
(set offsets to 0 and kept only the slope) |
 |
Fixed | e793s |
Thu Mar 11 21:29:43 2021 |
Franco | RUN | General | CD2 | Alignment in time of the VAMOS sections | The aligned time is saved in a variable called
MWT in the output tree |
|
Fixed | e793s |
Fri Mar 12 09:55:30 2021 |
Franco | GRIT | General | CD2 | MM5 | The first plot attached has been done by artificially
removing 7 deg in theta lab, just to see
if the the kinematic lines of 47K(d,d) and |
 |
Fixed | e793s |
Sat Mar 13 13:16:04 2021 |
Franco | OFFLINE | General | CD2 | Angular distributions | - Updated the macro for the angular distributions.
- For the angular distribution of the peak
at 4 MeV excitation energy I think we need |
 |
Fixed | e793s |
Sun Mar 14 14:52:14 2021 |
Franco | OFFLINE | General | CD2 | Gating above Sn | |
|
Fixed | e793s |
Sun Mar 14 14:57:35 2021 |
Franco | GRIT | General | CD2 | LV & HV of Mugast-MUST2 | For future reference... |
|
Fixed | e793s |
Wed Mar 17 19:19:05 2021 |
Franco | OFFLINE | General | CD2 | Mugast detectors disaligned in Ex | The Ex distributions gated on the different
MG detectors show large differences, up to
500 keV. In the attached figure I show as |
 |
Fixed | e775s |
Fri Feb 28 22:58:31 2020 |
Franck, Sylvain | ONLINE | General | CD2 | MUGAST Spectra Run 153 | Run 153 (target #2 CD2+Au)
MUGAST Spectra reset at start of run (~ 20h) |
   |
Fixed | e768s |
Mon Jul 22 09:40:06 2019 |
Franck, François, Adrien, Jérémy, Nicolas | ONLINE | General | LiF | Screenshots run 124 | |
22x |
Fixed | e768s |
Mon Jul 22 10:01:12 2019 |
Franck, François D | BEAM | General | LiF | Beam profile | Slight shift in vertical +1 mm (with respect
to this morning at 8:30)?
|
|
Fixed | e768s |
Fri Jul 19 21:43:35 2019 |
Franck & Faïrouz | RUN | General | LiF | screenshots run 116 @ 21h30 | |
17x |
Fixed | e768s |
Sat Jul 20 00:01:27 2019 |
Franck & Faïrouz | RUN | General | LiF | screenshots run 116 @ 00h00 | Algeria won Africa nations cup!!! :-)) |
19x |
Fixed | e768s |
Mon Jul 22 13:40:41 2019 |
Franck | ONLINE | General | LiF | Run 125 screenshots | |
22x |
Fixed | e768s |
Mon Jul 29 13:46:11 2019 |
Faïtrouz, Nicolas & Freddy | RUN | General | LiF | Beam intensity increased to 7e6 pps | |
 |
Fixed | e768s |
Mon Jul 22 08:29:19 2019 |
Faïrouz, Sylvain, Francois et Franck, Bertrand | BEAM | General | LiF | Beam profile updated | To solve the very high counting rate observed
on AGATA (and on MUST2 with a lesser degree),
the beam was retuned.
|
 |
Fixed | e744s |
Tue Apr 16 20:58:40 2019 |
Faïrouz, Julian, Jaromir & Sylvain | RUN | General | CH2 | Run 136 started |
Comment: automatic logger didnt work
|
|