Fixede744s Tue Apr 16 14:13:17 2019 FreddyRUNGeneralCH2Log and scalers RUN 134 @ 14h13
Attachment 1: run134_Mugast_1_8.png
run134_Mugast_1_8.png
Attachment 2: run134_Mugast_1_7.png
run134_Mugast_1_7.png
Attachment 3: run134_Mugast_1_6.png
run134_Mugast_1_6.png
Attachment 4: run134_Mugast_1_5.png
run134_Mugast_1_5.png
Attachment 5: run134_Mugast_1_4.png
run134_Mugast_1_4.png
Attachment 6: run134_Mugast_1_3.png
run134_Mugast_1_3.png
Attachment 7: run134_Mugast_1_2.png
run134_Mugast_1_2.png
Attachment 8: run134_Mugast_1_1.png
run134_Mugast_1_1.png
Attachment 9: run134_VAMOS_1_11.png
run134_VAMOS_1_11.png
Attachment 10: run134_VAMOS_1_10.png
run134_VAMOS_1_10.png
Attachment 11: run134_VAMOS_1_9.png
run134_VAMOS_1_9.png
Attachment 12: run134_VAMOS_1_8.png
run134_VAMOS_1_8.png
Attachment 13: run134_VAMOS_1_7.png
run134_VAMOS_1_7.png
Attachment 14: run134_VAMOS_1_6.png
run134_VAMOS_1_6.png
Attachment 15: run134_VAMOS_1_5.png
run134_VAMOS_1_5.png
Attachment 16: run134_VAMOS_1_4.png
run134_VAMOS_1_4.png
Attachment 17: run134_VAMOS_1_2.png
run134_VAMOS_1_2.png
Attachment 18: run134_scaler_14h00.png
run134_scaler_14h00.png
Fixede786s Mon Jun 24 13:57:46 2019 FreddyGRITHardwareCryo-3HeTiming change: -50 ns on CATS stop
We removed 50 ns of delay to the CATS signal used for the stop of the TOF (CATS-MUGAST/MUST) because we were at the edge of the FAG.
See the attached picture for the current situation:
Green: MUGAST/MUST2 ORD
Pink: FAG
yellow: CATS2
blue: CATS validated by FAG
Attachment 1: TimingCATSMUGAST.jpg
TimingCATSMUGAST.jpg
Fixede786s Mon Jun 24 20:39:54 2019 FreddyRUNGeneralCryo-3Herun 56 screenshots
Attachment 1: scalers_run55_24062019_20h37.png
scalers_run55_24062019_20h37.png
Fixede786s Wed Jun 26 03:46:09 2019 FreddyRUNGeneralCryo-3HeRun 58 -screenshots
Screenshots at 3h30 on the 26th of june during RUN 58
Attachment 1: run58_CATS_26062019_3h39.png
run58_CATS_26062019_3h39.png
Attachment 2: run58_Correl_26062019_3h39.png
run58_Correl_26062019_3h39.png
Attachment 3: run58_TAC_26062019_3h39.png
run58_TAC_26062019_3h39.png
Attachment 4: run58_MGdETOF_26062019_3h39.png
run58_MGdETOF_26062019_3h39.png
Attachment 5: run58_MGImpact_26062019_3h39.png
run58_MGImpact_26062019_3h39.png
Attachment 6: run58_MMImpact_26062019_3h39.png
run58_MMImpact_26062019_3h39.png
Fixede786s Wed Jun 26 03:55:20 2019 FreddyOFFLINEGeneralN/ARun conversion with AGATA
To convert a run including the AGATA data, here is the procedure (Only if you know reasonably what you are doing Wink

1- Go to the AGATA Analysis computer, open a terminal and execute the following commands:

> a4
> t e786s
> cd Replay
> ./do_global_replay.sh -run ## (## is the run number you want to convert)

2- When it is finished copy the root file to the GANIL world:

> mkdir /dataganil/e786s/acquisition/root_agata/run_00##/
> cp ./run_00##/Out/Analysis/Tree_00*.root /dataganil/e786s/acquisition/root_agata/run_00##/.
Fixede786s Wed Jun 26 04:54:07 2019 FreddyAGATAGeneralN/AAGATA validation problem (solved)
Since about 4h20, we realized that AGATA validated events and timestamps have suddenly dropped on the AGATA display (yellow bars instead of green).
We checked the counting rate on MUGAST, VAMOS and FAG and there is no obvious problem on this side. Same for the MUGAST/VAMOS data on disk.

We call Emmanuel...

Problem solved by restarting entirely GTS Tree (that was broken).

Restarted at 5h37 with run 59. (it took about 30 min).
Fixede786s Wed Jun 26 05:58:23 2019 FreddyOFFLINEGeneralN/AOffline analysis run 56 and 58
Attachment 1: run56-58_analysis.png
run56-58_analysis.png
Attachment 2: run56-59_analysis_gammarays.png
run56-59_analysis_gammarays.png
Attachment 3: run56_analysis.png
run56_analysis.png
Attachment 4: run58_analysis.png
run58_analysis.png
Fixede786s Wed Jun 26 07:01:00 2019 FreddyAGATAGeneralN/AAGATA validation problem - again - during run 59
30 min after Emmanuel left (around 6h00), the AGATA problem of validation reappeared...

TO BE SOLVED....
Fixede786s Wed Jun 26 07:04:06 2019 FreddyCATSGeneralN/AUpdate of CATS calibrations
New calibrations in :
/home/mugast/analysis/nptool/Projects/calibration/cats/CATS2_X.vamos2019_e786s.npt
/home/mugast/analysis/nptool/Projects/calibration/cats/CATS2_X.vamos2019_e786s.npt

Calibration.txt was modified accordingly.
Attached are the CATS positions for run 56 and 58 (after the central strip problem)
Attachment 1: run56_cats_newcal.png
run56_cats_newcal.png
Attachment 2: run_58_cats_newcal.png
run_58_cats_newcal.png
Fixede786s Fri Jun 28 08:54:50 2019 FreddyRUNGeneralCryo-3Herun 74

Daniele Mengoni wrote:
screenshots run 74 attached

frequent error message on the FP DC Wi1 --> defqlt. The elog said so, card tripped, but spectra are still present .. puzzling




Put the voltage back at 8h00 when i arrived.
Fixede786s Fri Jun 28 08:57:21 2019 FreddyCATSGeneralCryo-3HeCATS scaler not compatible with beam rate
The CATS scaler si now around 100-120 kHz while the beam rate is still 40 kHz.

I checked the CATS signal and there is clearly noise who induce double logic signals. Not all of them are validated by FAG.

We should raise the threshold- call sebastien

9h32 : Stop beam to enter and raise the threshold.
Attachment 1: ScalerCATSproblem.png
ScalerCATSproblem.png
Fixede768s Thu Jul 25 17:19:52 2019 FreddyOFFLINEGeneralN/AScaler evolution + scaler file reader
Attached is a plot of several scaler (frequency as a function of time) for all data from run 120 to 140.

A software was written to process the scaler.dat files and is located in:
~/analysis/scalereader/

you can find an example of how to execute it in:
~/analysis/scalereader/exe.sh
Attachment 1: ScalerDisplay_r120_140.png
ScalerDisplay_r120_140.png
Fixede768s Sat Jul 27 04:50:45 2019 FreddyOFFLINEGeneralN/AScaler summary since r120
run 120 - 152

/home/mugast/analysis/scalereader/out/Chain.C
Attachment 1: scaler_update.png
scaler_update.png
Fixede768s Sat Jul 27 11:49:40 2019 FreddyS1HardwareN/AAnnular degradation
I posted a detailed entry during the night about the evolution of the annular detector but it was deleted somehow...

Signals on 3-4 segments were entirely lost between run 139 and 140. It creates a lot of holes on the impact matrix.

An increase of leakage current from 0.2 to 1.4uA occurred at about the same moment:

*Wed Jul 24 21:44:44 2019 --> 0.2 uA
*Thu Jul 25 06:53:15 2019 --> 0.6 uA
*Thu Jul 25 13:23:48 2019 --> 1.4 uA
*Thu Jul 25 22:25:35 2019 --> 1.3 uA
*Fri Jul 26 07:26:23 2019 --> 1.9 uA

Screenshots about this issues are in the e768s screenshot folder.

Edit : Adding some related files from the folder, not sure if the good ones (Sylvain)
Attachment 1: annular_diag_run139_0.pdf
annular_diag_run139_0.pdf
Attachment 2: annular_diag_run140_0.pdf
annular_diag_run140_0.pdf
Attachment 3: annular_diag_run149_0.pdf
annular_diag_run149_0.pdf
Attachment 4: annular_diag_run152_0.pdf
annular_diag_run152_0.pdf
Attachment 5: HV7.pdf
HV7.pdf
Fixed  Mon Feb 24 08:46:15 2020 FreddyOFFLINEGeneralCD2r116 - check GATCONF
After a quick offline check, it seems that we get MUGAST data only if MUGAST has triggered (GATCONFMASTER = 1,2,4).

In the de/TOF spectra the different structure in time are thus not due to different timing between VAMOS and MG triggers.
Attachment 1: r116_GATCONFMASTER.png
r116_GATCONFMASTER.png
Attachment 2: r116_DSSDE_GATCONFMASTER.png
r116_DSSDE_GATCONFMASTER.png
Fixed  Fri Apr 12 02:05:34 2019 François, Chloé TARGETGeneral Target change
Changed from Target 1 hole to Target 2 (104microns).
Fixede744s Fri Apr 12 04:13:49 2019 François, ChloéOTHERHardware TAC to do list
TAC of
- MUGAST-HF : HFvalidated is suspected to come every 200ns after MUGAST, it suggests to go to a range of 500ns
- T_SI_CATS1 : CAST1 stop comes before T_SI start (roughly 100ns to be delayed)
Fixede768s Thu Jul 25 03:58:19 2019 François et GilbertRUNGeneralLiFSpectra Run 135 25/07/19 4:00
Second snapshot of run 135
Spectra refreshed
Attachment 1: Scalers_run135b
Attachment 2: MG_TOF_run135b
Attachment 3: MM_deE_run135b
Attachment 4: MM_ETOF_run135b
Attachment 5: MG_IMPACT_run135b
Attachment 6: MG_ETOF_run135b
Fixede768s Mon Jul 22 14:45:34 2019 François D, FranckBEAMGeneralLiFBeam profile
Intensity = 1.3e7 pps

Beam position shift compared to this morning 8:30

x: -1.8 mm
y: +3.3 mm
Attachment 1: Beam_profile_run125_22July2019_14h39.jpg
Beam_profile_run125_22July2019_14h39.jpg
Fixede744s Mon Apr 8 15:17:28 2019 FrançoisTARGETGeneral E744 Targets

Targets mounted on holder

N°1 Hole Diam=7 mm
N°2 CH2 104 µm => 9.67 mg/cm2 (polyethylene density = 0.93 g/cm3) Georges@2018
N°3 CH2 100 µm Goodfellow (polyethylene)
N°4 Carbon 75 µm => 6.75 < thick < 9.75 mg/cm2 (Graphite flexible, density 0,9-1,3 g/cm3) Goodfellow
N°5 CH2 73 µm Georges@2019
N°6 CH2 104 µm Georges@2019
Attachment 1: 20190408_143035.jpg
20190408_143035.jpg