Fixed, e768s, Tue Jul 23 00:01:23 2019, Freddy, Jenn, BEAM, General, LiF, Beam intensity and profile check 
|
|
Fixed, e768s, Tue Jul 23 02:04:17 2019, Freddy, Jenn, OTHER, General, LiF, overnight summary (Monday 22 to Tuesday 23rd)
|
Smooth counting at 1000 KHz in VAMOS (see scalers)
- 1h45 - resync of AGATA 13C |
Fixed, e768s, Tue Jul 23 02:09:38 2019, Freddy, Jenn, OFFLINE, General, LiF, Ex-Egamma (update)
|
Ex Egamma for run 112 115 116 117 118 119 120 121 122 124 125 126(partial) |
Fixed, e768s, Tue Jul 23 02:15:58 2019, Freddy, Jenn, ONLINE, General, LiF, Screenshots run 126 @2h00 20x
|
|
Fixed, TEST, Mon Feb 24 16:11:05 2020, Freddy, Franco, Didier, Marlène, RUN, General, , run 123 screenshots    
|
RUN 123
CD2 300ug/cm2
Beam intensity 1e5 pps
|
Fixed, e786s, Sun Jun 23 14:37:43 2019, Freddy, Franco and Louis, OTHER, Hardware, , Temperature error on +2.5v/t3
|
There is a temperature error on the +2.5 V for MUST2 Telescope. It created error message due to hv_monitor but it does not shutdown the voltage.
We modified the code in hv_monitor to not display popup message and elog message if this channel is concerned. |
Fixed, e768s, Wed Jul 31 03:22:42 2019, Freddy, Chloé, BEAM, General, , Beam profile (run160) @2h24
|
|
Fixed, e768s, Wed Jul 31 03:25:57 2019, Freddy, Chloé, BEAM, General, N/A, Scaler Evolution run 160
|
Scaler evolution during run 160 until 3h30 on Wednesday 31st.
- rather stable condition around 1.5 * 10^7 pps
|
Fixed, e768s, Wed Jul 31 04:13:31 2019, Freddy, Chloé, BEAM, General, N/A, HF CIME disjonction 
|
Disjonction HF CIME at 4h14
Restart at 4h30 (see beam profile and scalers after restart) |
Fixed, e768s, Wed Jul 31 04:56:38 2019, Freddy, Chloé, RUN, General, LiF, Screenshots run 160 - Wed31 @ 4h57 18x
|
|
Fixed, e775s, Thu Mar 5 17:07:40 2020, Freddy, Adrien, OTHER, General, N/A, Pedestals: summary for E775s 16x
|
Two runs are useful for pedestals after experiment:
run 190 --> normalized pedestals (nominally to 8192)
|
Fixed, e793s, Thu Mar 11 12:11:16 2021, Freddy Adrien, OFFLINE, General, N/A, Elastic - Fixed MM5 position
|
We roughly fixed the position of MM5 in the mugast.detector file.
Kinematic line for elastic channels are now clearly visible. |
Fixed, TEST, Thu Feb 21 09:08:49 2019, Freddy, RUN, General, 3-alpha, RUN 30 - alpha on MG 1,3,5,7   
|
[U][B]Run 30[/B][/U]
Alpha source run for trapezoid detectors during the night with pedestals aligned and zero suppression. Cooling at 15°C.
|
Pinned, TEST, Tue Feb 26 09:30:21 2019, Freddy, OTHER, Hardware, N/A, Cabling - MUVI / HT-BT / SA-SL
|
Cabling scheme - to update until final |
Fixed, TEST, Fri Mar 1 12:07:44 2019, Freddy, GRIT, General, 3-alpha, Efficiency reconstruction  
|
blue: reconstructed efficiency using alpha run 40 (arbitratily normalized)
red: simulated efficiency
|
Fixed, com2019, Tue Apr 2 08:52:16 2019, Freddy, MUST2, General, 3-alpha, PEDESTAL save - run 165
|
Normalized Pedestal value loaded in DAS for run 165 (3-alpha)
folder: /home/mugast/ganacq_manip/mugast/das-save/pedestal-save/run165
|
Fixed, com2019, Tue Apr 2 17:15:47 2019, Freddy, OTHER, General, N/A, DWBA Cross section
|
16O(d,p)17O*(1/2+) @ 6 MeV/nucleon - SF = 1 |
Fixed, com2019, Thu Apr 4 16:30:53 2019, Freddy, RUN, General, N/A, Time Calibrator Run Summary
|
[B]RUN 150-157[/B]
pedestal file loaded : /home/mugast/ganacq_manip/das-save/pedestal-save/pedestal_read_3april_15h18
|
Fixed, e744s, Mon Apr 15 01:06:57 2019, Freddy, BEAM, General, N/A, Dipole trip
|
A dipole tripped somewhere on the line, the operators put it back to value very quickly. Interruption of the beam for 2 minutes at 1h06. |
Fixed, e744s, Mon Apr 15 01:49:49 2019, Freddy, MUST2, General, N/A, CsI - low energy suppression
|
The suppression zone around the pedestals for the CsI was set to 8210 since the beginning of the experiment.
It corresponds to about 30 channels above the zero (8192). The gain for the CsI is of 40 keV/channel.
|
|