MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 116 of 132  Not logged in MUGAST
Fixed, e768s, Fri Jul 19 00:03:25 2019, Jenn, BEAM, General, , Brho information 15 Oxygen beam 4.7MeV/u 
Fixed, e768s, Fri Jul 19 00:06:35 2019, Jenn, BEAM, General, , Brho information 15 Oxygen beam 4.7MeV/u New_Doc_2019-07-18_23.58.18_1.pdf
Fixed, e768s, Fri Jul 19 03:29:58 2019, Jenn, ONLINE, General, LiF, Screenshots run 112 overnight 16x
MUGAST and VAMOS screenshots run 112
Fixed, e768s, Mon Jul 29 01:27:59 2019, Jenn, BEAM, General, LiF, Beam intensity and profile check photo_2019-07-29_00-27-36.jpg
Run number 156: 15-O beam
beam intensity 8.8e6
OR Vamos ~ 106
Fixed, e768s, Mon Jul 15 18:05:14 2019, Iulian, Serge, RUN, General, N/A, Run7 - TAC calibration 
*************************
Run : 7
*************************

Start at 2019-07-15 18:04:51.105052

TAC Time calibrator

range 2.56 um
period 20ns


TACs range settings:
1. VAMOS - AGATA -> 500 ns
2. FAG - HF -> 200 ns
3. CATAS1 - HF -> 500 ns
4. VAMOS - HF -> 2 us
5. MUGAST - VAMOS -> 2 us
6. MUST2 - AGATA -> 2 us
7. MUST2 - HF -> 2 us
8. BAF2 - HF -> 1 us
9. AGATA - HF -> 200 ns

Stop at 2019-07-15 18:16:11.458928
Stop comment: Finish 1st time calibration. Changing ranges now
Fixed, e768s, Mon Jul 15 18:17:49 2019, Iulian, Serge, RUN, General, N/A, Run8 - TAC calibrations 
*************************
Run : 8
*************************

Start at 2019-07-15 18:17:21.942994

TAC Time calibrator

range 2.56 um

10 ns period
Fixed, e768s, Mon Jul 15 18:39:03 2019, Iulian, Serge, RUN, General, N/A, Run9 - TAC calibration 
*************************
Run : 9
*************************

Start at 2019-07-15 18:38:59.133455

TAC Time calibrator

range 2.56 um

10 ns period

Stop at 2019-07-15 19:04:03.255467
Stop comment: type your message here

Stop at 2019-07-15 19:18:09.593144
Stop comment: end of tac time calibration
Fixed, com2019, Sat Apr 6 02:48:39 2019, Iulian Ruxandra, RUN, Software, , Online Spectra run 256 @2h30 am 06/04 (for reference) 11x
The online spectra (for reference)
No timing on Mg3 & Mg4 side X. Those correspond with the masked channels on the Muvi1
Fixed, com2019, Sat Apr 6 02:52:51 2019, Iulian Ruxandra, RUN, Software, , Online Scalers run 256 @2h30 am 06/04 for reference Run_256_Scaler1.pngRun_256_Scaler2.pngRun_256_Scaler3.pngRun_256_Scaler4.png
Fixed, com2019, Sat Apr 6 03:22:30 2019, Iulian Ruxandra, RUN, Software, , New Kinematics plots (4h of stats) Kine256_0-256_3.pdfKine256_0-256_3_comparison.pdfElab_vs_ThetaLab_backward.pdf
More statistics on the script written by Adrian and Valerian (first image)

Second image is a comparison between the excited states produced between 90-130 deg and 130-180 deg. Effects of angular distribution?


the kinematic line seen in the Elab vs Theta at backward angles can be observed in figure 3. Are those protons?
Fixed, e744s, Sun Apr 14 03:30:28 2019, Iulian Iulia, OFFLINE, Social, CH2, first calculation ECM ThetaCM for gamma-P emission first_gammaP_rec.pdfAlias_iul.C
Fixed, e744s, Thu Apr 11 19:19:21 2019, Iulian Beyhan, RUN, General, N/A, Change target CH2 to no target 
Target hole is now removed -> No target
Fixed, e744s, Sun Apr 14 16:55:57 2019, Iulian Antoine , VAMOS, Hardware, CH2, rTarget change and Brho change VAMOS before run 125 for off resonance measurement 
16:30 start run 124
setting brho for next run
brho old = 0.519964
finger old = +12 mm

brho new = 0.550875
finger new = +16 mm

16:55 start run 125 with thinner CH2 target #5 for off-resonance measurement
    Fixed, e744s, Sat Apr 13 12:39:02 2019, Iulian ->Jaromir update, ONLINE, Hardware, N/A, Scalers - U2M23 must be the finger run122_doigt_is_u2m23.png
Looks like U2M_23 is in fact the beam dump (plastic finger).

This day scalers were looked at;
Tested OR_VAMOS + U2M23 = CATS2

the discrepancy is on level of 1-2% for the actual rate,
or approx 500-1000cps for TOTALS of the scalers.
Fixed, TEST, Fri Mar 29 10:00:52 2019, Iulian , VAMOS, General, N/A, GMT channel4 corresponds to VAMOS now 
Voie4 GMT = trigger Vamos
    Fixed, e744s, Sat Apr 13 10:32:59 2019, Iulian , ONLINE, General, CH2, Screenshots run 122 v3 
Is missing the scalers
Fixed, com2019, Tue Apr 2 14:46:27 2019, Iulian, OTHER, Hardware, N/A, TACs calibration 8x
TACs calibrations have been performed:
TAC offset slope

T_Cats1_2 0. 0.0250725
T_Si_Cats1 0. 0.0246678
T_Si_Vamos 0. 0.0253243
T_Si_Agata 0. 0.0251722
T_Vamos_Cats1 0. 0.0255071
T_Cats1_HF 0. 0.0111935
T_Fag_HF 0. 0.0104992
T_Vamos_Agata 0. 0.0252933
Fixed, e744s, Wed Apr 10 20:16:22 2019, Iulian, BEAM, General, N/A, 14N beam characteristics and Brho vamos setting 20190410_201051.jpg20190410_200749.jpg20190410_202255.jpg20190410_202353.jpg
Also the beam profile on gas profiler before and after inserting a peperpot
Fixed, e744s, Sun Apr 14 18:38:53 2019, Giuseppe, Mariluz, Jenn; Serge, Nishu, Didier, Simon, ONLINE, General, CH2, Log & Scalers -- Run 125 at 18:40 21x
Fixed, e744s, Sun Apr 14 20:23:50 2019, Giuseppe, Mariluz, Jenn, Serge, Nishu, Didier, Simon, ONLINE, General, CH2, Log & Scalers -- Run 125 at 20:20 21x

ELOG Home Page