Fixed | e744s |
Tue Apr 16 14:13:17 2019 |
Freddy | RUN | General | CH2 | Log and scalers RUN 134 @ 14h13 | |
18x |
Fixed | e786s |
Mon Jun 24 13:57:46 2019 |
Freddy | GRIT | Hardware | Cryo-3He | Timing change: -50 ns on CATS stop | We removed 50 ns of delay to the CATS signal
used for the stop of the TOF (CATS-MUGAST/MUST)
because we were at the edge of the FAG.
|
|
Fixed | e786s |
Mon Jun 24 20:39:54 2019 |
Freddy | RUN | General | Cryo-3He | run 56 screenshots | |
|
Fixed | e786s |
Wed Jun 26 03:46:09 2019 |
Freddy | RUN | General | Cryo-3He | Run 58 -screenshots | Screenshots at 3h30 on the 26th of june during
RUN 58 |
6x |
Fixed | e786s |
Wed Jun 26 03:55:20 2019 |
Freddy | OFFLINE | General | N/A | Run conversion with AGATA | To convert a run including the AGATA data,
here is the procedure (Only if you know reasonably
what you are doing ;-)
|
|
Fixed | e786s |
Wed Jun 26 04:54:07 2019 |
Freddy | AGATA | General | N/A | AGATA validation problem (solved) | Since about 4h20, we realized that AGATA validated
events and timestamps have suddenly dropped
on the AGATA display (yellow bars instead |
|
Fixed | e786s |
Wed Jun 26 05:58:23 2019 |
Freddy | OFFLINE | General | N/A | Offline analysis run 56 and 58 | |
   |
Fixed | e786s |
Wed Jun 26 07:01:00 2019 |
Freddy | AGATA | General | N/A | AGATA validation problem - again - during run 59 | 30 min after Emmanuel left (around 6h00),
the AGATA problem of validation reappeared...
|
|
Fixed | e786s |
Wed Jun 26 07:04:06 2019 |
Freddy | CATS | General | N/A | Update of CATS calibrations | New calibrations in :
/home/mugast/analysis/nptool/Projects/calibration/cats/CATS2_X.vamos2019_e786s.npt
/home/mugast/analysis/nptool/Projects/calibration/cats/CATS2_X.vamos2019_e786s.npt
|
 |
Fixed | e786s |
Fri Jun 28 08:54:50 2019 |
Freddy | RUN | General | Cryo-3He | run 74 | [quote="Daniele Mengoni"]screenshots run 74
attached
|
|
Fixed | e786s |
Fri Jun 28 08:57:21 2019 |
Freddy | CATS | General | Cryo-3He | CATS scaler not compatible with beam rate | The CATS scaler si now around 100-120 kHz
while the beam rate is still 40 kHz.
|
|
Fixed | e768s |
Thu Jul 25 17:19:52 2019 |
Freddy | OFFLINE | General | N/A | Scaler evolution + scaler file reader | Attached is a plot of several scaler (frequency
as a function of time) for all data from
run 120 to 140.
|
|
Fixed | e768s |
Sat Jul 27 04:50:45 2019 |
Freddy | OFFLINE | General | N/A | Scaler summary since r120 | run 120 - 152
/home/mugast/analysis/scalereader/out/Chain.C |
|
Fixed | e768s |
Sat Jul 27 11:49:40 2019 |
Freddy | S1 | Hardware | N/A | Annular degradation | I posted a detailed entry during the night
about the evolution of the annular detector
but it was deleted somehow...
|
    |
Fixed | |
Mon Feb 24 08:46:15 2020 |
Freddy | OFFLINE | General | CD2 | r116 - check GATCONF | After a quick offline check, it seems that
we get MUGAST data only if MUGAST has triggered
(GATCONFMASTER = 1,2,4).
|
 |
Fixed | |
Fri Apr 12 02:05:34 2019 |
François, Chloé | TARGET | General | | Target change | Changed from Target 1 hole to Target 2 (104microns). |
|
Fixed | e744s |
Fri Apr 12 04:13:49 2019 |
François, Chloé | OTHER | Hardware | | TAC to do list | TAC of
- MUGAST-HF : HFvalidated is suspected to
come every 200ns after MUGAST, it suggests |
|
Fixed | e768s |
Thu Jul 25 03:58:19 2019 |
François et Gilbert | RUN | General | LiF | Spectra Run 135 25/07/19 4:00 | Second snapshot of run 135
Spectra refreshed |
6x |
Fixed | e768s |
Mon Jul 22 14:45:34 2019 |
François D, Franck | BEAM | General | LiF | Beam profile | Intensity = 1.3e7 pps
Beam position shift compared to this morning |
|
Fixed | e744s |
Mon Apr 8 15:17:28 2019 |
François | TARGET | General | | E744 Targets |
Targets mounted on holder
|
|