MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 121 of 132  Not logged in MUGAST
Fixed, e793s, Fri Feb 12 08:52:30 2021, mugast, RUN, General, 3-alpha, run 613: long alpha run  
all Muvi in trigger, mugast stand alone. all detector Bias on.
Fixed, e793s, Fri Mar 5 16:14:21 2021, OttoRun, RUN, General, 3-alpha, Run618 MGRAWEY.pngMGRAWEX.pngMMRAWEY.pngMMRAWEX.png
*************************
Run : 618
*************************

Start at 2021-03-05 16:13:37.198228

run 3 alpha with pedestal and mugast DAQ
Fixed, e793s, Fri Mar 5 16:31:08 2021, OttoRun, RUN, General, 3-alpha, Run619 
*************************
Run :619
*************************

Start at 2021-03-05 16:30:39.722907

run 3 alpha without pedestals for MG but with pedestals for MM
Fixed, e793s, Fri Mar 5 16:39:08 2021, OttoRun, RUN, General, 3-alpha, Run620 
*************************
Run : 620
*************************

Start at 2021-03-05 16:38:16.476202

run 3 alpha without pedestal for all detectors, to be used for experiment

Stop at 2021-03-05 16:56:13.657279
Stop comment: type your message here

Stop at 2021-03-05 16:56:14.690583
Stop comment: type your message here

Stop at 2021-03-05 16:56:15.050212
Stop comment: type your message here

Stop at 2021-03-05 16:56:16.082040
Stop comment:

Stop at 2021-03-05 17:13:59.790265
Stop comment:

Stop at 2021-03-05 17:15:58.879697
Stop comment:

Stop at 2021-03-06 13:25:23.248954
Stop comment:

Stop at 2021-03-06 13:25:23.504734
Stop comment:

Stop at 2021-03-06 13:25:23.873972
Stop comment:
Fixed, e793s, Sat Mar 6 13:25:38 2021, OttoRun, RUN, General, 3-alpha, Run630 
*************************
Run : 630
*************************

Start at 2021-03-06 13:15:07.038908

run 3 alpha. time calibrator is on but is not giving any trigger so just sending random stop

Stop at 2021-03-08 09:50:00.232468
Stop comment:

Stop at 2021-03-08 15:28:10.213189
Stop comment:

Stop at 2021-03-08 15:28:10.881754
Stop comment:

Stop at 2021-03-08 15:28:11.447832
Stop comment:
Fixed, e793s, Mon Mar 8 19:01:26 2021, Franco, GRIT, General, 3-alpha, Energy and time calibrations before experiment 8x
Energy resolutions:

MG1: 45 keV
MG2: 45 keV
MG3: 45 keV
MG4: 50 keV
MG5: 50 keV
MG7: 50 keV
Total Mugast: 50 keV

MM1: 50 keV
MM2: 50 keV
MM3: 45 keV
MM4: 50 keV
Total MUST2: 50 keV

MM5 (90 deg): 65 keV
Fixed, e793s, Tue Mar 9 09:43:51 2021, OttoRun, RUN, General, 3-alpha, Run200 
*************************
Run : 200
*************************

Start at 2021-03-08 17:43:53.831102

run 3 alpha

Stop at 2021-03-09 09:43:55.629095
Stop comment: type your message here

Stop at 2021-03-09 09:43:56.774034
Stop comment: type your message here

Stop at 2021-03-09 09:43:57.137511
Stop comment: type your message here

Stop at 2021-03-09 09:43:57.480913
Stop comment: type your message here
Fixed, e793s, Wed Mar 10 13:03:00 2021, OttoRun, RUN, General, 3-alpha, Run41 
*************************
Run : 41
*************************

Start at 2021-03-10 12:58:41.805693

run 3 alpha

Stop at 2021-03-10 13:06:49.699879
Stop comment:
Fixed, e793s, Wed Mar 10 13:09:12 2021, OttoRun, RUN, General, 3-alpha, Run42 
*************************
Run : 42
*************************

Start at 2021-03-10 13:09:04.739262

run 3 alpha

Stop at 2021-03-10 13:30:31.317348
Stop comment: changing trigger
Fixed, e793s, Fri Mar 19 09:54:58 2021, Adrien, Freddy and Franco, GRIT, General, 3-alpha, Alpha calibration and noise on MG3 and MG4 after the experiment 
While starting the alpha source runs after the experiment we found unexpected noise on MG3 and MG4 which cannot be excluded just by masking some Y mates (The X mates were already masked for both of them). We cannot figure out the origin of this noise.

Run 652 and 653 -> alpha runs without pedestal suppression
Run 655 -> alpha run during the night with pedestal suppression. Here MG3 and MG4 are not in the trigger.
Run 658 -> alpha run after an attempt to mask some noisy strips. The number of ORD is anyway high (some 10^4) but we see some alphas on MG3 and MG4.
Run 660 -> same as 658 but with higher thresholds on X (8250) and Y (7600 on MG3 and 7950 on MG4) to write less on disk but actually nothing changes. Therefore we are writing about 2.7 GB per hour.

The other runs (654, 656, 657 and 659) can be discarded.
Fixed, e744s, Wed Apr 17 16:53:53 2019, Sylvain (AGATA), AGATA, General, 152Eu, Run 137 : Eu calibration 
Run stared 2019/04/17

EU efficiency Calibration
Fixed, e786s, Tue Jun 25 10:51:59 2019, OttoRun, RUN, General, 152Eu, Run57 
*************************
Run : 57
*************************

Start at 2019-06-25 10:50:03.672363

152Eu source @ AGATA

Stop at 2019-06-25 14:36:40.442175
Stop comment: end ; source removed
Fixed, , Wed Jan 23 12:24:10 2019, Marlène, GRIT, General, , Change cable MG1T - Exchange of detectors named MG9C & MG10C 
23/01/19

Change of the HT/BT cable of MG1T (the one that had a short cut before when the chamber was closed)

MG9C is now the square detector nb 4 (Micron number) and coupled with the thick detector --> this detector was working properly
MG10C is detector nb 3 (Micron number) --> this detector was noisy before
Fixed, , Fri Jan 25 17:02:25 2019, Marlène, GRIT, General, , Detectors numbering MUGAST_detectors.pdf
Fixed, TEST, Mon Mar 4 16:24:51 2019, valerian marlène, GRIT, General, , RUN52 3 alpha source 4MUST2 no pedestal HV_MUST2_during_run52.pngHV_MUST2_afternightrun52.png3alpha_source_4MUST2_nightrun52.png
RUN52
3 alpha source run with only 4MUST2 (in MUVI3) with pedestal suppression at 13 deg.
Fixed, , Mon Mar 4 17:22:29 2019, Marlene, GRIT, General, , Temperature on MUFEE MUST2 13deg 8x
Temperature given by DAS on MUVI3 (MUST2)
screenshots before run
after run : same values
Fixed, TEST, Thu Mar 7 09:29:47 2019, Marlene, GRIT, General, , run 96 double alpha source run shifted 60mm  run96_MG7_MG11notworking.pngrun96_3alphasource_shifted_MG1-5.pngrun96_HV2.pngrun96_HV1.png
RUN 96

double alpha source
MG1
MG3
MG4
MG5

MG7
-
-
MG11

MM1
MM2
MM3
MM4

Missing strips in Y the same as in run 40

Problem with the annular MG11 -> no current when bias is put... --> to be checked

Problem with the insertion of the target holder --> solved

I also checked again MG9 (still noisy)
and MG10 with 140V I=0,52uA and counting rate is the same order of magnitude as trapezoid. Spectra are OK (not saved).
Fixed, , Tue Mar 12 10:21:17 2019, Marlène, MUST2, General, , Debug Calimero Y test_GECO_masquage_mate2&10activees_seulement.png
Debug of Calimero

test of channels (mate) masking : OK with DAS, OK with GECCO (see attachment) when done in the "disable channels" of GECCO

With calimero, when we are on Y, when we click right to mask a mate we see 'disable mate 2' instead of 'disable mate 10' !!!
Fixed, , Tue Mar 19 19:35:53 2019, marlene, GRIT, General, , RUN 98 3alpha source all detectors 
RUN 98
3 alpha source
all detectors (trap,square, MUST2,annular)
Temp=15deg
Acquisition mugast
Fixed, , Thu Apr 4 17:55:47 2019, Marlène, GRIT, General, , Scalers 
The scalers are

Scaler 1:
1-FAG
2-OR MUGAST
3-OR AGATA
4-OR VAMOS
5-
6-
7-100Hz pulser
8-DT n pulser 100Hz
9-OR BACK
10-OR MUST2
11-OR SQUARE
12-AGATA DIV

Scaler 2:
17-CATS1
18-CATS1 n FAG
19-CATS2