MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 118 of 132  Not logged in MUGAST
Status ExpNbr Date Author Type Categorydown Target-Source Subject
Fixede775s Wed Feb 26 20:41:21 2020 Nicolas, SylvainRUNGeneral run 138
Start at 15h45 (Feb. 26th)
Stop at 09h48 (Feb. 27th)

Beam: 19O
Intensity: 4e5 pps

Target; CD2 + Au #2
Fixede775s Wed Feb 26 20:45:14 2020 Nicolas, SylvainRUNGeneral run 138 - minutes of what happened during the run
Here is a brief summary of what happened over the course of the run:

From 4 pm to 12 pm (February 26th)
1. 20h00: call PCP because beam intensity decreased smoothly from 4e5 pps (16h) to 3e5 pps (20h) -> back to 3.5e5 pps
2. 20h25: call PCP because of sudden drop of intensity. VAMOS PF bias OK and beam OK according to PCP. Beam came back alone up to 3.2e5 pps with relaxation time of qbout 10 min as if some element was rumping up.
3. 23h50: FP_CATS tripped

From 12 pm to 8 am (February 27th)
Stable beam intensity at around 3.1e5 pps with VAMOS FP HV tripping 4 times

From 8 am to end of run (February 27th)
1. 08h05: FP_CATS0..5 tripped
2. 08h50: FP_CATS0..5 tripped


Nicolas, Sylvain wrote:
Start at 15h45
Stop at

Beam: 19O
Intensity: 4e5 pps

Target; CD2 + Au #2
Fixede775s Wed Feb 26 21:57:05 2020 Nicolas, SylvainRUNGeneral run 138 screenshots1

Nicolas, Sylvain wrote:
Start at 15h45
Stop at

Beam: 19O
Intensity: 4e5 pps

Target; CD2 + Au #2
Attachment 1: RUN138_scalers.png
RUN138_scalers.png
Attachment 2: RUN138_ThetaLab_ELab.png
RUN138_ThetaLab_ELab.png
Attachment 3: RUN138_impact.png
RUN138_impact.png
Attachment 4: RUN138_TAC.png
RUN138_TAC.png
Attachment 5: RUN138_ToF.png
RUN138_ToF.png
Fixede775s Thu Feb 27 03:13:33 2020 Faïrouz, Chloé & MichalRUNGeneral run 138 screenshots1 at 03:13

Faïrouz, Chloé, Michal wrote:

Faïrouz, Chloé, Michal wrote:
Screen shots at 03:15 am

Beam: 19O
Intensity: 3.4e5 pps

Target; CD2 + Au #2
Attachment 1: Scalers-run138-2020-02-27-03-08-33.png
Scalers-run138-2020-02-27-03-08-33.png
Attachment 2: MG-impact-matrix-2020-02-27_03-10-04.png
MG-impact-matrix-2020-02-27_03-10-04.png
Attachment 3: MG_Theta_E-2020-02-27_03-10-38.png
MG_Theta_E-2020-02-27_03-10-38.png
Attachment 4: TACS-2020-02-27_03-11-13.png
TACS-2020-02-27_03-11-13.png
Attachment 5: MG-E-TOF-2020-02-27_03-12-30.png
MG-E-TOF-2020-02-27_03-12-30.png
Attachment 6: Run-138-Ex-2020-02-27_03-17-51.png
Run-138-Ex-2020-02-27_03-17-51.png
Fixede775s Thu Feb 27 03:21:03 2020 Faïrouz, Chloé & MichalRUNGeneral run 138 screenshots at 07:20 am

Faïrouz, Chloé & Michal wrote:

Faïrouz, Chloé, Michal wrote:

Faïrouz, Chloé, Michal wrote:
Screen shots at 07:20 am

Beam: 19O
Intensity: 3.0e5 pps

Target; CD2 + Au #2
Attachment 1: Scaler-run138-2020-02-27_07-16-33.png
Scaler-run138-2020-02-27_07-16-33.png
Attachment 2: TAC-2020-02-27_07-17-16.png
TAC-2020-02-27_07-17-16.png
Attachment 3: MG-E-TOF-2020-02-27_07-17-43.png
MG-E-TOF-2020-02-27_07-17-43.png
Attachment 4: Impact-2020-02-27_07-18-17.png
Impact-2020-02-27_07-18-17.png
Attachment 5: MG-E-Theta-2020-02-27_07-18-50.png
MG-E-Theta-2020-02-27_07-18-50.png
Attachment 6: FPMW-HF-2020-02-27_07-19-39.png
FPMW-HF-2020-02-27_07-19-39.png
Attachment 7: Ex-run138-2020-02-27_08-19-27.png
Ex-run138-2020-02-27_08-19-27.png
Fixede775s Thu Feb 27 08:21:19 2020 Nicolas, SylvainRUNGeneral run 138 - Beam intensity time evolution

Nicolas, Sylvain wrote:
Start at 15h45
Stop at

Beam: 19O
Intensity: 4e5 pps

Target; CD2 + Au #2
Attachment 1: BeamIntensityProfile.png
BeamIntensityProfile.png
Attachment 2: BeamIntensityProfileNight.png
BeamIntensityProfileNight.png
Fixede775s Thu Feb 27 08:38:05 2020 Nicolas, SylvainOFFLINEGeneral run 138 - analysis

Nicolas, Sylvain wrote:
Start at 15h45
Stop at

Beam: 19O
Intensity: 4e5 pps

Target; CD2 + Au #2
Attachment 1: Ex-run138-2020-02-27_08-19-27.png
Ex-run138-2020-02-27_08-19-27.png
Attachment 2: RUN138_Ex.png
RUN138_Ex.png
Attachment 3: RUN138_ExEg.png
RUN138_ExEg.png
Fixede775s Thu Feb 27 09:54:17 2020 Nicolas, Sylvain, Antoine, AdrienRUNGeneral run 139
Start at 09h50 (Feb. 27th)
Stop at

Beam: 19O
Intensity: 3e5 pps

Target; CD2 + Au #2
Fixede775s Thu Feb 27 09:56:19 2020 Nicolas, Sylvain, Antoine, AdrienRUNGeneral run 139 - analysis

Nicolas, Sylvain, Antoine, Adrien wrote:
Start at 09h50 (Feb. 27th)
Stop at

Beam: 19O
Intensity: 3e5 pps

Target; CD2 + Au #2
Fixede775s Thu Feb 27 09:56:39 2020 Nicolas, Sylvain, Antoine, AdrienRUNGeneral run 139 - Beam intensity time evolution

Nicolas, Sylvain, Antoine, Adrien wrote:
Start at 09h50 (Feb. 27th)
Stop at

Beam: 19O
Intensity: 3e5 pps

Target; CD2 + Au #2
Fixede775s Thu Feb 27 10:03:03 2020 Nicolas, Sylvain, Antoine, AdrienRUNGeneral run 139 - minutes of what happened during the run
Here is a brief summary of what happened over the course of the run:

From beginning of run to 12 pm (February 27th)



Nicolas, Sylvain, Antoine, Adrien wrote:
Start at 09h50 (Feb. 27th)
Stop at

Beam: 19O
Intensity: 3e5 pps

Target; CD2 + Au #2
Fixede775s Thu Feb 27 11:51:34 2020 Nicolas Sylvain MarlèneRUNGeneral run 139
Start at 09h51 (Feb. 27th)
Stop at 11h22 (Feb. 27th)

Beam: 19O
Intensity: 3e5 pps

Target; CD2 + Au #2
Fixede775s Thu Feb 27 11:53:34 2020 mugastRUNGeneral run 140
Start at 11h41 (Feb. 27th)
Stop at (Feb. 27th)

Beam: 19O
Intensity: 4e5 pps

Target; CD2 (350 ug/cm2, NO gold) #3
Fixede775s Thu Feb 27 12:35:39 2020 Marlène NicolasGRITGeneral RUN128-137_138 analysis
Kinematic lines for the full statistics up to now
States above E*>7 MeV are cut in the angles >140 because of energy threshold.
Attachment 1: Elab_Thetalab_RUN128_137_138.png
Elab_Thetalab_RUN128_137_138.png
Attachment 2: ExEg_RUN128_137_139.png
ExEg_RUN128_137_139.png
Attachment 3: Ex_RUN128_137_138.png
Ex_RUN128_137_138.png
Fixede775s Thu Feb 27 15:51:03 2020 mugastRUNGeneral RUN 140
Target CD2 thin target
Beam intensity ~ 5e+5 pps


to check the gammas from 20O
Fixed  Thu Feb 27 15:54:09 2020 Marlène RUNGeneral RUN 141 junk (problem at start)
Fixed  Thu Feb 27 15:56:09 2020 MarlèneRUNGeneral RUN 142 AGATA- 143 VAMOS-MUGAST
RUN142 on AGATA and RUN143 on MUGAST/VAMOS

target CD2 (350ug/cm2)
Trigger MUGAST
Beam intensity : 5e+5pps



!!!! there is a shift in the run number on AGATA with respect to VAMOS/MUGAST
Fixed  Thu Feb 27 16:25:45 2020 MarlèneRUNGeneral RUN 142-143 screenshots

Marlène wrote:
RUN142 on AGATA and RUN143 on MUGAST/VAMOS

target CD2 (350ug/cm2)
Trigger MUGAST
Beam intensity : 5e+5pps



!!!! there is a shift in the run number on AGATA with respect to VAMOS/MUGAST
Attachment 1: RUN143_ElabThetaLab.png
RUN143_ElabThetaLab.png
Attachment 2: RUN143_impact.png
RUN143_impact.png
Attachment 3: RUN143_tac.png
RUN143_tac.png
Attachment 4: RUN143_tof.png
RUN143_tof.png
Fixed  Thu Feb 27 16:30:53 2020 MarlèneRUNGeneral RUN 142 -143 preliminary analysis

Marlène wrote:

Marlène wrote:
RUN142 on AGATA and RUN143 on MUGAST/VAMOS

target CD2 (350ug/cm2)
Trigger MUGAST
Beam intensity : 5e+5pps



!!!! there is a shift in the run number on AGATA with respect to VAMOS/MUGAST
Attachment 1: RUN143_ana_Elab_Thetalab.png
RUN143_ana_Elab_Thetalab.png
Attachment 2: RUN143_ana_Ex_Eg.png
RUN143_ana_Ex_Eg.png
Attachment 3: RUN143_ana_Ex.png
RUN143_ana_Ex.png
Fixede775s Thu Feb 27 16:36:25 2020 Nicolas Sylvain MarlèneRUNGeneral run 139

Nicolas Sylvain Marlène wrote:
Start at 09h51 (Feb. 27th)
Stop at 11h22 (Feb. 27th)

Beam: 19O
Intensity: 3e5 pps

Target; CD2 + Au #2



temperature on MUFEE was checked to be between 0 and 12 degress depending on the boards.
The current of the detectors are stable.

ELOG Home Page