Fixedcom2019 Mon Apr 1 10:19:35 2019 OttoRunRUNGeneral3-alphaRun162
*************************
Run : 162
*************************

Start at 2019-04-01 10:19:06.538659

Run Conditions:
  • Operator: Adrien
  • Trigger: MUGAST
  • Target/Source: double face 3 alpha
  • Beam: N/A
  • Intensity:

Comment:



Stop at 2019-04-01 10:50:54.111644
Stop comment: DAS config seems strange
Fixedcom2019 Mon Apr 1 11:00:04 2019 OttoRunRUNGeneral3-alphaRun163
*************************
Run : 163
*************************

Start at 2019-04-01 10:59:50.885757

Run Conditions:
  • Operator: Adrien
  • Trigger: MUGAST
  • Target/Source: double face 3 alpha
  • Beam: N/A
  • Intensity:

Comment: restart run after running fsc config



Stop at 2019-04-01 14:54:39.130308
Stop comment: some warning in narval
Fixedcom2019 Mon Apr 1 19:53:09 2019 OttoRunRUNGeneral3-alphaRun165
*************************
Run : 165
*************************

Start at 2019-04-01 19:52:02.219719

Run Conditions:
  • Operator: Marlene
  • Trigger: 3 first entries of GMT
  • Target/Source: alpha
  • Beam: N/A
  • Intensity:

Comment: 3 alpha source calibration with all detectors


Stop at 2019-04-02 09:02:53.007743
Stop comment:
Fixedcom2019 Tue Apr 2 08:52:16 2019 FreddyMUST2General3-alphaPEDESTAL save - run 165
Normalized Pedestal value loaded in DAS for run 165 (3-alpha)

folder: /home/mugast/ganacq_manip/mugast/das-save/pedestal-save/run165

NB: Not sure when this pedestal values were read from the board, in principle should have been read just before the run.
Fixedcom2019 Tue Apr 2 09:08:05 2019 OttoRunRUNGeneral3-alphaRun166
*************************
Run : 166
*************************

Start at 2019-04-02 09:07:03.468248

Run Conditions:
  • Operator: Freddy
  • Trigger: 3 first entries of GMT
  • Target/Source: alpha
  • Beam: N/A
  • Intensity:

Comment: 3 alpha source calibration with all detectors without pedestal subtraction to check their alignment


Stop at 2019-04-02 09:13:46.822878
Stop comment:
Attachment 1: 2019_04_02_run165_3alphas_w_and_wo_pedestals.png
2019_04_02_run165_3alphas_w_and_wo_pedestals.png
Fixede744s Thu Apr 18 09:28:12 2019 MarlèneMUST2General3-alphaRUN 206 (mugast) 3Alpha calib after e744s experiment
RUN 206
3 alpha source all detectors with no change in the configuration (low thresholds in MUST2)
From 17/04 18h13 -> 18/04 9h31
Attachment 1: run206_calibMMY.png
run206_calibMMY.png
Attachment 2: run206_calibMGY.png
run206_calibMGY.png
Attachment 3: run206_calibMMX.png
run206_calibMMX.png
Attachment 4: run206_calibMGX.png
run206_calibMGX.png
FixedTEST Mon May 27 16:17:48 2019 OttoRunRUNGeneral3-alphaRun229
*************************
Run : 229
*************************

Start at 2019-05-27 16:17:16.001351

MUGAST alpha run no pedestal supression

test run qfter restarting system. temp is still qround 15deg

Stop at 2019-05-27 16:50:50.508660
Stop comment: source was not in correct position

EDIT: there is no data for this run; the entry was create because the scaler storage was on.

Stop at 2019-05-27 19:09:53.235957
Stop comment: type your message here

Stop at 2019-05-27 19:31:47.881701
Stop comment: type your message here
FixedTEST Tue May 28 10:43:58 2019 OttoRunRUNGeneral3-alphaRun229
*************************
Run : 229
*************************

Start at 2019-05-28 10:43:42.122755

MUGAST alpha run no pedestal supression

test run after restarting system. temp is still around 5deg

Stop at 2019-05-28 14:47:46.808600
Stop comment: type your message here

Stop at 2019-05-28 15:22:40.074144
Stop comment: type your message here

Stop at 2019-05-28 15:57:47.785333
Stop comment: type your message here

Stop at 2019-05-28 16:59:06.325170
Stop comment: type your message here

Stop at 2019-05-28 17:14:12.527918
Stop comment: type your message here

Stop at 2019-05-28 17:34:19.526635
Stop comment:

Stop at 2019-05-28 17:52:55.515837
Stop comment: type your message here

Stop at 2019-05-28 18:17:09.389775
Stop comment: type your message here
FixedTEST Tue May 28 11:08:10 2019 mugastMUST2Hardware3-alphaMG3 is tripping
MG3T is tripping, tryied to set max current to 20uA but it still trip around 30V.
FixedTEST Thu May 30 15:42:13 2019 OttoRunRUNGeneral3-alphaRun229
*************************
Run : 229
*************************

Start at 2019-05-30 15:41:17.803744

MUGAST alpha run pedestal supression
temperature -3 deg (trap) & -4 deg (must2) consigne 5 deg

Stop at 2019-05-30 15:49:50.743195
Stop comment: type your message here
FixedTEST Thu May 30 15:55:15 2019 OttoRunRUNGeneral3-alphaRun229
*************************
Run : 229
*************************

Start at 2019-05-30 15:54:16.275808

MUGAST 3alpha run pedestal supression
temperature -3 deg (trap) & -4 deg (must2) consigne 5 deg

no pedestal suppression (but alignement)
Unsual bias for MG4T =130V, I=4 uA because no trigger on Y.

Stop at 2019-05-30 15:57:43.637854
Stop comment: type your message here
FixedTEST Thu May 30 15:58:20 2019 OttoRunRUNGeneral3-alphaRun230
*************************
Run : 230
*************************

Start at 2019-05-30 15:57:54.390230

MUGAST 3alpha run pedestal supression
temperature -3 deg (trap) & -4 deg (must2) consigne 5 deg

no pedestal suppression (but alignement)
Unsual bias for MG4T =130V, I=4 uA because no trigger on Y.

same as before except that MG7 had a mate hidden on Y (now it is on)

Stop at 2019-05-30 15:59:04.950841
Stop comment: type your message here

Stop at 2019-05-30 16:01:48.801380
Stop comment:
FixedTEST Thu May 30 16:04:09 2019 OttoRunRUNGeneral3-alphaRun230
*************************
Run : 230
*************************

Start at 2019-05-30 16:04:07.241232

MUGAST 3alpha run pedestal supression
temperature -3 deg (trap) & -4 deg (must2) consigne 5 deg

no pedestal suppression (but alignement)
Unsual bias for MG4T =130V, I=4 uA because no trigger on Y.

same as before except that MG7 had a mate hidden on Y (now it is on)

Stop at 2019-05-30 16:06:21.092742
Stop comment: type your message here
FixedTEST Thu May 30 16:08:39 2019 OttoRunRUNGeneral3-alphaRun230
*************************
Run : 230
*************************

Start at 2019-05-30 16:08:37.332238

MUGAST 3alpha run pedestal supression
temperature -3 deg (trap) & -4 deg (must2) consigne 5 deg

no pedestal suppression (but alignement)
Unsual bias for MG4T =130V, I=4 uA because no trigger on Y.

same as before except that MG7 had a mate hidden on Y (now it is on)

Stop at 2019-05-30 16:09:38.806154
Stop comment: type your message here
FixedTEST Thu May 30 16:10:18 2019 OttoRunRUNGeneral3-alphaRun230
*************************
Run : 230
*************************

Start at 2019-05-30 16:09:44.953775

MUGAST 3alpha run pedestal supression
temperature -3 deg (trap) & -4 deg (must2) consigne 5 deg

no pedestal suppression (but alignement)
MG4T =95V

same as before except that MG7 had a mate hidden on Y (now it is on)

Stop at 2019-05-31 06:39:11.358615
Stop comment: type your message here
Attachment 1: run229_3lapha_mugast_calibre.png
run229_3lapha_mugast_calibre.png
Attachment 2: run229_3alpha_must2.png
run229_3alpha_must2.png
Attachment 3: run229_3alpha.png
run229_3alpha.png
FixedTEST Tue Jun 11 18:59:36 2019 OttoRunRUNGeneral3-alphaRun231
*************************
Run : 231
*************************

Start at 2019-06-11 18:58:31.909158

MUGAST 3alpha run pedestal supression
temperature -1 deg (trap) & -4 deg (must2) consigne 5 deg

no pedestal suppression (but alignement)

alpha source in front of cryogenic target, NOT AT TARGET POSITION !!!

Stop at 2019-06-11 21:40:22.107913
Stop comment:
FixedTEST Tue Jun 11 21:44:38 2019 OttoRunRUNGeneral3-alphaRun232
*************************
Run : 232
*************************

Start at 2019-06-11 21:44:02.397316

MUGAST 3alpha run pedestal supression
temperature -1 deg (trap) & -4.5 deg (must2) consigne 5 deg

with pedestal suppression

alpha source in front of cryogenic target, NOT AT TARGET POSITION !!!

Stop at 2019-06-12 10:05:20.279209
Stop comment: type your message here
FixedTEST Wed Jun 12 18:40:57 2019 OttoRunRUNGeneral3-alphaRun233
*************************
Run : 233
*************************

Start at 2019-06-12 18:40:34.500264

MUGAST 3alpha run pedestal supression
temperature -1 deg (trap) & -4.5 deg (must2) consigne 5 deg

without pedestal suppression

alpha source in front of cryogenic target, NOT AT TARGET POSITION !!!

Stop at 2019-06-13 09:06:36.277090
Stop comment:
FixedTEST Thu Jun 13 09:46:40 2019 OttoRunRUNGeneral3-alphaRun234
*************************
Run : 234
*************************

Start at 2019-06-13 09:45:49.383074

Discard run
alpha source in front of cryogenic target, NOT AT TARGET POSITION !!!

Stop at 2019-06-13 09:47:06.006149
Stop comment: Discard this run
FixedTEST Thu Jun 13 09:47:39 2019 OttoRunRUNGeneral3-alphaRun235
*************************
Run : 235
*************************

Start at 2019-06-13 09:47:19.893278

Discard run
alpha source in front of cryogenic target, NOT AT TARGET POSITION !!!

Stop at 2019-06-13 14:23:23.430392
Stop comment: type your message here