Fixed, e793s, Tue Mar 16 23:57:29 2021, Charlie, RUN, General, CD2, run63 scaler graph at 00h00
|
The scaler graph had frozen at 15:45, so all of the screenshots of it since then show the same section. Refreshed graph of the last few hours attached. |
Fixed, e793s, Wed Mar 17 01:51:16 2021, Laetitia, Charlie, RUN, General, CD2, run63 screenshots at 01h35 9x
|
|
Fixed, e793s, Wed Mar 17 03:48:24 2021, Laetitia, Charlie, RUN, General, CD2, run63 screenshots at 03h45 (17/03) 9x
|
|
Fixed, e793s, Wed Mar 17 05:49:02 2021, Laetitia, Charlie, RUN, General, CD2, run 63 screenshots at 05h45 9x
|
|
Fixed, e793s, Wed Mar 17 07:18:39 2021, Laetitia, Charlie, ONLINE, General, CD2, VAMOS acquisition stopped
|
The acquisition on Vamos get stucked at 6h49. At 07:18, we stopped and started a new run (run 64) |
Fixed, e793s, Wed Mar 17 07:21:23 2021, OttoRun, RUN, General, CD2, Run64
|
*************************
[SIZE=3][B]Run : 64[/B][/SIZE]
*************************
|
Fixed, e793s, Wed Mar 17 07:25:24 2021, Laetitia, Charlie, ONLINE, General, CD2, VAMOS acquisition stopped
|
Vamos acquisition get stucked at 6h49 (with 2 Gbit). We stopped and started a new run at 07h18 (Run #64) |
Fixed, e793s, Wed Mar 17 07:52:37 2021, Laetitia, Charlie, RUN, General, CD2, run 64 screenshots at 07h45 10x
|
|
Pending, e793s, Wed Mar 17 08:03:15 2021, Laetitia, Charlie, AGATA, Hardware, CD2, Agata issue
|
There is a problem on Agata (the dewars are not being filled), and the Ge's start to warm up. The beam has been stopped at ~08h05. |
Fixed, e793s, Wed Mar 17 09:53:38 2021, Cyril, AGATA, Hardware, CD2, Agata issue
|
Agata problem has been solved, a valve was closed by mistake.
Beam returned at 9h40. |
Fixed, e793s, Wed Mar 17 10:23:44 2021, Cyril, RUN, General, CD2, run 64 screenshots at 10h05 - End of e793s 8x
|
The beam/acq has been stopped around 10h05. |
Fixed, e793s, Wed Mar 17 10:54:46 2021, OttoRun, RUN, General, CD2, Run65
|
*************************
[SIZE=3][B]Run : 65[/B][/SIZE]
*************************
|
Fixed, e793s, Wed Mar 17 11:10:49 2021, OttoRun, RUN, General, CD2, Run65
|
*************************
[SIZE=3][B]Run : 65[/B][/SIZE]
*************************
|
Fixed, e793s, Wed Mar 17 11:15:41 2021, OttoRun, RUN, General, CD2, Run65
|
*************************
[SIZE=3][B]Run : 65[/B][/SIZE]
*************************
|
Fixed, e793s, Wed Mar 17 11:27:40 2021, OttoRun, RUN, General, CD2, Run65
|
*************************
[SIZE=3][B]Run : 65[/B][/SIZE]
*************************
|
Fixed, e793s, Wed Mar 17 11:39:39 2021, OttoRun, RUN, General, CD2, Run65
|
*************************
[SIZE=3][B]Run : 65[/B][/SIZE]
*************************
|
Fixed, e793s, Wed Mar 17 19:19:05 2021, Franco, OFFLINE, General, CD2, Mugast detectors disaligned in Ex 
|
The Ex distributions gated on the different MG detectors show large differences, up to 500 keV. In the attached figure I show as an example the comparison
between two nearby detectors, MG3 and MG4.
I tried a rough alignment of the Ex by shifting it manually and setting the first main peak at Ex=0 (essentially taking MG5 as the reference, since his |
Fixed, TEST, Wed Jan 16 16:33:28 2019, Marlène, GRIT, General, 3-alpha, Status of detectors on 16/01/19 
|
MG1 has some issue with the HT cable (for the BT bias). There is a shortcut only under vacuum. We checked the connector but we have to do vacuum again to
check it. |
Ongoing, TEST, Tue Jan 22 18:52:23 2019, Valérian-Marlène, GRIT, General, 3-alpha, 3 alpha source run on MG10C & MG3T
|
3 alpha source (not centered)
MG10C and MG3T ON
MG10C is connected to MG5T HT and BT and seen on MUVI1 channel2 -> online name=MM2
|
Fixed, TEST, Wed Jan 23 09:11:26 2019, Valérian-Marlène, GRIT, General, 3-alpha, RUN9 : 3 alpha source run on MG10C & MG3T   
|
[B]RUN 9 (over night 22/01 ->23/01)[/B]
3 alpha source (not centered)
MG10C and MG3T ON
|
|